Literature DB >> 30603368

Effect of switching from conventional continuous subcutaneous insulin infusion to sensor augmented pump therapy on glycemic profile in Japanese patients with type 1 diabetes.

Atsuko Matsuoka1, Yushi Hirota1, Shin Urai1, Tetsushi Hamaguchi1, Takehito Takeuchi1, Hiroshi Miura1, Natsu Suematsu1, Anna So1, Tomoaki Nakamura1, Hisako Komada1, Yuko Okada1, Kazuhiko Sakaguchi2, Wataru Ogawa1.   

Abstract

AIMS: Evidence suggests that sensor augmented pump (SAP) therapy is superior to conventional continuous subcutaneous insulin infusion (CSII) for achieving glycemic control in patients with type 1 diabetes. However, the clinical benefit of SAP therapy in East Asians has not yet been demonstrated.
METHODS: The effect of switching from conventional CSII to SAP therapy on glycemic profile was examined in 18 Japanese patients with type 1 diabetes. The glycemic profile of the patients was determined by retrospective continuous glucose monitoring (CGM) within 1 month before the treatment switch, whereas that at 6 and 12 months after the switch was evaluated with the CGM function of the SAP device. Hemoglobin A1c levels were also measured before and after the switch to SAP therapy.
RESULTS: The duration of hypoglycemia was significantly decreased at both 6 and 12 months after the change in treatment (6.6 ± 4.5, 3.2 ± 4.1, and 3.0 ± 2.8 min/h for before and 6 and 12 months, respectively), as was the HbA1c level at 12 months (7.8 ± 1.0 and 7.4 ± 0.9%, respectively). The duration of hyperglycemia did not differ between before and after the treatment switch. The decline in HbA1c level at 12 months after the switch to SAP was negatively correlated with age.
CONCLUSION: Switching from conventional CSII to SAP therapy was associated with a decrease in both the duration of hypoglycemia and the level of HbA1c in Japanese patients with type 1 diabetes.

Entities:  

Keywords:  Continuous subcutaneous insulin infusion; Hypoglycemia; Sensor augmented pump; Type 1 diabetes

Year:  2018        PMID: 30603368      PMCID: PMC6224909          DOI: 10.1007/s13340-018-0344-4

Source DB:  PubMed          Journal:  Diabetol Int        ISSN: 2190-1678


  24 in total

1.  Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes.

Authors:  David M Nathan; Patricia A Cleary; Jye-Yu C Backlund; Saul M Genuth; John M Lachin; Trevor J Orchard; Philip Raskin; Bernard Zinman
Journal:  N Engl J Med       Date:  2005-12-22       Impact factor: 91.245

2.  Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor: a randomized controlled trial.

Authors:  Satish Garg; Howard Zisser; Sherwyn Schwartz; Timothy Bailey; Roy Kaplan; Samuel Ellis; Lois Jovanovic
Journal:  Diabetes Care       Date:  2006-01       Impact factor: 19.112

3.  Is the frequency of self-monitoring of blood glucose related to long-term metabolic control? Multicenter analysis including 24,500 patients from 191 centers in Germany and Austria.

Authors:  M Schütt; W Kern; U Krause; P Busch; A Dapp; R Grziwotz; I Mayer; J Rosenbauer; C Wagner; A Zimmermann; W Kerner; R W Holl
Journal:  Exp Clin Endocrinol Diabetes       Date:  2006-07       Impact factor: 2.949

4.  Self-monitoring of blood glucose: language and financial barriers in a managed care population with diabetes.

Authors:  A J Karter; A Ferrara; J A Darbinian; L M Ackerson; J V Selby
Journal:  Diabetes Care       Date:  2000-04       Impact factor: 19.112

5.  Frequency and motives of blood glucose self-monitoring in type 1 diabetes.

Authors:  M V Hansen; U Pedersen-Bjergaard; S R Heller; T M Wallace; A K Rasmussen; H V Jørgensen; S Pramming; B Thorsteinsson
Journal:  Diabetes Res Clin Pract       Date:  2009-06-03       Impact factor: 5.602

6.  Glycaemic impact of patient-led use of sensor-guided pump therapy in type 1 diabetes: a randomised controlled trial.

Authors:  M A O'Connell; S Donath; D N O'Neal; P G Colman; G R Ambler; T W Jones; E A Davis; F J Cameron
Journal:  Diabetologia       Date:  2009-04-25       Impact factor: 10.122

7.  Modern-day clinical course of type 1 diabetes mellitus after 30 years' duration: the diabetes control and complications trial/epidemiology of diabetes interventions and complications and Pittsburgh epidemiology of diabetes complications experience (1983-2005).

Authors:  David M Nathan; Bernard Zinman; Patricia A Cleary; Jye-Yu C Backlund; Saul Genuth; Rachel Miller; Trevor J Orchard
Journal:  Arch Intern Med       Date:  2009-07-27

Review 8.  Hypoglycemia in diabetes.

Authors:  Philip E Cryer; Stephen N Davis; Harry Shamoon
Journal:  Diabetes Care       Date:  2003-06       Impact factor: 19.112

Review 9.  Severe hypoglycaemia and glycaemic control in Type 1 diabetes: meta-analysis of multiple daily insulin injections compared with continuous subcutaneous insulin infusion.

Authors:  J C Pickup; A J Sutton
Journal:  Diabet Med       Date:  2008-07       Impact factor: 4.359

10.  The effect of continuous glucose monitoring in well-controlled type 1 diabetes.

Authors:  Roy W Beck; Irl B Hirsch; Lori Laffel; William V Tamborlane; Bruce W Bode; Bruce Buckingham; Peter Chase; Robert Clemons; Rosanna Fiallo-Scharer; Larry A Fox; Lisa K Gilliam; Elbert S Huang; Craig Kollman; Aaron J Kowalski; Jean M Lawrence; Joyce Lee; Nelly Mauras; Michael O'Grady; Katrina J Ruedy; Michael Tansey; Eva Tsalikian; Stuart A Weinzimer; Darrell M Wilson; Howard Wolpert; Tim Wysocki; Dongyuan Xing
Journal:  Diabetes Care       Date:  2009-05-08       Impact factor: 19.112

View more
  4 in total

1.  A sensor augmented pump may improve awareness of hypoglycemia and quality of life in Japanese patients with type 1 diabetes mellitus.

Authors:  Satoshi Takagi; Junnosuke Miura; Kanako Shimura; Sari Hoshina; Yukiko Tsuchida; Mikako Takita; Shota Mochizuki; Zhuo Shen; Takuya Asanuma; Hiroko Takaike; Tetsuya Babazono
Journal:  Diabetol Int       Date:  2021-09-02

2.  The hypoglycemia-prevention effect of sensor-augmented pump therapy with predictive low glucose management in Japanese patients with type 1 diabetes mellitus: a short-term study.

Authors:  Akihiro Katayama; Atsuhito Tone; Mayu Watanabe; Sanae Teshigawara; Satoshi Miyamoto; Jun Eguchi; Atsuko Nakatsuka; Kenichi Shikata; Jun Wada
Journal:  Diabetol Int       Date:  2019-09-16

3.  Type 1 diabetes woman with repeated miscarriages successfully gave birth after introducing an insulin pump with a predictive low glucose suspend feature.

Authors:  Hisae Honoki; Kunimasa Yagi; Sayaka Tsuda; Tsutomu Wada; Asako Enkaku; Maki Nakagawa-Yokoyama; Miki Kamigishi; Masataka Shikata; Akiko Takikawa-Nishiday; Shiho Fujisaka; Daisuke Chujo; Toshiyasu Sasaoka; Akitoshi Nakashima; Shigeru Saito; Kazuyuki Tobe
Journal:  Diabetol Int       Date:  2021-03-06

Review 4.  Evolution of Insulin Delivery Devices: From Syringes, Pens, and Pumps to DIY Artificial Pancreas.

Authors:  Jothydev Kesavadev; Banshi Saboo; Meera B Krishna; Gopika Krishnan
Journal:  Diabetes Ther       Date:  2020-05-14       Impact factor: 2.945

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.