Literature DB >> 30502638

The history of suture anchors in orthopaedic surgery.

Luke E Visscher1, Chris Jeffery2, Timothy Gilmour3, Libby Anderson4, Gregory Couzens5.   

Abstract

The suture anchor allows secure fixation of soft tissue to bone and has become an invaluable tool for the orthopaedic surgeon. The original suture anchor was developed over 3 decades ago when a suture was bonded to a headless screw. Since then anchors have undergone a wide variety of design modifications to increase strength and allow for new applications based on biomechanical and clinical evidence. The suture anchor chain consists of the anchor to bone fixation, anchor suture interface, suture itself and suture to soft tissue interface. The early suture anchors failed most commonly from anchor pull out or breakage, with the strongest early design being a bone-screw-suture complex. Early concerns of metalwork complications saw the introduction of biodegradable suture anchors, originally lactic acid polymers and then osteoconductive bio-composites. Improvements in anchor design saw the suture become the main link of failure until the advent of novel suture materials made of ultrahigh molecular weight polyethylene. A form failure of suture at the anchor eyelet via cut-out led to redesign of the anchor suture interface with novel eyelet designs. Further innovations in the anchor suture interface have seen the advent of knotless anchors, especially useful in arthroscopic surgery. The newest products are all-suture anchors which show impressive strength whilst reducing the iatrogenic damage caused by insertion. The further biomechanical development of suture anchors is likely to produce new designs that continue to increase strength whilst managing size requirements for tailored clinical applications.
Copyright © 2018 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Arthroscopy; Orthopaedics; Pull out; Surgery; Suture anchor

Mesh:

Year:  2018        PMID: 30502638     DOI: 10.1016/j.clinbiomech.2018.11.008

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  11 in total

1.  A Novel Technique of Proximal Humerus Fixation.

Authors:  M N Baig; Megan Diack; Ben Murphy; Kenneth Kaar
Journal:  Cureus       Date:  2020-04-17

2.  Clinical and Radiological Outcomes of Rotator Cuff Repairs Using All-Suture Anchors as Medial Row Anchors.

Authors:  Kashif A Memon; Richard Dimock; Alessio Bernasconi; Anshul Sobti; Paolo Consigliere; Mohamed A Imam; A Ali Narvani
Journal:  Arch Bone Jt Surg       Date:  2021-09

Review 3.  Biomaterials Used for Suture Anchors in Orthopedic Surgery.

Authors:  Chul-Hyun Cho; Ki-Cheor Bae; Du-Han Kim
Journal:  Clin Orthop Surg       Date:  2021-08-17

4.  Rotator cuff repair techniques: Current concepts.

Authors:  Tanujan Thangarajah; Ian K Lo; Marlis T Sabo
Journal:  J Clin Orthop Trauma       Date:  2021-03-17

5.  Conventional rotator cuff versus all-suture anchors-A biomechanical study focusing on the insertion angle in an unlimited cyclic model.

Authors:  Dimitris Ntalos; Kay Sellenschloh; Gerd Huber; Daniel Briem; Klaus Püschel; Michael M Morlock; Karl-Heinz Frosch; Florian Fensky; Till Orla Klatte
Journal:  PLoS One       Date:  2019-11-27       Impact factor: 3.240

6.  Initial Experience With a Bioresorbable Polymer Anchor.

Authors:  Robert R Burnham; Jayanth Kumar; Michael Pinzur; Adam Schiff
Journal:  Cureus       Date:  2020-12-29

7.  Clinical and radiological outcomes with PEEK suture anchors used in rotator cuff repair: our experience confirm that a perianchor fluid signal on RM does not affect clinical outcome at one year of follow up.

Authors:  Paolo Di Benedetto; Giovanni Gorasso; Alessandro Beltrame; Francesco Mancuso; Michele Mario Buttironi; Araldo Causero
Journal:  Acta Biomed       Date:  2020-12-30

8.  Mini suture anchor: An effective device for reduction and fixation of displaced temporomandibular joint disc with intracapsular condylar fracture.

Authors:  Shubhechha Shakya; Kai-De Li; Dou Huang; Zuo-Qiang Liu; Zhi-Ru Liu; Lei Liu
Journal:  Chin J Traumatol       Date:  2021-08-18

9.  Biomechanical properties of a suture anchor system from human allogenic mineralized cortical bone matrix for rotator cuff repair.

Authors:  Jakob E Schanda; Barbara Obermayer-Pietsch; Gerhard Sommer; Philipp R Heuberer; Brenda Laky; Christian Muschitz; Klaus Pastl; Eva Pastl; Christian Fialka; Rainer Mittermayr; Johannes Grillari; Ines Foessl
Journal:  BMC Musculoskelet Disord       Date:  2022-05-05       Impact factor: 2.562

Review 10.  Interference Screws Are Biomechanically Superior to Suture Anchors for Medial Patellofemoral Ligament Reconstruction: A Systematic Review and Meta-Analysis.

Authors:  Sean B Sequeira; Casey Imbergamo; Heath P Gould
Journal:  Arthrosc Sports Med Rehabil       Date:  2022-06-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.