Literature DB >> 24325147

Efficacy of simethicone and N-acetylcysteine as premedication in improving visibility during upper endoscopy.

Wei-Kuo Chang1, Ming-Kung Yeh, Hsuang-Chun Hsu, Hsuan-Wei Chen, Ming-Kuan Hu.   

Abstract

BACKGROUND: Simethicone and N-acetylcysteine have been widely used in improving endoscopic visibility. However, the optimal dose, volume, and dosing time for the premedication regimen are still unclear. AIM: Our aim was to assess the efficacy of premedication in improving endoscopic visibility and determine the contributions of dose, volume, and premedication time.
METHODS: A total of 1849 patients were prospectively treated in three groups: group A: 100-mg simethicone suspension in 5 mL water; group B: 100-mg simethicone suspension in 100 mL water; and group C: 100-mg simethicone suspension in 100 mL water containing 200 mg N-acetylcysteine. Mucosa visibility was assessed at seven sites of upper gastrointestinal tract. The sum of scores was considered as total mucosal visibility score (TMVS).
RESULTS: The upper body of stomach had the worst visibility score for all groups. TMVS of groups B and C were significantly lower than those of group A. Group C had a significantly fewer patients requiring endoscopic flushing than groups A and B. The TMVS for groups B and C were significantly lower than for group A within 30 min of beginning premedication. Beyond 30 min of premedication, there was no significant difference in the TMVS among groups.
CONCLUSIONS: Premedication using 100 mg simethicone in 100 mL of water improves endoscopic visibility. Addition of N-acetylcysteine to simethicone in 100 mL of water reduces the need for endoscopic flushing. For patients unable to tolerate a large fluid volume, a 5-mL simethicone suspension administered more than 30 min prior to upper endoscopy is suggested.
© 2013 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.

Entities:  

Keywords:  endoscopy; esophagogastroduodenoscopy; simethicone

Mesh:

Substances:

Year:  2014        PMID: 24325147     DOI: 10.1111/jgh.12487

Source DB:  PubMed          Journal:  J Gastroenterol Hepatol        ISSN: 0815-9319            Impact factor:   4.029


  13 in total

1.  Repetitive Position Change Improves Gastric Cleanliness for Magnetically Controlled Capsule Gastroscopy.

Authors:  Yuan-Chen Wang; Jun Pan; Xi Jiang; Xiao-Ju Su; Wei Zhou; Wen-Bin Zou; Yang-Yang Qian; Yi-Zhi Chen; Xiao Liu; Jin Yu; Xiao-Nan Yan; An-Jing Zhao; Zhao-Shen Li; Zhuan Liao
Journal:  Dig Dis Sci       Date:  2018-12-17       Impact factor: 3.199

2.  Effect of pronase as mucolytic agent on imaging quality of magnifying endoscopy.

Authors:  Gwang Ha Kim; Yu Kyung Cho; Jae Myung Cha; Sun-Young Lee; Il-Kwun Chung
Journal:  World J Gastroenterol       Date:  2015-02-28       Impact factor: 5.742

3.  An in vitro and clinical dose-finding study of antifoaming effects of simethicone during colonoscopy.

Authors:  Marguerite J Kutyla; Ayesha Shah; Jerome Elson; Vera Meeusen; Sam O'Connor; Luke F Hourigan; Gerald J Holtmann
Journal:  Indian J Gastroenterol       Date:  2019-07-17

Review 4.  Quality indicators in esophagogastroduodenoscopy.

Authors:  Sang Yoon Kim; Jae Myung Park
Journal:  Clin Endosc       Date:  2022-05-16

5.  Effectiveness of systematic alphanumeric coded endoscopy for diagnosis of gastric intraepithelial neoplasia in a low socioeconomic population.

Authors:  Nancy Roxana Machaca Quea; Fabian Emura; Fernando Barreda Bolaños; Yuliana Salvador Arias; Fernando Antonio Arévalo Suárez; Alejandro Piscoya Rivera
Journal:  Endosc Int Open       Date:  2016-10

6.  Efficacy of small-volume simethicone given at least 30 min before gastroscopy.

Authors:  Mingjun Song; Andrew Boon Eu Kwek; Ngai Moh Law; Jeannie Peng Lan Ong; Jessica Yi-Lyn Tan; Prem Harichander Thurairajah; Daphne Shih Wen Ang; Tiing Leong Ang
Journal:  World J Gastrointest Pharmacol Ther       Date:  2016-11-06

7.  A randomized controlled trial of pre-procedure simethicone and N-acetylcysteine to improve mucosal visibility during gastroscopy - NICEVIS.

Authors:  Peter John Basford; James Brown; Lisa Gadeke; Carole Fogg; Ben Haysom-Newport; Reuben Ogollah; Rupam Bhattacharyya; Gaius Longcroft-Wheaton; Fergus Thursby-Pelham; James R Neale; Pradeep Bhandari
Journal:  Endosc Int Open       Date:  2016-10-28

8.  Standing-type magnetically guided capsule endoscopy versus gastroscopy for gastric examination: multicenter blinded comparative trial.

Authors:  Hua-Sheng Lai; Xin-Ke Wang; Jian-Qun Cai; Xin-Mei Zhao; Ze-Long Han; Jie Zhang; Zhen-Yu Chen; Zhi-Zhao Lin; Ping-Hong Zhou; Bing Hu; Ai-Min Li; Si-de Liu
Journal:  Dig Endosc       Date:  2019-10-10       Impact factor: 7.559

9.  The effect of using simethicone with or without N-acetylcysteine before gastroscopy: A meta-analysis and systemic review.

Authors:  Yuanfa Li; Fangjuan Du; Dou Fu
Journal:  Saudi J Gastroenterol       Date:  2019 Jul-Aug       Impact factor: 2.485

10.  Feasibility of Upper Gastrointestinal Examination in Home Care Setting with a Magnetically Assisted Capsule Endoscopy System: A Retrospective Study.

Authors:  Yang-Chao Lin; Ching-Lin Chen; Yi-Wei Kao; Chi-Yang Chang; Ming-Chih Chen; Chih-Kuang Liu
Journal:  Healthcare (Basel)       Date:  2021-05-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.