Literature DB >> 14653555

Monte Carlo modelling of external radiotherapy photon beams.

Frank Verhaegen1, Jan Seuntjens.   

Abstract

An essential requirement for successful radiation therapy is that the discrepancies between dose distributions calculated at the treatment planning stage and those delivered to the patient are minimized. An important component in the treatment planning process is the accurate calculation of dose distributions. The most accurate way to do this is by Monte Carlo calculation of particle transport, first in the geometry of the external or internal source followed by tracking the transport and energy deposition in the tissues of interest. Additionally, Monte Carlo simulations allow one to investigate the influence of source components on beams of a particular type and their contaminant particles. Since the mid 1990s, there has been an enormous increase in Monte Carlo studies dealing specifically with the subject of the present review, i.e., external photon beam Monte Carlo calculations, aided by the advent of new codes and fast computers. The foundations for this work were laid from the late 1970s until the early 1990s. In this paper we will review the progress made in this field over the last 25 years. The review will be focused mainly on Monte Carlo modelling of linear accelerator treatment heads but sections will also be devoted to kilovoltage x-ray units and 60Co teletherapy sources.

Entities:  

Mesh:

Year:  2003        PMID: 14653555     DOI: 10.1088/0031-9155/48/21/r01

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  52 in total

1.  Four-dimensional dosimetry validation and study in lung radiotherapy using deformable image registration and Monte Carlo techniques.

Authors:  Tzung-Chi Huang; Ji-An Liang; Thomas Dilling; Tung-Hsin Wu; Geoffrey Zhang
Journal:  Radiat Oncol       Date:  2010-05-29       Impact factor: 3.481

Review 2.  Accurate accumulation of dose for improved understanding of radiation effects in normal tissue.

Authors:  David A Jaffray; Patricia E Lindsay; Kristy K Brock; Joseph O Deasy; W A Tomé
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-03-01       Impact factor: 7.038

3.  Monte Carlo simulation of large electron fields.

Authors:  Bruce A Faddegon; Joseph Perl; Makoto Asai
Journal:  Phys Med Biol       Date:  2008-02-21       Impact factor: 3.609

4.  Determination of electron energy, spectral width, and beam divergence at the exit window for clinical megavoltage x-ray beams.

Authors:  D L Sawkey; B A Faddegon
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

5.  Monte Carlo study on a flattening filter-free 18-MV photon beam of a medical linear accelerator.

Authors:  Asghar Mesbahi; Farshad Seyed Nejad
Journal:  Radiat Med       Date:  2008-08-03

6.  Benchmarking of Monte Carlo simulation of bremsstrahlung from thick targets at radiotherapy energies.

Authors:  Bruce A Faddegon; Makoto Asai; Joseph Perl; Carl Ross; Josep Sempau; Jane Tinslay; Francesc Salvat
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

7.  Measurement of depth-dose of linear accelerator and simulation by use of Geant4 computer code.

Authors:  D Sardari; R Maleki; H Samavat; A Esmaeeli
Journal:  Rep Pract Oncol Radiother       Date:  2010-05-20

8.  Simulation of large x-ray fields using independently measured source and geometry details.

Authors:  D Sawkey; B A Faddegon
Journal:  Med Phys       Date:  2009-12       Impact factor: 4.071

9.  Monte Carlo modeling of a 6 and 18 MV Varian Clinac medical accelerator for in-field and out-of-field dose calculations: development and validation.

Authors:  Bryan Bednarz; X George Xu
Journal:  Phys Med Biol       Date:  2009-01-14       Impact factor: 3.609

10.  The accuracy of EGSnrc, Geant4 and PENELOPE Monte Carlo systems for the simulation of electron scatter in external beam radiotherapy.

Authors:  Bruce A Faddegon; Iwan Kawrakow; Yuri Kubyshin; Joseph Perl; Josep Sempau; Laszlo Urban
Journal:  Phys Med Biol       Date:  2009-09-24       Impact factor: 3.609

View more