Literature DB >> 30656730

SUPER: A blockwise curve-fitting method for accelerating MR parametric mapping with fast reconstruction.

Chenxi Hu1, Dana C Peters1.   

Abstract

PURPOSE: To investigate Shift Undersampling improves Parametric mapping Efficiency and Resolution (SUPER), a novel blockwise curve-fitting method for accelerating parametric mapping with very fast reconstruction.
METHODS: SUPER uses interleaved k-space undersampling, which enables a blockwise decomposition of the otherwise large-scale cost function to improve the reconstruction efficiency. SUPER can be readily combined with SENSE to achieve at least 4-fold acceleration. D-factor, a parametric-mapping counterpart of g-factor, was proposed and formulated to compare spatially heterogeneous noise amplification because of different acceleration methods. As a proof-of-concept, SUPER/SUPER-SENSE was validated using T1 mapping, by comparing them to alternative model-based methods, including MARTINI and GRAPPATINI, via simulations, phantom imaging, and in vivo brain imaging (N = 5), over criteria of normalized root-mean-squares error (NRMSE), average d-factor, and computational time per voxel (TPV). A novel SUPER-SENSE MOLLI cardiac T1 -mapping sequence with improved resolution (1.4 mm × 1.4 mm) was compared to standard MOLLI (1.9 mm × 2.5 mm) in 8 healthy subjects.
RESULTS: In brain imaging, 2-fold SUPER achieved lower NRMSE (0.04 ± 0.02 vs. 0.11 ± 0.02, P < 0.01), lower average d-factor (1.01 ± 0.002 vs. 1.12 ± 0.004, P < 0.001), and lower TPV (4.6 ms ± 0.2 ms vs. 79 ms ± 3 ms, P < 0.001) than 2-fold MARTINI. Similarly, 4-fold SUPER-SENSE achieved lower NRMSE (0.07 ± 0.01 vs. 0.13 ± 0.03, P = 0.02), lower average d-factor (1.15 ± 0.01 vs. 1.20 ± 0.01, P < 0.001), and lower TPV (4.0 ms ± 0.1 ms vs. 72 ms ± 3 ms, P < 0.001) than 4-fold GRAPPATINI. In cardiac T1 mapping, SUPER-SENSE MOLLI yielded similar myocardial T1 (1151 ms ± 63 ms vs. 1159 ms ± 32 ms, P = 0.6), slightly lower blood T1 (1643 ms ± 86 ms vs. 1680 ms ± 79 ms, P = 0.004), but improved spatial resolution compared with standard MOLLI in the same imaging time.
CONCLUSION: SUPER and SUPER-SENSE provide fast model-based reconstruction methods for accelerating parametric mapping and improving its clinical appeal.
© 2019 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  SUPER; SUPER-SENSE; blockwise curve-fitting; high-resolution MOLLI; model-based reconstruction; parametric mapping acceleration

Mesh:

Year:  2019        PMID: 30656730      PMCID: PMC6435434          DOI: 10.1002/mrm.27662

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  41 in total

1.  NMR relaxation times in the human brain at 3.0 tesla.

Authors:  J P Wansapura; S K Holland; R S Dunn; W S Ball
Journal:  J Magn Reson Imaging       Date:  1999-04       Impact factor: 4.813

2.  Self-calibrating parallel imaging with automatic coil sensitivity extraction.

Authors:  Charles A McKenzie; Ernest N Yeh; Michael A Ohliger; Mark D Price; Daniel K Sodickson
Journal:  Magn Reson Med       Date:  2002-03       Impact factor: 4.668

3.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

4.  Compressed sensing reconstruction for magnetic resonance parameter mapping.

Authors:  Mariya Doneva; Peter Börnert; Holger Eggers; Christian Stehning; Julien Sénégas; Alfred Mertins
Journal:  Magn Reson Med       Date:  2010-10       Impact factor: 4.668

5.  Accelerated MR parameter mapping with a union of local subspaces constraint.

Authors:  Sagar Mandava; Mahesh B Keerthivasan; Zhitao Li; Diego R Martin; Maria I Altbach; Ali Bilgin
Journal:  Magn Reson Med       Date:  2018-07-15       Impact factor: 4.668

6.  Model-based Acceleration of Parameter mapping (MAP) for saturation prepared radially acquired data.

Authors:  Johannes Tran-Gia; Daniel Stäb; Tobias Wech; Dietbert Hahn; Herbert Köstler
Journal:  Magn Reson Med       Date:  2013-01-11       Impact factor: 4.668

7.  Accelerated T2 mapping combining parallel MRI and model-based reconstruction: GRAPPATINI.

Authors:  Tom Hilbert; Tilman J Sumpf; Elisabeth Weiland; Jens Frahm; Jean-Philippe Thiran; Reto Meuli; Tobias Kober; Gunnar Krueger
Journal:  J Magn Reson Imaging       Date:  2018-02-15       Impact factor: 4.813

8.  High-resolution T1 and T2 mapping of the brain in a clinically acceptable time with DESPOT1 and DESPOT2.

Authors:  Sean C L Deoni; Terry M Peters; Brian K Rutt
Journal:  Magn Reson Med       Date:  2005-01       Impact factor: 4.668

9.  Why fat is bright in RARE and fast spin-echo imaging.

Authors:  R M Henkelman; P A Hardy; J E Bishop; C S Poon; D B Plewes
Journal:  J Magn Reson Imaging       Date:  1992 Sep-Oct       Impact factor: 4.813

10.  Improved quantitative myocardial T2 mapping: Impact of the fitting model.

Authors:  Mehmet Akçakaya; Tamer A Basha; Sebastian Weingärtner; Sébastien Roujol; Sophie Berg; Reza Nezafat
Journal:  Magn Reson Med       Date:  2014-08-07       Impact factor: 4.668

View more
  3 in total

1.  Quantitative T2 mapping using accelerated 3D stack-of-spiral gradient echo readout.

Authors:  Ruoxun Zi; Dan Zhu; Qin Qin
Journal:  Magn Reson Imaging       Date:  2020-08-27       Impact factor: 2.546

2.  Efficiency analysis for quantitative MRI of T1 and T2 relaxometry methods.

Authors:  David Leitão; Rui Pedro A G Teixeira; Anthony Price; Alena Uus; Joseph V Hajnal; Shaihan J Malik
Journal:  Phys Med Biol       Date:  2021-07-26       Impact factor: 3.609

3.  Deuterium Magnetic Resonance Imaging and the Discrimination of Fetoplacental Metabolism in Normal and L-NAME-Induced Preeclamptic Mice.

Authors:  Stefan Markovic; Tangi Roussel; Michal Neeman; Lucio Frydman
Journal:  Metabolites       Date:  2021-06-10
  3 in total