Literature DB >> 19497633

Frequency and motives of blood glucose self-monitoring in type 1 diabetes.

M V Hansen1, U Pedersen-Bjergaard, S R Heller, T M Wallace, A K Rasmussen, H V Jørgensen, S Pramming, B Thorsteinsson.   

Abstract

AIMS: Recommendations for self-monitoring of blood glucose (SMBG) from the DCCT have not been implemented with the same rigour as recommendations for intensifying insulin therapy. We assessed the frequency of and motives for SMBG and compared SMBG behaviour with clinical, behavioural and demographic characteristics.
METHODS: Cross-sectional Danish-British multicentre survey of 1076 consecutive patients with type 1 diabetes, who completed a detailed questionnaire on SMBG and related issues. The key variables were test frequency and motive.
RESULTS: SMBG was performed daily by 39% of the patients and less than weekly by 24%. Sixty-seven percent reported to perform routine testing, while the remaining 33% only tested when hypo- or hyperglycaemia was suspected. Age, gender, and level of diabetes-related concern were associated with test pattern. Reported frequencies of mild and severe hypoglycaemia and awareness of hypoglycaemia were independently associated with testing behaviour, whereas the presence of late diabetic complications was not. Lower HbA1c was associated with more frequent testing.
CONCLUSION: Patient compliance regarding SMBG is limited. Thus, almost two thirds of the patients do not perform daily SMBG and one third do not perform routine tests.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19497633     DOI: 10.1016/j.diabres.2009.04.022

Source DB:  PubMed          Journal:  Diabetes Res Clin Pract        ISSN: 0168-8227            Impact factor:   5.602


  21 in total

Review 1.  Physical activity and type 1 diabetes: time for a rewire?

Authors:  Sheri R Colberg; Remmert Laan; Eyal Dassau; David Kerr
Journal:  J Diabetes Sci Technol       Date:  2015-01-06

2.  Integrated self-monitoring of blood glucose system: handling step analysis.

Authors:  Guido Freckmann; Christina Schmid; Katharina Ruhland; Annette Baumstark; Cornelia Haug
Journal:  J Diabetes Sci Technol       Date:  2012-07-01

Review 3.  The use of engineered protein materials in electrochemical devices.

Authors:  Julie N Renner; Shelley D Minteer
Journal:  Exp Biol Med (Maywood)       Date:  2016-04-27

Review 4.  Blood glucose pattern management in diabetes: creating order from disorder.

Authors:  Pratik Choudhary; Stefano Genovese; Gérard Reach
Journal:  J Diabetes Sci Technol       Date:  2013-11-01

5.  Decisions in the Psychology of Glucose Monitoring.

Authors:  Gérard Reach
Journal:  J Diabetes Sci Technol       Date:  2019-06-14

6.  Design and Methods of a Randomized Trial of Continuous Glucose Monitoring in Persons With Type 1 Diabetes With Impaired Glycemic Control Treated With Multiple Daily Insulin Injections (GOLD Study).

Authors:  Marcus Lind; William Polonsky; Irl B Hirsch; Tim Heise; Jan Bolinder; Sofia Dahlqvist; Nils-Gunnar Pehrsson; Peter Moström
Journal:  J Diabetes Sci Technol       Date:  2016-05-03

7.  Remote Health Consultations Supported by a Diabetes Management Web Application With a New Glucose Meter Demonstrates Improved Glycemic Control.

Authors:  Mike Grady; Hilary Cameron; Brian L Levy; Laurence B Katz
Journal:  J Diabetes Sci Technol       Date:  2016-05-03

Review 8.  Noninvasive monitoring of glucose levels: is exhaled breath the answer?

Authors:  Kiera Roberts; Adam Jaffe; Charles Verge; Paul S Thomas
Journal:  J Diabetes Sci Technol       Date:  2012-05-01

9.  Evaluation of a New Noninvasive Glucose Monitoring Device by Means of Standardized Meal Experiments.

Authors:  Andreas Pfützner; Stephanie Strobl; Filiz Demircik; Lisa Redert; Johannes Pfützner; Anke H Pfützner; Alexander Lier
Journal:  J Diabetes Sci Technol       Date:  2018-02-16

Review 10.  Influences on Technology Use and Efficacy in Type 1 Diabetes.

Authors:  Victoria Franklin
Journal:  J Diabetes Sci Technol       Date:  2016-05-03
View more