Literature DB >> 30488112

Dual-energy CT in early acute pancreatitis: improved detection using iodine quantification.

Simon S Martin1,2, Franziska Trapp1, Julian L Wichmann3, Moritz H Albrecht1, Lukas Lenga1, James Durden2, Christian Booz1, Thomas J Vogl1, Tommaso D'Angelo1,4.   

Abstract

OBJECTIVES: To evaluate the diagnostic performance of a dual-energy computed tomography (DECT)-based technique using iodine quantification and fat fraction analysis for the diagnosis of early acute pancreatitis
METHODS: In this retrospective study, 45 patients (35 men and 10 women; mean age, 54.9 ± 14.0 years) with early acute pancreatitis were included. Serum lipase levels and follow-up examinations served as the reference standard. A matched control group (n = 45) was assembled for evaluation of material decomposition values of normal pancreatic parenchyma. Three blinded radiologists independently interpreted all cases on conventional grayscale DECT series. In addition, readers re-evaluated all cases by manually performing region-of-interest (ROI) measurements on pancreatic-phase DECT material density images of the head, body, and tail of each patient's pancreas. Receiver operating characteristic (ROC) curve analysis was performed to estimate the optimal threshold for discriminating between inflammatory and normal pancreas parenchyma.
RESULTS: DECT-based iodine density values showed significant differences between inflammatory (1.8 ± 0.3 mg/mL) and normal pancreatic parenchyma (2.7 ± 0.7 mg/mL) (p ≤ 0.01). Fat fraction measurements showed no significant differences (p = 0.08). The optimal iodine density threshold for the diagnosis of acute pancreatitis was 2.1 mg/mL with a sensitivity of 96% and specificity of 77%. Iodine quantification revealed an area under the curve (AUC) of 0.86, significantly higher compared to standard image evaluation of the radiologists (AUC, 0.80; sensitivity, 78%; specificity, 82%) (p < 0.01).
CONCLUSION: DECT using iodine quantification allows for diagnosis of early acute pancreatitis with higher sensitivity compared to standard image evaluation. KEY POINTS: • Iodine density values showed significant differences between inflammatory and normal pancreatic parenchyma. • DECT using iodine quantification allows for diagnosis of early acute pancreatitis. • An iodine density of ≤ 2.1 mg/mL optimizes the diagnosis of acute pancreatitis.

Entities:  

Keywords:  Diagnostic imaging; Iodine; Multidetector computed tomography; Pancreas; Pancreatitis

Mesh:

Substances:

Year:  2018        PMID: 30488112     DOI: 10.1007/s00330-018-5844-x

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  32 in total

1.  Diagnostic accuracy of dual-energy CT-based nomograms to predict lymph node metastasis in gastric cancer.

Authors:  Jing Li; Mengjie Fang; Rui Wang; Di Dong; Jie Tian; Pan Liang; Jie Liu; Jianbo Gao
Journal:  Eur Radiol       Date:  2018-06-04       Impact factor: 5.315

2.  Overinterpretation and misreporting of diagnostic accuracy studies: evidence of "spin".

Authors:  Eleanor A Ochodo; Margriet C de Haan; Johannes B Reitsma; Lotty Hooft; Patrick M Bossuyt; Mariska M G Leeflang
Journal:  Radiology       Date:  2013-01-29       Impact factor: 11.105

3.  Comprehensive Comparison of Virtual Monoenergetic and Linearly Blended Reconstruction Techniques in Third-Generation Dual-Source Dual-Energy Computed Tomography Angiography of the Thorax and Abdomen.

Authors:  Moritz H Albrecht; Jesko Trommer; Julian L Wichmann; Jan-Erik Scholtz; Simon S Martin; Thomas Lehnert; Thomas J Vogl; Boris Bodelle
Journal:  Invest Radiol       Date:  2016-09       Impact factor: 6.016

4.  A comparative evaluation of radiologic and clinical scoring systems in the early prediction of severity in acute pancreatitis.

Authors:  Thomas L Bollen; Vikesh K Singh; Rie Maurer; Kathryn Repas; Hendrik W van Es; Peter A Banks; Koenraad J Mortele
Journal:  Am J Gastroenterol       Date:  2011-12-20       Impact factor: 10.864

Review 5.  The revised Atlanta classification of acute pancreatitis: its importance for the radiologist and its effect on treatment.

Authors:  Ruedi F Thoeni
Journal:  Radiology       Date:  2012-03       Impact factor: 11.105

Review 6.  A clinically based classification system for acute pancreatitis. Summary of the International Symposium on Acute Pancreatitis, Atlanta, Ga, September 11 through 13, 1992.

Authors:  E L Bradley
Journal:  Arch Surg       Date:  1993-05

7.  Single-source dual-energy spectral multidetector CT of pancreatic adenocarcinoma: optimization of energy level viewing significantly increases lesion contrast.

Authors:  B N Patel; J V Thomas; M E Lockhart; L L Berland; D E Morgan
Journal:  Clin Radiol       Date:  2012-08-11       Impact factor: 2.350

8.  Classification of acute pancreatitis--2012: revision of the Atlanta classification and definitions by international consensus.

Authors:  Peter A Banks; Thomas L Bollen; Christos Dervenis; Hein G Gooszen; Colin D Johnson; Michael G Sarr; Gregory G Tsiotos; Santhi Swaroop Vege
Journal:  Gut       Date:  2012-10-25       Impact factor: 23.059

9.  Dual-Phase Dual-Energy CT in Patients Treated with Erlotinib for Advanced Non-Small Cell Lung Cancer: Possible Benefits of Iodine Quantification in Response Assessment.

Authors:  Jan Baxa; Tana Matouskova; Gabriela Krakorova; Bernhard Schmidt; Thomas Flohr; Martin Sedlmair; Jiri Bejcek; Jiri Ferda
Journal:  Eur Radiol       Date:  2015-11-12       Impact factor: 5.315

10.  Dual-energy multidetector CT for the characterization of incidental adrenal nodules: diagnostic performance of contrast-enhanced material density analysis.

Authors:  Achille Mileto; Rendon C Nelson; Daniele Marin; Kingshuk Roy Choudhury; Lisa M Ho
Journal:  Radiology       Date:  2014-09-10       Impact factor: 11.105

View more
  2 in total

1.  Dual-energy CT with virtual monoenergetic images and iodine maps improves tumor conspicuity in patients with pancreatic ductal adenocarcinoma.

Authors:  Hongwei Liang; Yang Zhou; Qiao Zheng; Gaowu Yan; Hongfan Liao; Silin Du; Xiaohui Zhang; Fajin Lv; Zhiwei Zhang; Yong-Mei Li
Journal:  Insights Imaging       Date:  2022-09-24

Review 2.  Virtual non-calcium dual-energy CT: clinical applications.

Authors:  Tommaso D'Angelo; Moritz H Albrecht; Danilo Caudo; Silvio Mazziotti; Thomas J Vogl; Julian L Wichmann; Simon Martin; Ibrahim Yel; Giorgio Ascenti; Vitali Koch; Giuseppe Cicero; Alfredo Blandino; Christian Booz
Journal:  Eur Radiol Exp       Date:  2021-09-03
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.