The hypoglycemia-prevention effect of sensor-augmented pump therapy with predictive low glucose management in Japanese patients with type 1 diabetes mellitus: a short-term study.

Akihiro Katayama1, Atsuhito Tone2, Mayu Watanabe3, Sanae Teshigawara2, Satoshi Miyamoto4, Jun Eguchi5, Atsuko Nakatsuka5, Kenichi Shikata4, Jun Wada5.   

Abstract

AIMS/
INTRODUCTION: The predictive low glucose management (PLGM) system was introduced in March 2018 in Japan. Although there are some reports demonstrating the benefit of PLGM in preventing hypoglycemia, no data are currently available in Japanese patients with type 1 diabetes mellitus (T1DM). The aim of the present study is to evaluate the effect of PLGM with sensor-augmented pump therapy in the prevention of hypoglycemia in Japanese patients.
MATERIALS AND METHODS: We included 16 patients with T1DM who used the MiniMed®640G system after switching from the MiniMed®620G system. We retrospectively analysed the data of the continuous glucose monitoring system in 1 month after switching to MiniMed®640G.
RESULTS: The area under the curve (AUC) of hypoglycemia of < 70 mg/dL was lowered from 0.42 ± 0.43 mg/dL day to 0.18 ± 0.18 mg/dL day (P = 0.012). Correspondingly, the duration of severe hypoglycemia (< 54 mg/dL) was reduced significantly from 15.3 ± 21.7 min/day to 4.8 ± 6.9 min/day (P = 0.019). The duration of hypoglycemia was reduced, but the reduction was not significant. Regarding the AUC for hyperglycemia > 180 mg/dL and the duration of hyperglycemia did not change. With the PLGM function, 79.3% of the predicted hypoglycemic events were avoided.
CONCLUSIONS: The hypoglycemia avoidance rate was comparable to those in previous reports. In addition, we demonstrated that PLGM can markedly suppress severe hypoglycemia without deteriorating glycemic control in Japanese T1DM patients. It is necessary to further investigate the effective use of the PLGM feature such as establishing a lower limit and the timing of resumption. © The Japan Diabetes Society 2019.

Entities:  

Keywords:  Hypoglycemia; Predictive low glucose management (PLGM); Sensor-augmented pump therapy (SAP); Type 1 diabetes mellitus (T1DM)

Year:  2019        PMID: 32206479      PMCID: PMC7082487          DOI: 10.1007/s13340-019-00408-7

Source DB:  PubMed          Journal:  Diabetol Int        ISSN: 2190-1678


  19 in total

1.  Optimal predictive low glucose management settings during physical exercise in adolescents with type 1 diabetes.

Authors:  Valentino Cherubini; Rosaria Gesuita; Edlira Skrami; Ivana Rabbone; Riccardo Bonfanti; Claudia Arnaldi; Giuseppe D'Annunzio; Annapaola Frongia; Fortunato Lombardo; Elvira Piccinno; Riccardo Schiaffini; Sonia Toni; Stefano Tumini; Davide Tinti; Paola Cipriano; Nicola Minuto; Lorenzo Lenzi; Lucia Ferrito; Claudia Ventrici; Federica Ortolani; Ohad Cohen; Andrea Scaramuzza
Journal:  Pediatr Diabetes       Date:  2018-11-22       Impact factor: 4.866

2.  Outpatient safety assessment of an in-home predictive low-glucose suspend system with type 1 diabetes subjects at elevated risk of nocturnal hypoglycemia.

Authors:  Bruce A Buckingham; Fraser Cameron; Peter Calhoun; David M Maahs; Darrell M Wilson; H Peter Chase; B Wayne Bequette; John Lum; Judy Sibayan; Roy W Beck; Craig Kollman
Journal:  Diabetes Technol Ther       Date:  2013-07-24       Impact factor: 6.118

3.  Prevention of Hypoglycemia With Predictive Low Glucose Insulin Suspension in Children With Type 1 Diabetes: A Randomized Controlled Trial.

Authors:  Tadej Battelino; Revital Nimri; Klemen Dovc; Moshe Phillip; Natasa Bratina
Journal:  Diabetes Care       Date:  2017-03-28       Impact factor: 19.112

4.  Efficacy of an Overnight Predictive Low-Glucose Suspend System in Relation to Hypoglycemia Risk Factors in Youth and Adults With Type 1 Diabetes.

Authors:  Peter M Calhoun; Bruce A Buckingham; David M Maahs; Irene Hramiak; Darrell M Wilson; Tandy Aye; Paula Clinton; Peter Chase; Laurel Messer; Craig Kollman; Roy W Beck; John Lum
Journal:  J Diabetes Sci Technol       Date:  2016-11-01

5.  Quantifying the impact of a short-interval interruption of insulin-pump infusion sets on glycemic excursions.

Authors:  Howard Zisser
Journal:  Diabetes Care       Date:  2007-12-04       Impact factor: 19.112

6.  Threshold-based insulin-pump interruption for reduction of hypoglycemia.

Authors:  Richard M Bergenstal; David C Klonoff; Satish K Garg; Bruce W Bode; Melissa Meredith; Robert H Slover; Andrew J Ahmann; John B Welsh; Scott W Lee; Francine R Kaufman
Journal:  N Engl J Med       Date:  2013-06-22       Impact factor: 91.245

7.  Safety of nighttime 2-hour suspension of Basal insulin in pump-treated type 1 diabetes even in the absence of low glucose.

Authors:  Jennifer L Sherr; Miladys Palau Collazo; Eda Cengiz; Camille Michaud; Lori Carria; Amy T Steffen; Kate Weyman; Melinda Zgorski; Eileen Tichy; William V Tamborlane; Stuart A Weinzimer
Journal:  Diabetes Care       Date:  2013-10-29       Impact factor: 19.112

8.  "Let the Algorithm Do the Work": Reduction of Hypoglycemia Using Sensor-Augmented Pump Therapy with Predictive Insulin Suspension (SmartGuard) in Pediatric Type 1 Diabetes Patients.

Authors:  Torben Biester; Olga Kordonouri; Martin Holder; Kerstin Remus; Dorothee Kieninger-Baum; Tanja Wadien; Thomas Danne
Journal:  Diabetes Technol Ther       Date:  2017-01-18       Impact factor: 6.118

9.  A randomized trial of a home system to reduce nocturnal hypoglycemia in type 1 diabetes.

Authors:  David M Maahs; Peter Calhoun; Bruce A Buckingham; H Peter Chase; Irene Hramiak; John Lum; Fraser Cameron; B Wayne Bequette; Tandy Aye; Terri Paul; Robert Slover; R Paul Wadwa; Darrell M Wilson; Craig Kollman; Roy W Beck
Journal:  Diabetes Care       Date:  2014-05-07       Impact factor: 19.112

10.  Effectiveness of Automated Insulin Management Features of the MiniMed® 640G Sensor-Augmented Insulin Pump.

Authors:  Alex Zhong; Pratik Choudhary; Chantal McMahon; Pratik Agrawal; John B Welsh; Toni L Cordero; Francine R Kaufman
Journal:  Diabetes Technol Ther       Date:  2016-09-27       Impact factor: 6.118

View more
  4 in total

1.  Sudden Death Associated with Severe Hypoglycemia in a Diabetic Patient During Sensor-Augmented Pump Therapy with the Predictive Low Glucose Management System.

Authors:  Kota Nishihama; Kazuhito Eguchi; Kanako Maki; Yuko Okano; Soichiro Tanaka; Chisa Inoue; Akihiro Uchida; Mei Uemura; Toshinari Suzuki; Taro Yasuma; Corina N D'Alessandro-Gabazza; Esteban C Gabazza; Yutaka Yano
Journal:  Am J Case Rep       Date:  2021-01-19

2.  Sensor-Augmented Insulin Pump with Predictive Low-Glucose Suspend (PLGS): Determining Optimal Settings of Pump and Sensor in a Multicenter Cohort of Patients with Type 1 Diabetes.

Authors:  Michael Joubert; Anaïs R Briant; Laurence Kessler; Fatéma Fall-Mostaine; Severine Dubois; Bruno Guerci; Laurène Schoumacker-Ley; Yves Reznik; Jean-Jacques Parienti
Journal:  Diabetes Ther       Date:  2022-08-01       Impact factor: 3.595

3.  Long-term efficacy of sensor-augmented pump therapy (Minimed 640G system) combined with a telemedicine follow-up in patients with type 1 diabetes: A real life study.

Authors:  Léonie Makuété Notemi; Lamia Amoura; Fatéma Fall Mostaine; Laurent Meyer; Dominique Paris; Samy Talha; Julien Pottecher; Laurence Kessler
Journal:  J Clin Transl Endocrinol       Date:  2022-10-01

4.  Type 1 diabetes woman with repeated miscarriages successfully gave birth after introducing an insulin pump with a predictive low glucose suspend feature.

Authors:  Hisae Honoki; Kunimasa Yagi; Sayaka Tsuda; Tsutomu Wada; Asako Enkaku; Maki Nakagawa-Yokoyama; Miki Kamigishi; Masataka Shikata; Akiko Takikawa-Nishiday; Shiho Fujisaka; Daisuke Chujo; Toshiyasu Sasaoka; Akitoshi Nakashima; Shigeru Saito; Kazuyuki Tobe
Journal:  Diabetol Int       Date:  2021-03-06
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.