| Literature DB >> 30556048 |
Vaninder K Dhillon1, Lee M Akst1, Simon R Best1, Alexander T Hillel1.
Abstract
OBJECTIVES: Montgomery T-tubes enable patients with laryngotracheal stenosis to maintain airway patency. They also restore the ability to phonate in many patients. The primary objective is to compare voice quality of life outcomes in patients before and after Montgomery T-tube placement. The secondary objective is evaluating complications associated with T-tube placement.Entities:
Keywords: Endoscopic techniques; Laryngotracheal stenosis; Montgomery T-tube; Quality of life; Voice
Year: 2018 PMID: 30556048 PMCID: PMC6291003
Source DB: PubMed Journal: Clin Surg ISSN: 2474-1647
Demographic and baseline characteristics of the study subjects.
| N=13 | Overall | Etiology of laryngotracheal stenosis | |
|---|---|---|---|
| Age in years M | 45.8 (range: 26–68) | Iatrogenic (n=9) | Other (n=4) |
| Gender N (%) | |||
| Female | 10 (77%) | 7 (78%) | 3 (75%) |
| Male | 3 (23%) | 2 (22%) | 1 (25%) |
| History of tracheostomy N (%) | 13 (100%) | 9 (100%) | 4 (100%) |
| Cotton-Myer Classification | I–II | 1 (12%) | 0 (0%) |
| III–IV | 7 (88%) | 2 (100%) | |
| Obesity | 5 (100%) | 5 (100%) | 0 |
| History of open procedure | 5 (100%) | 5 (100%) | 0 |
| Duration of T-tube(average years) N | 2.44 | 1.19 | |
Iatrogenic: Intubation trauma and subsequent tracheostomy placement
Other: Recurrent respiratory papillomatosis, supracricoid laryngectomy with tracheal stenosis, primary tracheomalacia and penetrating trauma to the larynx
Obesity: BMI >30
Open procedure: tracheal resection, any open reconstruction of the trachea
Cotton-Myer Classification I–II: <70% stenosis; III–IV: 71% to 100% stenosis
Voice Related Quality of Life (VRQoL) measure pre and post T tube placement.
| Patient | Etiology of Laryngotracheal Stenosis | VRQoL pre T tube | VRQol post T tube | Aphonic Prior to T tube placement |
|---|---|---|---|---|
| 1 | Iatrogenic | 42.5 | 92.5 | No |
| 2 | Iatrogenic | 0 | 100 | Yes |
| 3 | Iatrogenic | 0 | 0 | No |
| 4 | Iatrogenic | 0 | 100 | Yes |
| 5 | Other | 70 | 72.5 | No |
| 6 | Other | 75 | 20 | No |
| 7 | Iatrogenic | 0 | 100 | Yes |
| 8 | Iatrogenic | 92.5 | 97.5 | Yes |
| 9 | Iatrogenic | 80 | 100 | No |
| 10 | Iatrogenic | 95 | 100 | No |
| 11 | Other | 60 | 65 | No |
| 12 | Iatrogenic | 30 | 90 | Yes |
| 13 | Other | 70 | 90 | No |
| Average VRQoL (N=13) | 43.5 | 79 | 5 (Total N) |
P<0.05
Complications after Montgomery T tube placement.
| Complications | N | Requiring tracheostomy replacement |
|---|---|---|
| Granulation tissue | 6 | |
| Difficulty ventilating (OSH) | 1 | 1 |
| Dyspnea/re-size T tube | 2 | 1 |
| Tracheitis | 2 | 1 |
| Migration of T tube | 1 | 1 |