Yuan-Chen Wang1, Jun Pan1, Xi Jiang1, Xiao-Ju Su1, Wei Zhou1, Wen-Bin Zou1, Yang-Yang Qian1, Yi-Zhi Chen1, Xiao Liu1, Jin Yu1, Xiao-Nan Yan1, An-Jing Zhao1, Zhao-Shen Li1, Zhuan Liao2. 1. National Clinical Research Center for Digestive Diseases, Department of Gastroenterology, Changhai Hospital, Second Military Medical University, 168 Changhai Road, Shanghai, 200433, China. 2. National Clinical Research Center for Digestive Diseases, Department of Gastroenterology, Changhai Hospital, Second Military Medical University, 168 Changhai Road, Shanghai, 200433, China. liaozhuan@smmu.edu.cn.
Abstract
BACKGROUND AND AIMS: Good gastric preparation is essential for magnetically controlled capsule gastroscopy (MCCG) examination. This study aims to determine if repetitive position change after dimethicone premedication could further improve gastric cleanliness for MCCG. METHODS:Consecutive patients referred for MCCG in our center from May 7 to May 31, 2018 were prospectively enrolled and randomized to undergorepetitive position change for 15 min (position change group) or not (conventional group) after ingesting dimethicone. Primary outcome was gastric cleanliness score and secondary outcomes were detection rate of positive findings, number of lesions per patient, gastric examination time, and safety of MCCG. RESULTS:Totals of 43 and 40 were included in the position change and conventional groups, respectively. Gastric cleanliness score in the position change group was significantly higher than in the conventional group (21.2 ± 1.0 vs. 18.6 ± 2.0, P < 0.001), as was the proportion of acceptable gastric cleanliness (gastric cleanliness score ≥ 18) (100% vs. 72.5%, P < 0.001). There was no statistical difference in detection rate of positive findings between the two groups (27.9% vs. 27.5%, P = 0.97). In the position change group, the gastric examination time was significantly reduced (13.2 ± 4.0 vs. 15.3 ± 5.1, P = 0.043). No adverse events were observed. CONCLUSIONS: Repetitive position change after dimethicone premedication significantly improves gastric cleanliness for MCCG examination. Clinical Trial Registration ClinicalTrials.gov, ID: NCT03514966.
RCT Entities:
BACKGROUND AND AIMS: Good gastric preparation is essential for magnetically controlled capsule gastroscopy (MCCG) examination. This study aims to determine if repetitive position change after dimethicone premedication could further improve gastric cleanliness for MCCG. METHODS: Consecutive patients referred for MCCG in our center from May 7 to May 31, 2018 were prospectively enrolled and randomized to undergo repetitive position change for 15 min (position change group) or not (conventional group) after ingesting dimethicone. Primary outcome was gastric cleanliness score and secondary outcomes were detection rate of positive findings, number of lesions per patient, gastric examination time, and safety of MCCG. RESULTS: Totals of 43 and 40 were included in the position change and conventional groups, respectively. Gastric cleanliness score in the position change group was significantly higher than in the conventional group (21.2 ± 1.0 vs. 18.6 ± 2.0, P < 0.001), as was the proportion of acceptable gastric cleanliness (gastric cleanliness score ≥ 18) (100% vs. 72.5%, P < 0.001). There was no statistical difference in detection rate of positive findings between the two groups (27.9% vs. 27.5%, P = 0.97). In the position change group, the gastric examination time was significantly reduced (13.2 ± 4.0 vs. 15.3 ± 5.1, P = 0.043). No adverse events were observed. CONCLUSIONS: Repetitive position change after dimethicone premedication significantly improves gastric cleanliness for MCCG examination. Clinical Trial Registration ClinicalTrials.gov, ID: NCT03514966.
Entities:
Keywords:
Dimethicone; Gastric cleanliness; Magnetically controlled capsule gastroscopy; Position change
Authors: Patricio M Polanco; Michelle R Ju; Matthieu Chansard; M Mathew Augustine; Jennie Meier; Eric Mortensen; Herbert J Zeh; Adam C Yopp Journal: Ann Surg Oncol Date: 2022-05-22 Impact factor: 4.339