Literature DB >> 30607077

Effect of Conventional and Microwave Tissue Processing Technique on DNA Integrity: A Comparative Molecular Analysis.

Dhara Dwivedi1, Sowmya Kasetty2, Manisha S Tijare3, Shreenivas Kallianpur4, Nitin Prabhakar5, Raju T Ragavendra2, Ami Desai6.   

Abstract

BACKGROUND: Methods of diagnostic molecular biology are routinely applied on formalin-fixed, paraffin-embedded tissues processed via conventional method. Recently, there has been a growing interest to use microwave technology in histopathology laboratories to overcome the deficiencies of the conventional processing method. Thefore, this study was aimed to compare and analyze the quality and quantity of DNA obtained from tissues processed by conventional and microwave tissue processing techniques and to further ascertain the applicability of the latter for PCR (polymerase chain reaction based research).
METHODS: Thirty fresh tissues of oral squamous cell carcinoma (OSCC) were included, and each sample was cut into two equivalent halves. One tissue half was processed by conventional manual method whereas the other half was processed using a domestic microwave oven. DNA was obtained from all the tissues which were then subjected to Polymerase chain reaction (PCR) to evaluate GAPDH (Glyceraldehyde-3-phosphate dehydrogenase) gene expression.
RESULTS: The results revealed better DNA yield from microwave processed tissue while the quality of the DNA was alike from both the techniques.
CONCLUSION: On the basis of the results obtained, it can be concluded that DNA produced by microwave processed tissues was similar to that obtained by conventional processing technique in terms of quantity and quality. Thus, microwave processed tissue samples can be successfully used for further molecular studies and researches.

Entities:  

Keywords:  GAPDH gene; Microwave tissue processing; molecular pathology; oral squamous cell carcinoma; polymerase chain reaction

Mesh:

Substances:

Year:  2018        PMID: 30607077      PMCID: PMC6308768          DOI: 10.4314/ejhs.v28i5.13

Source DB:  PubMed          Journal:  Ethiop J Health Sci        ISSN: 1029-1857


Introduction

The new-fangled accomplishments in the field of cancer diagnosis have seen a plethora of rapid and accurate high throughput diagnostic tests; these molecular diagnostic tests have now been demonstrated to be highly beneficial in the clinical scenario. Recently, there has been a growing interest in using polymerase chain reaction (PCR) to investigate the molecular changes in stepwise progression of various diseases including cancer (1). Lately, DNA extracted from formalin-fixed and paraffin-embedded tissues (FFPE) processed via conventional method has been successfully used for gene analysis by PCR (2). Routine manual tissue processing (conventional method) method is a reliable and an inexpensive procedure. However, it has many drawbacks including the exposure to noxious chemicals like xylene & formalin and longer time duration (3). In order to overcome the deficiencies of the conventional method, certain new methods were introduced like automatic tissue processing and microwave method. Of these, microwave tissue processing requires shorter processing time with minimum exposure to noxious chemicals (4). In this process, the penetrative properties of the microwave radiation and the conversion of this incident energy into heat is used; it was first used by Boon and Kok in 1985 (3). Since this technology was first adopted in pathology laboratories, many studies have been conducted and have already established the creditability of this technique for efficient tissue fixation and processing. However, no study has been conducted to compare the quality and quantity of the DNA obtained from the oral squamous cell carcinoma tissues, processed by conventional manual processing technique and microwave processing method and to further evaluate the viability of the procured DNA to be utilized for further molecular investigations. Thus, this study was intended to assess the PCR results of GAPDH gene expression in the extracted DNA samples and thereby to compare and analyze the effects of the microwave histoprocessing on DNA integrity and its applicability when compared with routine tissue processing techniques.

Methods

Formalin fixed OSCC tissue specimen formalin stored for less than 6 months were collected from the archives of People's College of Dental Sciences & Research Centre, Bhopal and Jawaharlal Nehru Cancer Hospital, Bhopal (India). Approval was obtained from the ethical committee of the involved institutes. Subsequent DNA analysis was performed in the Centre for Scientific Research and Development People's Group, Bhopal (India). Each sample was cut into two equal halves with each tissue bit measuring approximately 1.0 × 1.0 × 0.5 cm and fixed in 10% formalin for 24 hours. The samples were then grouped as following:

Tissue processing

Group A: The specimens were processed using the conventional method i.e. dehydrated in increasing concentrations of alcohol, cleared in xylene, impregnated in paraffin wax using hot air oven (Table1).
Table 1

Protocol for conventional tissue processing

StepsReagentsDuration (Minutes)
Dehydration70% Isopropyl alcohol60
80% Isopropyl alcohol60
90% Isopropyl alcohol60
100% Isopropyl alcohol60
100/% Isopropyl alcohol60
ClearingXylene60
Xylene60
ImpregnationParaffin waxOvernight
Total duration : 24 hours
Protocol for conventional tissue processing Group B: The tissue samples were washed under running tap water to remove formalin. They were then placed in a plastic cassette and transferred to microwave oven safe glass containers with the capacity of 500ml containing 200ml of the absolute isopropyl alcohol. A water load of 200 ml was placed in another microwave resistant beaker of capacity of 500ml. The two beakers were placed together in microwave oven which was operated at 40% power for two 20 minutes cycle. For impregnation procedure, the tissue was shifted to a beaker containing 200ml paraffin wax. This beaker along with the 200ml water load in another beaker was placed in microwave oven and run at 40% power for two cycles of 20 minutes. Minimal gap was kept between the two steps to avoid tissue desiccation. The procedure that was followed is given in Table 2.
Table 2

Protocol for microwave tissue processing

StepsReagent UsedDuration (Minutes)
DehydrationAbsolute isopropyl alcohol20
Absolute isopropyl alcohol20
ImpregnationParaffin wax20
Paraffin wax20
Total duration : 1hr 10 mins
Protocol for microwave tissue processing Tissues obtained after processing by both techniques were then embedded in paraffin wax using L molds. Hematoxylin and Eosin (H&E) stained sections were prepared; only those samples with diagnosis of squamous cell carcinoma were taken for the study. Sample preparation for PCR: About 25 µm thick sections were collected from paraffin embedded tissue blocks; 30 tissues in a given sample were kept constant. Sections were then transferred into 1.5 ml micro-centrifuge tube for DNA extraction procedure. DNA extraction: Xylene method was employed for the deparaffinization of paraffin-embedded tissues followed by the treatment with series of chilled graded ethanol washes (100%, 80% and 70%) centrifuged at 12,000 rpm for 10 minutes in micro centrifuge machine (Micro Centrifuge EPPENDORF-5804 R) to obtain tissue pellets. For protein digestion, 40 µl Proteinase K was employed. After proteinase K inactivation, DNA isolation was performed employing Phenol: Chloroform (Conventional) method. Later, DNA purification was carried out with alcohol. The yield of DNA was measured using a Picodrop UV-Spectrophotometer (PICOPET01 manufactured by Picodrop Ltd - Cambridge, U.K.) at 260nm with TE buffer; 1 µl of eluted DNA was taken in the pipette and the absorbance of various samples was obtained. PCR was performed using two different primer sets for the GAPDH gene, amplifying (96 base pairs) products; PCR fragments were amplified using the same forward primer (5′-CCCCACACACATGCACTTACC-3′) and reverse primers (5′ CCTAGTCCCAGGGCTTTGATT-3′) procured from Integrated DNA Technologies (IDT, USA). The amplification was programmed in an eppendorf master cycler gradient as detailed in Table 3.
Table 3

PCR programme for GAPDH primer

Step no.EventsTemperatureDuration
1Initial Denaturation95°C5 mins
2AmplificationDenaturation95°C1min45 Cycles
Annealing60°C1min
Extension72°C1 min
3Final extension72°C10 mins
PCR programme for GAPDH primer Electrophoresis and Analysis of PCR Product: The PCR products were loaded carefully into well of the casted gel, with controls (distilled water instead of template DNA) to test the purity and viability of reagents. Gel Electrophoresis Unit (AXYGEN, USA) was employed for the same. The analysis was performed for all the samples at least three times with each selected primers to check the reproducibility. A DNA ladder was also loaded along with the samples to quantify DNA, and electrophoresis was carried out at a constant voltage of 70V till the dye ran 3/4th distance on the gel. After the gel was ran it was placed on gel documentation system and was visualized by 302 nm high intensity UV light. Image was captured and analyzed by using Quantity One Software (Figures 1, 2). Molecular weight was calculated by using this software.
Figure 1

An agarose gel chromatograph showing GAPDH gene profile of the 30 DNA samples obtained from conventionally processed tissue under group A of the study; M,100bp DNA ladder

Figure 2

An agarose gel chromatograph showing GAPDH gene profile of the 30 DNA samples obtained from microwave processed tissue under group B of the study; M,100bp DNA ladder

An agarose gel chromatograph showing GAPDH gene profile of the 30 DNA samples obtained from conventionally processed tissue under group A of the study; M,100bp DNA ladder An agarose gel chromatograph showing GAPDH gene profile of the 30 DNA samples obtained from microwave processed tissue under group B of the study; M,100bp DNA ladder

Results

Statistical analysis was carried out to establish correlation between the two study groups for qualitative and quantitative assessment of the obtained DNA. Statistical difference was assessed by means of paired and unpaired t-test and Pearson chi-square tests using SPSS software. Purity of extracted DNA: The purity of the obtained DNA was estimated by calculating the ratio of absorbance at 260 nm and 280 nm measured using PicoDrop UV-Spectrophotometer. The ratio between 1.6 and 1.8 indicates the presence of nucleic acids. A ratio of less than 1.6 indicates additional presence of protein content and greater than 1.8 indicates RNA content or chloroform and phenol contamination. Samples with uncontaminated DNA (purity of 1.6–1.8) were more in group B; although Chi-Square test analysis demonstrated insignificant difference between the two groups. Difference between the two groups was calculated by applying unpaired t-test, and the P-value was found to be insignificant (Table 4).
Table 4

Samples with the possible contamination in both groups (Chi-Square Test Analysis)

GroupsSample size (n)No Contamination n (%)Protein Contamination n (%)RNA Contamination n (%)Chi – Square valueP-value
Group A3012 (40%)18 (60%)00.6060.436
Group B3015 (50%)15 (50%)0

n: Number of Samples, NS: Non Significant, P Values <0.05 and <0.01 are statistically significant and P value <0.001 is highly significant

Samples with the possible contamination in both groups (Chi-Square Test Analysis) n: Number of Samples, NS: Non Significant, P Values <0.05 and <0.01 are statistically significant and P value <0.001 is highly significant Quantity of extracted DNA: The mean quantities of the DNA extracted from the group B samples produced much higher mean DNA yield than group A. The outcome of unpaired t-test analysis revealed a significant relationship in the discrepancy between the two groups. Also, Chi-Square test was performed for the pairwise comparison of DNA quantity of the individual sample of the two groups which interprets that the numbers of the sample with the better DNA outturn were more in group B than in group; the p value = 0.002 was significant. In this study, the minimum tissue weight from which the DNA could be efficiently extracted was as little as 6mg and 2mg of the conventionally and microwave processed tissue respectively. Quality of extracted DNA - PCR amplifications in different groups: Quality of the DNA was assessed by observing its potential to be amplified. Although tissue samples of both the groups were successfully amplified, group B tissues revealed more number of amplification compared to group A. Furthermore, the minimum quantities of the DNA which could be successfully amplified were 7.91 ηg/µl & 10.85 ηg/µl of the conventional and microwave processed specimens.

Discussion

Oral squamous cell carcinoma (OSCC) is the eighth most common cancer worldwide associated with significant morbidity and mortality (5). Currently, oral carcinogenesis is hypothesized to be governed by the accretion of the genetic mutations affecting the structure and function of the genome at molecular level along with equally important epigenetic changes (6,7). Thus, genetic and genome based approaches have established themselves as the linchpin in the diagnosis and prognosis of oral cancer (8). Central to molecular diagnostics and assays are the nucleic acids (9). Amplification of nucleic acid sequences has brought new insights into the etiology of cancer that has proved to be highly useful for early detection, diagnosis and treatment (10,11); PCR being the method for the in vitro amplification of specific nucleic acid sequences has now become the mainstay of the use of molecular science in diagnosis and research (12). PCR provides with fine sensitivity that enables the molecular study of fixed paraffin-embedded tissue (PET) specimens, which comprise most archival clinical material. The extraction of nucleic acids from routinely fixed and processed tissue is particularly important as it permits the use of archival material for the retrospective investigation of disease (13). In spite of the tremendous advances made in the field of histoprocessing techniques, the majority of the laboratories continue to practice a century old technique for preserving and processing tissue specimen i.e. Formaldehyde fixation followed by conventional processing method. The conventional manual tissue processing technique requires a minimum of 8–16 hours, thereby causing a 1-day minimum delay in drawing the diagnosis (14). Furthermore, the use of toxic chemical reagents like xylene is the other important shortcoming associated with this technique. Exposure to xylene can occur via inhalation, ingestion, eye or skin contact with the probable damage to multiple body systems making it a potential occupational hazard for the histopathological technicians (15). Microwave tissue processing technique has surfaced as an antidote to all these obstacles. Although microwaves were invented by Percy Spencer in 1945; it was Mayers who pioneered the use of microwave technology in histologic procedures in 1970s (16,17). Understanding the technology and its various applications is the two most essential components which determine its overall success or failure. Microwaves are nonionizing radiations with electromagnetic properties with the frequencies ranging from 300 MHz to 300 GHz and wavelengths from 1 mm to 1 m (18). As the microwaves penetrate into the tissues, the energy is absorbed by the water molecules. In the oscillating electric fields produced by microwaves irradiation, the dipolar molecules like water are forced to vibrate. Some of the acquired rotational energy is transferred to the random motion upon collision with other molecules. This induced kinetic movement produces instantaneous heat which further increases the diffusion of the reagents and thereby decreases the tissue processing time. Unlike conventional heating, heating in microwave is from within (internal heating), and its effect occurs throughout the material being irradiated (19).

Microwave aided tissue processing

Temperature: The physicochemical basis of tissue processing lies in the diffusion of reagents into the substance of the tissue to be processed. This higher temperature facilitates diffusion, thereby allowing quicker tissue processing. Although the risk of tissue damage is there due to higher temperature, short exposure time does not allow that to happen. In this study, all the three steps of processing were carried out in 2 changes of 200ml of reagents for 20 minutes. Therfore, in order to prevent any kind of tissue damage, a water load of 200ml was also kept during every procedure. The commercially available microwave ovens are designed to provide precise control of specimen temperature which domestic ovens cannot. Kok et al recommend 67°C to be suitable for dehydration temperature while the following procedures were carried out between the range of 60°C to 82°C (20). Babu TM et al and Kango and Deshmukh used a domestic microwave oven in which the maximum temperature reached was 87°C and 58°C respectively. Stepwise assessment of the tissue temperature could not be recorded in this study, but the highest temperature attained was 84°C (16,21). Reagents: Depending upon their ability to absorb the microwave energy, some materials can be more microwavable than others. In this study, both dehydration and clearing were performed using iso propyl alcohol as it presents with various advantages over the others. These include: better ability to absorb the microwave energy i.e. more microwavable; safer than the toxic chemicals like xylene; boiling temperature of 82°C allows it to boil out readily in paraffin impregnation procedure; its dehydrating property; and Miscible in water. Besides, iso propyl alcohol, use of the other reagents such as graded alcohol and chloroform has also been suggested by some authors. However, in this study, iso propyl proved to be an effective dehydrant and clearing agent. Size of the specimen: The basic effect of microwave irradiation is stimulation of diffusion and enhancement of reaction rates with internal heating being the key element in the process. The formula which governs the rate of diffusion is = 2Dt, where x stands for net distance covered by a particle in solution in a certain direction; it is the time period during which diffusion occurs; D is the diffusion constant for the substance and < > stands for the average value. This implies that the average squared distance covered by a particle in solution is proportional to the diffusion time (22). This shows the need to keep the thickness of the biopsies small: three times as thick means nine times as long for comparable effects. Kok et al reiterated the importance of the thickness of the tissue to be irradiated and mentioned that it was the thickness and not the length or width of the tissue that mattered. They also mentioned that microwaves can penetrate upto a maximum depth of 2 cm, as the larger specimens would require additional cycles (16). Therefore, all the specimens selected for this study were less than 1x1x 0.5 cm in thickness (less than 2cm). In this study, DNA purity was the first parameter studied and compared. It was found that 50% of the microwave processed tissues contained pure DNA compared to only 40% of conventionally processed tissues showing uncontaminated DNA. These results are in accordance with findings of Bodor et al who were able to obtain the genomic DNA with a purity of 1.6–1.7 OD260/OD280 from both of the processing techniques evaluated in this study (23). Also, Hsu et al were able to retrieve excellent quality DNA from in situ hybridization when microwave fixed tissue were used, further supporting the outcome of this study (24). However, Aydin I et al found differing results; the DNA they obtained from formaldehyde fixed microwaved processed tissue was fragmented and not of good quality (25). The quantity of DNA is as important as its quality for subsequent molecular analysis; the second factor which was evaluated. After the interpretation of the data obtained, it was evident that the tissues processed utilizing the microwave method were able to produce much higher DNA than the routinely processed tissue by the conventional method. Banarjee SK et al and Aydin et al who had described a microwave based DNA extraction procedure from FFPE tissues arrived at a similar conclusion i.e. the derived DNA was of sufficient quantity (25,26). This parameter was also studied by Bodor et al who were successfully able to extract good quality and quantity of DNA after having the tissue processed by microwave apparatus (23). Apart from these, literature accommodates a few more researches which have highlighted the utility of the microwave for fruitful extraction of DNA. Lou et al reported that microwave treatment of the sample (cervivaginal lavage in this case) lead to adequate production of HPV DNA for its detection by PCR. They concluded that the higher denaturation temperature required for more efficient DNA extraction was better provided by microwave than by the conventional method in a short span of time and without much damage to the tissues; thus, emphasizing its utility for the same (27). Lastly, the quality of the extracted DNA was estimated as a measure of number of samples with amplifiable DNA. On the basis of the results of the GAPDH gene expression post PCR, it can be stated that DNA retrieved from microwave method can be as effectively amplified as those processed by the conventional overnight technique; hence, equally good quality from both the technique. Likewise, conclusions were drawn by Banarjee et al and Bodor et al who carried out positive amplification of ki-ras and β-globin gene in human tissues via PCR (23, 26). These results were further in congruence with the findings of Aydin et al, who reported successful PCR amplification of the DNA from microwave processed tissues (25). The practice of microwave assisted tissue processing has brought about a reassessment of traditional concepts by simplifying the paradigm of prolonged durations of conventional histoprocessing methods and curtailing it to several minutes. As evidenced by the results of this study, we were able consolidate microwave technology with the molecular biology techniques to prepare the formalin fixed tissues for the procurement of DNA with well preserved integrity and its further use for molecular procedures. Apart from its use in tissue processing, it has also been found to be profoundly effectual in tissue fixation, tissue section staining, antigen preservation and electron microscopy. Studies have established that the quality of microwave-processed and microwave-stained slides is identical or slightly better than conventionally processed and stained slides (18,21,22,28,29,30). Also, microwave technology has immensely contributed in the successful antigen retrieval as well as enhanced immunostaining in immunohistochemical procedures (18,30,31,32), it has been a significant addition to the DNA extraction methods too (34,35,36). Ten percent formaldehyde was used in this study as the tissue fixative is known to cause degradation of the nucleic acids. In pursuance of overcoming this impediment, further studies incorporating less harmful alternative fixatives along with microwave histoprocessing technique is recommended.
  29 in total

1.  Comparison of the DNA extraction methods for polymerase chain reaction amplification from formalin-fixed and paraffin-embedded tissues.

Authors:  Y Sato; R Sugie; B Tsuchiya; T Kameya; M Natori; K Mukai
Journal:  Diagn Mol Pathol       Date:  2001-12

Review 2.  Effect of fixatives and tissue processing on the content and integrity of nucleic acids.

Authors:  Mythily Srinivasan; Daniel Sedmak; Scott Jewell
Journal:  Am J Pathol       Date:  2002-12       Impact factor: 4.307

3.  Microwaves and turnaround times in histoprocessing: is this a new era in histotechnology?

Authors:  Anthony S Y Leong
Journal:  Am J Clin Pathol       Date:  2004-04       Impact factor: 2.493

4.  A comparison of immunohistochemical stain quality in conventional and rapid microwave processed tissues.

Authors:  Lyska L Emerson; Sheryl R Tripp; Bradley C Baird; Lester J Layfield; L Ralph Rohr
Journal:  Am J Clin Pathol       Date:  2006-02       Impact factor: 2.493

5.  Microwave processing and ethanol-based fixation in forensic pathology.

Authors:  Antonio Iesurum; Tiziana Balbi; Domenico Vasapollo; Alberto Cicognani; Claudio Ghimenton
Journal:  Am J Forensic Med Pathol       Date:  2006-06       Impact factor: 0.921

6.  Antigen retrieval in formalin-fixed, paraffin-embedded tissues: an enhancement method for immunohistochemical staining based on microwave oven heating of tissue sections.

Authors:  S R Shi; M E Key; K L Kalra
Journal:  J Histochem Cytochem       Date:  1991-06       Impact factor: 2.479

7.  DNA and RNA isolated from tissues processed by microwave-accelerated apparatus MFX-800-3 are suitable for subsequent PCR and Q-RT-PCR amplification.

Authors:  Csaba Bödör; Otto Schmidt; Balázs Csernus; Hajnalka Rajnai; Béla Szende
Journal:  Pathol Oncol Res       Date:  2007-07-03       Impact factor: 3.201

8.  Microwave histoprocessing versus conventional histoprocessing.

Authors:  Alka Mary Mathai; Ramadas Naik; Muktha R Pai; Sharada Rai; Poornima Baliga
Journal:  Indian J Pathol Microbiol       Date:  2008 Jan-Mar       Impact factor: 0.740

Review 9.  Genetic and epigenetic alterations as biomarkers for cancer detection, diagnosis and prognosis.

Authors:  Zdenko Herceg; Pierre Hainaut
Journal:  Mol Oncol       Date:  2007-03-14       Impact factor: 6.603

10.  High quality of DNA retrieved for Southern blot hybridization from microwave-fixed, paraffin-embedded liver tissues.

Authors:  H C Hsu; S Y Peng; C T Shun
Journal:  J Virol Methods       Date:  1991 Feb-Mar       Impact factor: 2.014

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.