Literature DB >> 12194665

Clinical bond failure of pre-coated and operator-coated orthodontic brackets.

K Kula1, R Schreiner, J Brown, A Glaros.   

Abstract

OBJECTIVES: To test the hypothesis that there is no significant difference in clinical bracket failure between the 3M APC Mini Twin bracket system and the Transbond XT adhesive during orthodontic treatment.
DESIGN: A randomized, split mouth, prospective clinical trial. SETTING AND SAMPLE POPULATION: The Department of Orthodontics and Dentofacial Orthopedics at University of Missouri, Kansas City. Twenty-nine subjects who were treatment planned to receive comprehensive orthodontics using 0.018 slot appliances. EXPERIMENTAL VARIABLE: The adhesive pre-coated brackets (APC) system was randomly assigned to one side of the mouth and the Transbond XT was assigned to the opposite side. OUTCOME MEASURE: The absence of any of the brackets at the time of a regular or emergency orthodontic appointment.
RESULTS: There was no significant difference (P > 0.05) in bracket failure between the 3M APC Mini Twin bracket system and the Transbond XT adhesive at any time period (90, 180, or 365 days). The failure rate of brackets on premolars was higher than on incisors or canines.
CONCLUSION: APC Mini Twin bracket system and Transbond XT adhesive are equally effective in maintaining brackets clinically. Inexperienced operators had an overall 7.5% bond failure 12 months following bracket placement.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12194665     DOI: 10.1034/j.1600-0544.2002.02199.x

Source DB:  PubMed          Journal:  Orthod Craniofac Res        ISSN: 1601-6335            Impact factor:   1.826


  10 in total

1.  Clinical performance of precoated brackets and self-etch bonding technique: a prospective comparative study.

Authors:  Ezgi Atik; Hande Gorucu-Coskuner; Tulin Taner
Journal:  Clin Oral Investig       Date:  2018-11-30       Impact factor: 3.573

2.  Adhesive precoated bracket systems and operator coated bracket systems: Is there any difference? A systematic review and meta-analysis.

Authors:  Ahmed Mohamed Alakttash; Mohamed Fawzi; David Bearn
Journal:  Angle Orthod       Date:  2018-12-17       Impact factor: 2.079

3.  A comparative assessment of bracket survival and adhesive removal time using flash-free or conventional adhesive for orthodontic bracket bonding: A split-mouth randomized controlled clinical trial.

Authors:  Thorsten Grünheid; Brent E Larson
Journal:  Angle Orthod       Date:  2018-09-19       Impact factor: 2.079

4.  Failure patterns of different bracket systems and their influence on treatment duration: A retrospective cohort study.

Authors:  Dimitrios Stasinopoulos; Spyridon N Papageorgiou; Frank Kirsch; Nikolaos Daratsianos; Andreas Jäger; Christoph Bourauel
Journal:  Angle Orthod       Date:  2018-02-02       Impact factor: 2.079

5.  Clinical effect of reducing curing times with high-intensity LED lights.

Authors:  Justin D Ward; Bethany J Wolf; Luis P Leite; Jing Zhou
Journal:  Angle Orthod       Date:  2015-03-11       Impact factor: 2.079

6.  Evaluation of Bond Failure Rate of Orthodontic Brackets Bonded with Green Gloo-Two Way Color Changes Adhesive: A Clinical Study.

Authors:  Zuber Ahamed Naqvi; Saleem Shaikh; Zameer Pasha
Journal:  Ethiop J Health Sci       Date:  2019-03

7.  Clinical bond failure rates of adhesive precoated self-ligating brackets using a self-etching primer.

Authors:  Mete Ozer; Mehmet Bayram; Cagri Dincyurek; Fuat Tokalak
Journal:  Angle Orthod       Date:  2013-07-02       Impact factor: 2.079

8.  Shear bond strength of precoated orthodontic brackets: an in vivo study.

Authors:  Ali H Hassan
Journal:  Clin Cosmet Investig Dent       Date:  2010-06-15

9.  Comparison of shear bond strength and adhesive remnant index between precoated and conventionally bonded orthodontic brackets.

Authors:  Ulises A Guzman; Laurance Jerrold; Peter S Vig; Ahmad Abdelkarim
Journal:  Prog Orthod       Date:  2013-10-20       Impact factor: 2.750

10.  Clinical performance of uncoated and precoated polymer mesh base ceramic brackets.

Authors:  Hüdanur Yılmaz Née Huda Abulkbash; Selma Elekdag-Türk
Journal:  Prog Orthod       Date:  2019-01-28       Impact factor: 2.750

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.