Literature DB >> 30523998

Comparing Unet training with three different datasets to correct CBCT images for prostate radiotherapy dose calculations.

Guillaume Landry1, David Hansen, Florian Kamp, Minglun Li, Ben Hoyle, Jochen Weller, Katia Parodi, Claus Belka, Christopher Kurz.   

Abstract

Image intensity correction is crucial to enable cone beam computed tomography (CBCT) based radiotherapy dose calculations. This study evaluated three different deep learning based correction methods using a U-shaped convolutional neural network architecture (Unet) in terms of their photon and proton dose calculation accuracy. CT and CBCT imaging data of 42 prostate cancer patients were included. For target ground truth data generation, a CBCT correction method based on CT to CBCT deformable image registration (DIR) was used. The method yields a deformed CT called (i) virtual CT (vCT) which is used to generate (ii) corrected CBCT projections allowing the reconstruction of (iii) a final corrected CBCT image. The single Unet architecture was trained using these three different datasets: (Unet1) raw and corrected CBCT projections, (Unet2) raw CBCT and vCT image slices and (Unet3) raw and reference corrected CBCT image slices. Volumetric arc therapy (VMAT) and proton pencil beam scanning (PBS) single field uniform dose (SFUD) plans were optimized on the reference corrected image and recalculated on the obtained Unet-corrected CBCT images. The mean error (ME) and mean absolute error (MAE) for Unet1/2/3 were [Formula: see text] Hounsfield units (HU) and [Formula: see text] HU. The 1% dose difference pass rates were better than 98.4% for VMAT for 8 test patients not seen during training, with little difference between Unets. Gamma evaluation results were even better. For protons a gamma evaluation was employed to account for small range shifts, and [Formula: see text] mm pass rates for Unet1/2/3 were better than [Formula: see text] and 91%. A 3 mm range difference threshold was established. Only for Unet3 the 5th and 95th percentiles of the range difference distributions over all fields, test patients and dose profiles were within this threshold. A single Unet architecture was successfully trained using both CBCT projections and CBCT image slices. Since the results of the other Unets were poorer than Unet3, we conclude that training using corrected CBCT image slices as target data is optimal for PBS SFUD proton dose calculations, while for VMAT all Unets provided sufficient accuracy.

Entities:  

Year:  2019        PMID: 30523998     DOI: 10.1088/1361-6560/aaf496

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  17 in total

1.  Intelligent inverse treatment planning via deep reinforcement learning, a proof-of-principle study in high dose-rate brachytherapy for cervical cancer.

Authors:  Chenyang Shen; Yesenia Gonzalez; Peter Klages; Nan Qin; Hyunuk Jung; Liyuan Chen; Dan Nguyen; Steve B Jiang; Xun Jia
Journal:  Phys Med Biol       Date:  2019-05-29       Impact factor: 3.609

2.  Paired cycle-GAN-based image correction for quantitative cone-beam computed tomography.

Authors:  Joseph Harms; Yang Lei; Tonghe Wang; Rongxiao Zhang; Jun Zhou; Xiangyang Tang; Walter J Curran; Tian Liu; Xiaofeng Yang
Journal:  Med Phys       Date:  2019-07-17       Impact factor: 4.071

Review 3.  Online daily adaptive proton therapy.

Authors:  Francesca Albertini; Michael Matter; Lena Nenoff; Ye Zhang; Antony Lomax
Journal:  Br J Radiol       Date:  2019-11-11       Impact factor: 3.039

Review 4.  Adaptive proton therapy.

Authors:  Harald Paganetti; Pablo Botas; Gregory C Sharp; Brian Winey
Journal:  Phys Med Biol       Date:  2021-11-15       Impact factor: 3.609

5.  Convolutional neural network enhancement of fast-scan low-dose cone-beam CT images for head and neck radiotherapy.

Authors:  Nimu Yuan; Brandon Dyer; Shyam Rao; Quan Chen; Stanley Benedict; Lu Shang; Yan Kang; Jinyi Qi; Yi Rong
Journal:  Phys Med Biol       Date:  2020-01-27       Impact factor: 3.609

6.  Data-driven dose calculation algorithm based on deep U-Net.

Authors:  Jiawei Fan; Lei Xing; Peng Dong; Jiazhou Wang; Weigang Hu; Yong Yang
Journal:  Phys Med Biol       Date:  2020-12-22       Impact factor: 3.609

7.  Evaluation of CBCT scatter correction using deep convolutional neural networks for head and neck adaptive proton therapy.

Authors:  Arthur Lalonde; Brian Winey; Joost Verburg; Harald Paganetti; Gregory C Sharp
Journal:  Phys Med Biol       Date:  2020-12-04       Impact factor: 3.609

8.  Image-based shading correction for narrow-FOV truncated pelvic CBCT with deep convolutional neural networks and transfer learning.

Authors:  Matteo Rossi; Gabriele Belotti; Chiara Paganelli; Andrea Pella; Amelia Barcellini; Pietro Cerveri; Guido Baroni
Journal:  Med Phys       Date:  2021-10-26       Impact factor: 4.506

9.  Developments in deep learning based corrections of cone beam computed tomography to enable dose calculations for adaptive radiotherapy.

Authors:  Vicki Trier Taasti; Peter Klages; Katia Parodi; Ludvig Paul Muren
Journal:  Phys Imaging Radiat Oncol       Date:  2020-08-12

10.  Imaging science and development in modern high-precision radiotherapy.

Authors:  Daniela Thorwarth; Ludvig Muren
Journal:  Phys Imaging Radiat Oncol       Date:  2019-12-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.