Literature DB >> 30617617

Use of computed tomography and diffusion weighted imaging in children with ventricular shunt.

Altan Gunes1, Ibrahim Halil Oncel2, Serra Ozbal Gunes3, Ahmet Ziya Birbilen4, Sahin Hanalioglu5.   

Abstract

PURPOSE: To evaluate the indications, number, and imaging results of brain computed tomography (CT) and diffusion weighted imaging (DWI) in children with ventriculoperitoneal shunt, to estimate the radiation dose, and to evaluate the effectiveness of DWI.
METHODS: This retrospectively study included 54 consecutive patients (boys/girls = 30/24, mean age, 3 ± 4.1 years) with shunt that were placed due to congenital abnormalities-hypoxic ischemic encephalopathy between January 2015 and March 2018. The presence of shunt-related complications (SRC) was assessed using clinical and neuroimaging findings, and the standard reference was accepted as the shunt revision. Size comparisons of ventricles were performed using Evans index and the frontal and occipital horn ratio, and each measurement made by the observers were compared using Bland-Altman analysis. A kappa coefficient and the intraclass correlation coefficient were calculated to assess the agreement between observers.
RESULTS: The mean number of hospital admission, number of CT scans, and DWI were 5.8, 4.8, and 1.1, respectively per patient. A significant linear correlation was observed between hospital admission and CT scans (r = 0.288, p = 0.035). The number of CT scans and the cumulative effective dose per patient were higher in patients with SRC than in those without (p < 0.001). The mortality rate due to radiation-induced neoplasia has increased by 0.33% in the study period. The inter-observer agreement was perfect or substantial for the catheter visualization, assessment of the ventricular system on DWI, and for the image quality of DWI between observers (κ = 0.704-1, p ≤ 0.001). No significant difference was found between CT and DWI in the measurements of Evans index and the frontal and occipital horn ratio (p > 0.05). Inter-observer agreements between observers were almost perfect for the Evans index and the frontal and occipital horn ratio (ICC = 0.94-0.99, p < 0.001).
CONCLUSIONS: An awareness of the use of CT in children is still inadequate and difficulties in the diagnosis of SRC probably cause the overuse of CT. DWI should be preferred in the diagnosis of SRC and the follow-up of patients. Otherwise, the increase in the prevalence of several diseases, particularly neoplasia, may be inevitable because of the over use of CT.

Entities:  

Keywords:  Diffusion weighted imaging; Radiation dose; Ventriculoperitoneal shunt

Year:  2019        PMID: 30617617     DOI: 10.1007/s00381-018-04046-3

Source DB:  PubMed          Journal:  Childs Nerv Syst        ISSN: 0256-7040            Impact factor:   1.475


  30 in total

1.  Unique clinical presentation of pediatric shunt malfunction.

Authors:  T T Lee; J Uribe; J Ragheb; G Morrison; J R Jagid
Journal:  Pediatr Neurosurg       Date:  1999-03       Impact factor: 1.162

2.  The Image Gently campaign: working together to change practice.

Authors:  Marilyn J Goske; Kimberly E Applegate; Jennifer Boylan; Priscilla F Butler; Michael J Callahan; Brian D Coley; Shawn Farley; Donald P Frush; Marta Hernanz-Schulman; Diego Jaramillo; Neil D Johnson; Sue C Kaste; Greg Morrison; Keith J Strauss; Nora Tuggle
Journal:  AJR Am J Roentgenol       Date:  2008-02       Impact factor: 3.959

3.  Converting dose-length product to effective dose at CT.

Authors:  Walter Huda; Kent M Ogden; Mohammad R Khorasani
Journal:  Radiology       Date:  2008-09       Impact factor: 11.105

4.  Age-specific effective doses for pediatric MSCT examinations at a large children's hospital using DLP conversion coefficients: a simple estimation method.

Authors:  Karen E Thomas; Bo Wang
Journal:  Pediatr Radiol       Date:  2008-04-08

5.  Strengthening the argument for rapid brain MR imaging: estimation of reduction in lifetime attributable risk of developing fatal cancer in children with shunted hydrocephalus by instituting a rapid brain MR imaging protocol in lieu of Head CT.

Authors:  K Koral; T Blackburn; A A Bailey; K M Koral; J Anderson
Journal:  AJNR Am J Neuroradiol       Date:  2012-05-03       Impact factor: 3.825

6.  Long-term outcomes of ventriculoperitoneal shunt surgery in patients with hydrocephalus.

Authors:  G Kesava Reddy; Papireddy Bollam; Gloria Caldito
Journal:  World Neurosurg       Date:  2013-02-04       Impact factor: 2.104

7.  Comparison of rapid cranial MRI to CT for ventricular shunt malfunction.

Authors:  Tehnaz P Boyle; Michael J Paldino; Amir A Kimia; Brianna M Fitz; Joseph R Madsen; Michael C Monuteaux; Lise E Nigrovic
Journal:  Pediatrics       Date:  2014-06-02       Impact factor: 7.124

8.  Rapid sequence magnetic resonance imaging in the assessment of children with hydrocephalus.

Authors:  Brent R O'Neill; Sumit Pruthi; Harmanjeet Bains; Ryan Robison; Keiko Weir; Jeff Ojemann; Richard Ellenbogen; Anthony Avellino; Samuel R Browd
Journal:  World Neurosurg       Date:  2012-10-27       Impact factor: 2.104

9.  The use of computed tomography in pediatrics and the associated radiation exposure and estimated cancer risk.

Authors:  Diana L Miglioretti; Eric Johnson; Andrew Williams; Robert T Greenlee; Sheila Weinmann; Leif I Solberg; Heather Spencer Feigelson; Douglas Roblin; Michael J Flynn; Nicholas Vanneman; Rebecca Smith-Bindman
Journal:  JAMA Pediatr       Date:  2013-08-01       Impact factor: 16.193

10.  Assessment of Radiation doses to Paediatric Patients in Computed Tomography Procedures.

Authors:  Khalid Alzimami
Journal:  Pol J Radiol       Date:  2014-10-01
View more
  2 in total

1.  Diagnostic Accuracy of Non-Invasive Thermal Evaluation of Ventriculoperitoneal Shunt Flow in Shunt Malfunction: A Prospective, Multi-Site, Operator-Blinded Study.

Authors:  Joseph R Madsen; Tehnaz P Boyle; Mark I Neuman; Eun-Hyoung Park; Mandeep S Tamber; Robert W Hickey; Gregory G Heuer; Joseph J Zorc; Jeffrey R Leonard; Julie C Leonard; Robert Keating; James M Chamberlain; David M Frim; Paula Zakrzewski; Petra Klinge; Lisa H Merck; Joseph Piatt; Jonathan E Bennett; David I Sandberg; Frederick A Boop; Mustafa Q Hameed
Journal:  Neurosurgery       Date:  2020-10-15       Impact factor: 4.654

Review 2.  Characterizing and quantifying low-value diagnostic imaging internationally: a scoping review.

Authors:  Elin Kjelle; Eivind Richter Andersen; Arne Magnus Krokeide; Lesley J J Soril; Leti van Bodegom-Vos; Fiona M Clement; Bjørn Morten Hofmann
Journal:  BMC Med Imaging       Date:  2022-04-21       Impact factor: 2.795

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.