A deep learning model for the detection of both advanced and early glaucoma using fundus photography.

Jin Mo Ahn1, Sangsoo Kim1, Kwang-Sung Ahn2, Sung-Hoon Cho2, Kwan Bok Lee3, Ungsoo Samuel Kim3,4.   

Abstract

PURPOSE: To build a deep learning model to diagnose glaucoma using fundus photography.
DESIGN: Cross sectional case study Subjects, Participants and Controls: A total of 1,542 photos (786 normal controls, 467 advanced glaucoma and 289 early glaucoma patients) were obtained by fundus photography.
METHOD: The whole dataset of 1,542 images were split into 754 training, 324 validation and 464 test datasets. These datasets were used to construct simple logistic classification and convolutional neural network using Tensorflow. The same datasets were used to fine tune pre-trained GoogleNet Inception v3 model.
RESULTS: The simple logistic classification model showed a training accuracy of 82.9%, validation accuracy of 79.9% and test accuracy of 77.2%. Convolutional neural network achieved accuracy and area under the receiver operating characteristic curve (AUROC) of 92.2% and 0.98 on the training data, 88.6% and 0.95 on the validation data, and 87.9% and 0.94 on the test data. Transfer-learned GoogleNet Inception v3 model achieved accuracy and AUROC of 99.7% and 0.99 on training data, 87.7% and 0.95 on validation data, and 84.5% and 0.93 on test data.
CONCLUSION: Both advanced and early glaucoma could be correctly detected via machine learning, using only fundus photographs. Our new model that is trained using convolutional neural network is more efficient for the diagnosis of early glaucoma than previously published models.

Entities:  

Mesh:

Year:  2018        PMID: 30481205      PMCID: PMC6258525          DOI: 10.1371/journal.pone.0207982

Source DB:  PubMed          Journal:  PLoS One        ISSN: 1932-6203            Impact factor:   3.240


Introduction

Machine learning is a system of artificial computer intelligence that provides computers with the ability to automatically learn without being programmed. In the healthcare sector, machine learning has been used to investigate skin cancer classification, to evaluate complex genetic interactions in autism, and to perform monitoring within the intensive care unit [1-3]. A recent study of diabetic retinopathy using deep machine learning revealed that machine learning exhibited high sensitivity and specificity for the detection of diabetic retinopathy [4]. Glaucoma is a progressive optic nerve disorder consisting of various optic disc changes, such as the notching of neuroretinal rims and enlarged optic disc cupping. Notably, glaucoma is one of the leading causes of blindness [5]. Thus, an effective, early investigation of optic disc changes is important in the diagnosis of glaucoma. Several reports have proven the efficacy of machine learning in the early detection of glaucoma [6-9]. However, the previous reports have utilized optical coherence tomography (OCT), red-free retinal-nerve-fiber-layer (RNFL) photography, or visual field tests. In the clinic, fundus photography is the most familiar and easiest test. Therefore, we investigated the efficacy of machine learning and deep learning for detection of both advanced and early glaucoma, using only fundus photography. Firstly, we have used logistic classification, a traditional machine learning technique, to check the performance on discriminating glaucoma patients from normal control. Secondly, we have used GoogleNet Inception v3[10], a pre-trained model, for transfer learning of our data to check the efficacy of deep learning. Finally, we have constructed our own convolutional neural network and compared the performance.

Methods

Data preparation

Fundus photographs of normal and glaucoma patients were collected from Kim’s Eye Hospital. Fundus photography was performed using a non-mydriatic auto fundus camera (AFC-330, Nidek, Japan). A total of 1,542 photos were obtained, including 786 photos from normal patients and 756 photos from 467 advanced and 289 early glaucoma patients. These photos had different sizes, and thus were scaled to have fixed width size of 800 pixels. In order to produce a fixed size input necessary for machine learning models, the photos were cropped at the region of optic nerve with size of 240X240pixels. The normal patients exhibited normal findings on red-free RNFL photography (Vx-10; Kowa Optimed, Inc., Tokyo, Japan), OCT (Cirrus HD-OCT, Carl Zeiss Meditec Inc., Dublin, CA), and visual field test (Humphrey 740 visual field analyzer, Carl Zeiss Meditec Inc., Dublin, CA). The inclusion criteria of the glaucoma patients were as follows: typical glaucomatous visual field defects, and/or bundle defects of RNFLs on HD-OCT, and/or bundle defects of RNFLs on red-free RNFL photography. Among 756 glaucoma patients, 467 cases were in advanced stage (near total cupping of the optic nerve, with or without severe visual field loss within 10° of fixation), and 289 cases were early glaucoma (glaucomatous RNFL defects in red-free RNFL photography, without visual field defects. The classification of early glaucoma and advanced glaucoma was determined by agreement of two specialists. For the classification of glaucoma images from normal images even with the presence of early glaucoma images, the entire set of 1,542 images were split into 754 training, 324 validation, and 464 test datasets (images) (Table 1). The test dataset comprises about 30% of the whole dataset. The remaining dataset was split to about 70% training and 30% validation datasets. The study was approved by the Institutional Review Board of Kim’s Eye Hospital and was conducted in accordance with the tenets of the Declaration of Helsinki.
Table 1

Sample numbers for the machine learning.

Advanced GlaucomaEarly GlaucomaNormalTotal
Entire Data4672897861,542
Training Data228141385754
Validation Data9861165324
Test Data14187236464

Logistic classification

Since fundus photographs are color images, they consist of three-dimensional arrays (240×240×3). To perform logistic regression, images were flattened into a one-dimensional array of 1×(240×240×3). A single layer of weights was used to produce logits; the softmax function was applied to obtain the probability of being classified as a normal or advanced glaucoma image. These probabilities were compared to one-hot encoded labels and loss was calculated using cross entropy. A gradient descent optimizer, with a learning rate of 0.5, was used for optimization. Fig 1 shows the detailed architecture. The model was constructed using Google’s Tensorflow deep learning framework[11].
Fig 1

Logistic classification model architecture: A schematic view of the logistic classification model used in this study.

Flattened fundus photography refers to transformation of three-dimensional array photography to a one-dimensional array in order to perform logistic regression and produce logits.

Logistic classification model architecture: A schematic view of the logistic classification model used in this study.

Flattened fundus photography refers to transformation of three-dimensional array photography to a one-dimensional array in order to perform logistic regression and produce logits.

Convolutional Neural Network (CNN)

Data augmentation

Since the images comprised a small dataset, we applied augmentation to each image to overcome overfitting. Each image was cropped at all four corners, as well as in the middle, to generate five images with fixed size of 224X224. This cropping process was repeated after flipping the image, thereby generating 10 images per photograph. Data augmentation can help overcome overfitting by showing the computer an image from various views to aid in making a decision[12].

Training model

We used a GoogleNet Inception v3 pre-trained model for transfer learning, which included training our data with a predefined (trained) existing model. We modified the last classification layer of the Inception v3 model to fit our classification needs, and then fine-tuned using our data. For backpropagation, the Adam optimizer, an adaptive learning rate method, was used as an optimization function, while cross entropy was used as a loss function. Fig 2 shows the original architecture of the Inception v3 model.
Fig 2

Google Inception v3 architecture: A schematic view of the Inception v3 model.

Each layer consists of an inception module along with merging, and a fully connected layer at the end.

Google Inception v3 architecture: A schematic view of the Inception v3 model.

Each layer consists of an inception module along with merging, and a fully connected layer at the end. We also constructed our own Convolutional Neural Network, using Google’s Tensorflow as backend. Two convolutional layers, with patch sizes of 2020 and 4040, were used with a stride of 1 and depths of 16 and 32. Max pooling was applied, with a patch size of 22 and a stride of 2. Two hidden layers, with 32 and 64 hidden units, were used as fully connected layers. A dropout rate of 0.5 was used in convolutional and fully connected layers to overcome overfitting; ReLu (Rectifier Linear unit) was used as an activation function. For backpropagation, cross entropy was used as a loss function and the Adagrad optimizer was used as an optimization function. All weights were initialized using the Xavier initializer[13]. Fig 3 shows the architecture of our model.
Fig 3

Convolutional neural network architecture: A schematic view of our convolutional neural network used in this study.

It consists of three convolutional layers with max pooling applied at each layer, along with two fully connected layers.

Convolutional neural network architecture: A schematic view of our convolutional neural network used in this study.

It consists of three convolutional layers with max pooling applied at each layer, along with two fully connected layers.

Evaluation

Our models accept an image as input and output the probability that the image represents a photograph of a glaucoma or normal patient. Since we have used augmented data (10 images per photography), we generate 10 probabilities from a single image. By averaging this probability, we can obtain the single probability that the image represents a glaucoma or normal patient, based on each image (Fig 4). Using this strategy, we have evaluated our own model and GoogleNet Inception v3 model based on ROC (receiver operating characteristic) curve by calculating sensitivity and specificity of the models. Moreover, we measured the area under the ROC curve (AUC) as our performance indicator.
Fig 4

Overview of evaluation strategy: A schematic view of our convolutional neural network evaluation strategy.

The probability for each augmented image is outputted by our model and averaged for the final evaluation.

Overview of evaluation strategy: A schematic view of our convolutional neural network evaluation strategy.

The probability for each augmented image is outputted by our model and averaged for the final evaluation.

Results

Traditional machine learning (Logistic classification) approach

Our simple logistic classification model exhibited a training accuracy of 82.9%, a validation accuracy of 79.9% and a test accuracy of 77.2%. To check whether logistic classification model can discriminate advanced glaucoma from normal control without early glaucoma images, advanced glaucoma images were selected from entire dataset to be used to train the logistic classification model. Among 756 glaucoma images, 467 images were advanced glaucoma. 495 normal images were also selected from 786 normal images to avoid imbalanced data problem. About 30% of the 467 advanced glaucoma images and 495 normal control images were randomly split into the test dataset. This resulted in training accuracy of 99.7% and test accuracy of 98.6%. We also checked whether logistic classification model can discriminate early glaucoma from normal control without advanced glaucoma images. Among 756 glaucoma images, 289 images were early glaucoma. 289 normal images were selected from 786 normal images to avoid imbalanced data problem. About 30% of the 289 early glaucoma images and 289 normal control images were randomly split into the test dataset. This resulted in training accuracy of 83.7% and test accuracy of 73.0% (Table 2). This suggests the needs of complex algorithm such as deep learning technique to discriminate both advanced glaucoma and early glaucoma from normal control.
Table 2

Evaluation of the simple logistic classification model.

Advancedand Early GlaucomaAdvancedGlaucoma onlyEarly Glaucoma only
Training Data82.9%99.7%83.7%
Test Data77.2%98.6%73%

Deep learning (convolutional neural network) approach

Table 3 shows summarized results from our own model and from the Inception v3 model. Accuracy refers to the raw accuracy of augmented data, whereas average accuracy refers to ensemble predicted accuracy (Fig 4). Inception v3 transfer learning model achieved accuracy and AUC of 99.7% and 0.99, respectively, on the training data, 87.7% and 0.95 on the validation data, and 84.5% and 0.93 on the test data. To improve test accuracy, we have developed our own convolutional neural network model. In order to build a new model, we have tuned manually various combinations of the hyper-parameters such as convolution patch size, strides, filter size, number of convolution layers, number of fully connected layers, number of hidden nodes, which optimizer to use, learning rate and so on. Our final model achieved accuracy and AUC of 92.2% and 0.98 on the training data, 88.6% and 0.95 on the validation data, and 87.9% and 0.94 on the test data. Both our own model and Inception v3 transferred model showed slightly higher ensemble accuracy than raw accuracy. The ROC curve for each model is depicted in Fig 5. The training stage was considered finished when the average loss for each epoch started to increase for the validation data. Our Convolutional Neural Network needed 29 epochs for optimization whereas Inception v3 transferred model needed 14 epochs for optimization.
Table 3

Comparison of our own model (convolutional neural network) and the Inception v3 model.

Our new modelInception v3
Raw accuracyAverage accuracyAUROCRaw accuracyAverage accuracyAUROC
Training data91.7%92.2%0.9899.7%99.7%0.99
Validation data88.6%88.6%0.9587.0%87.7%0.95
Test Data86.9%87.9%0.9483.9%84.5%0.93
Number of Epochs2914
Fig 5

Comparative of classification performance between our Convolutional Neural Network (CNN) model and the Inception v3 model.

Receiver Operating Characteristic curve for our CNN model and the transfer-learned Inception v3 model. Blue dotted line represents the training data, red dotted line represents the validation data, and yellow line represents the test data.

Comparative of classification performance between our Convolutional Neural Network (CNN) model and the Inception v3 model.

Receiver Operating Characteristic curve for our CNN model and the transfer-learned Inception v3 model. Blue dotted line represents the training data, red dotted line represents the validation data, and yellow line represents the test data.

Discussion

This study demonstrates that deep learning techniques can be combined with fundus photography as an effective approach to distinguish between normal controls and glaucoma patients, even at early stages. A simple traditional machine learning approach, such as logistic classification, was sufficient for classifying advanced glaucoma patients. However, discrimination of both advanced glaucoma and early glaucoma from normal control required a complex deep learning approach, such as CNN. Using a complex deep learning model yields a vast array of parameters that may cause overfitting of the training data. Thus, we incorporated regularization techniques, such as dropout and data augmentation. Dropout randomly corrupts hidden nodes, which are passed to the succeeding layers. Since this process is random, the detailed architecture of the model changes at each iteration of training, leading to a generalized model with a sufficient number of training iterations. Data augmentation allows the machine to learn an image from a different view; using this approach, we generated 10 images per fundus photograph and averaged the results for the final evaluation. This ensemble prediction process yielded an improved model (Table 3). Transfer learning, using the Google Inception v3 model, required less epochs for training than our CNN model. Since transfer learning requires the use of an existing trained model, all the parameters that are provided within Inception v3 were used as initial parameters[14]. Notably, these parameters have already been optimized for detecting natural images, such as edges and curves, and may require fewer epochs for optimization than a model that began from random parameters. Further, considering that the Inception v3 models are trained using extremely large numbers of images (approximately 1.28 million images), the initial convolutional patches are more generalized at detecting features; thus, these will provide a more generalized model when trained with small amounts of data. In the case of large volume data, it may take a long time to build and optimize a new model. Therefore, many studies on developing image classification model, have used transfer learning based on the state of the art Convolutional Neural Network models [1,15,16]. These models include GoogleNet Inception v3, Very Deep Convolution Network from Visual Geometry group(VGG)[17] and ResNet[18]. Recent study using large scale fundus photography used ensemble of AlexNet[19], VGG and Inception v3 transferred learned model to classify age related eye disease[20]. While transfer learning is an attractive option in building image classification model regardless of how big the data is, an alternative strategy for a small scale data would be to develop one’s own convolutional neural network model with a simpler architecture. In fact, our convolutional neural network model with far less parameters worked slightly better than the Google Inception v3 transfer learning model in terms of test accuracy (Table 3). This may be due to complexity of the Inception v3 algorithm. Since our purpose is to discriminate glaucoma and normal control, a model architecture like Inception v3, which is designed to classify 1000 categories, can be too heavy. On the other hand, our model, which was specifically tuned in terms of architecture for binary classification of glaucoma and normal control, showed improved test accuracy on a small scale. However, many trials and errors, along with a substantial amount of hyper-parameter tuning time, were required to build a new, optimized model. Due to the complexity of neural network and many feature maps created during training time, further analysis is required to explain why a machine-trained model classified the image as a glaucoma or normal patient. Such analysis can be performed by viewing the image after each convolutional layer, along with plotting the image using a technique such as t-distributed Stochastic Neighboring Embedding (t-SNE)[21]. However, this method does not provide a score of variable importance, as in the random forest technique; thus, it may require an expert assistance. Kim et al[22]. reported that the classification accuracy, sensitivity, specificity, and AUC for glaucoma, using machine learning, were 0.98, 0.983, 0.975, and 0.979, respectively. However, their study used multimodal imaging, including fundus photography, red-free fundus photography, visual field testing, and spectral domain OCT. While their study showed higher accuracy, sensitivity, and AUC than the present study, the latter used only fundus photography, achieving similar accuracy in cases of advanced glaucoma and only a slight difference in cases of early glaucoma. In conclusion, deep learning using only fundus photography could be an ancillary test for the diagnosis of glaucoma. In addition, if the algorithm becomes more sophisticated, it may serve as a robust aid for detection of the early stages of glaucoma.
  11 in total

1.  A Deep Learning Algorithm for Prediction of Age-Related Eye Disease Study Severity Scale for Age-Related Macular Degeneration from Color Fundus Photography.

Authors:  Felix Grassmann; Judith Mengelkamp; Caroline Brandl; Sebastian Harsch; Martina E Zimmermann; Birgit Linkohr; Annette Peters; Iris M Heid; Christoph Palm; Bernhard H F Weber
Journal:  Ophthalmology       Date:  2018-04-10       Impact factor: 12.079

2.  Prevalence, Risk Factors, and Visual Features of Undiagnosed Glaucoma: The Singapore Epidemiology of Eye Diseases Study.

Authors:  Jacqueline Chua; Mani Baskaran; Peng Guan Ong; Yingfeng Zheng; Tien Yin Wong; Tin Aung; Ching-Yu Cheng
Journal:  JAMA Ophthalmol       Date:  2015-08       Impact factor: 7.389

3.  Development and Validation of a Deep Learning Algorithm for Detection of Diabetic Retinopathy in Retinal Fundus Photographs.

Authors:  Varun Gulshan; Lily Peng; Marc Coram; Martin C Stumpe; Derek Wu; Arunachalam Narayanaswamy; Subhashini Venugopalan; Kasumi Widner; Tom Madams; Jorge Cuadros; Ramasamy Kim; Rajiv Raman; Philip C Nelson; Jessica L Mega; Dale R Webster
Journal:  JAMA       Date:  2016-12-13       Impact factor: 56.272

4.  Dermatologist-level classification of skin cancer with deep neural networks.

Authors:  Andre Esteva; Brett Kuprel; Roberto A Novoa; Justin Ko; Susan M Swetter; Helen M Blau; Sebastian Thrun
Journal:  Nature       Date:  2017-01-25       Impact factor: 49.962

5.  Comparing machine learning classifiers for diagnosing glaucoma from standard automated perimetry.

Authors:  Michael H Goldbaum; Pamela A Sample; Kwokleung Chan; Julia Williams; Te-Won Lee; Eytan Blumenthal; Christopher A Girkin; Linda M Zangwill; Christopher Bowd; Terrence Sejnowski; Robert N Weinreb
Journal:  Invest Ophthalmol Vis Sci       Date:  2002-01       Impact factor: 4.799

6.  Machine learning classifiers for glaucoma diagnosis based on classification of retinal nerve fibre layer thickness parameters measured by Stratus OCT.

Authors:  Dimitrios Bizios; Anders Heijl; Jesper Leth Hougaard; Boel Bengtsson
Journal:  Acta Ophthalmol       Date:  2010-01-08       Impact factor: 3.761

7.  Gaussian processes for personalized e-health monitoring with wearable sensors.

Authors:  Lei Clifton; David A Clifton; Marco A F Pimentel; Peter J Watkinson; Lionel Tarassenko
Journal:  IEEE Trans Biomed Eng       Date:  2013-01       Impact factor: 4.538

8.  Comparison of machine learning and traditional classifiers in glaucoma diagnosis.

Authors:  Kwokleung Chan; Te-Won Lee; Pamela A Sample; Michael H Goldbaum; Robert N Weinreb; Terrence J Sejnowski
Journal:  IEEE Trans Biomed Eng       Date:  2002-09       Impact factor: 4.538

9.  Development of machine learning models for diagnosis of glaucoma.

Authors:  Seong Jae Kim; Kyong Jin Cho; Sejong Oh
Journal:  PLoS One       Date:  2017-05-23       Impact factor: 3.240

10.  Glaucoma Diagnostic Accuracy of Machine Learning Classifiers Using Retinal Nerve Fiber Layer and Optic Nerve Data from SD-OCT.

Authors:  Kleyton Arlindo Barella; Vital Paulino Costa; Vanessa Gonçalves Vidotti; Fabrício Reis Silva; Marcelo Dias; Edson Satoshi Gomi
Journal:  J Ophthalmol       Date:  2013-11-28       Impact factor: 1.909

View more
  26 in total

1.  An Ophthalmologist's Guide to Deciphering Studies in Artificial Intelligence.

Authors:  Daniel S W Ting; Aaron Y Lee; Tien Y Wong
Journal:  Ophthalmology       Date:  2019-09-21       Impact factor: 12.079

2.  Automatic detection of leakage point in central serous chorioretinopathy of fundus fluorescein angiography based on time sequence deep learning.

Authors:  Menglu Chen; Kai Jin; Kun You; Yufeng Xu; Yao Wang; Chee-Chew Yip; Jian Wu; Juan Ye
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-04-12       Impact factor: 3.117

3.  Classification of Glaucoma Stages Using Image Empirical Mode Decomposition from Fundus Images.

Authors:  Deepak Parashar; Dheraj Kumar Agrawal
Journal:  J Digit Imaging       Date:  2022-05-17       Impact factor: 4.903

4.  Artificial Intelligence for Glaucoma: Creating and Implementing Artificial Intelligence for Disease Detection and Progression.

Authors:  Lama A Al-Aswad; Rithambara Ramachandran; Joel S Schuman; Felipe Medeiros; Malvina B Eydelman
Journal:  Ophthalmol Glaucoma       Date:  2022-02-24

5.  Attention-Guided 3D-CNN Framework for Glaucoma Detection and Structural-Functional Association Using Volumetric Images.

Authors:  Yasmeen George; Bhavna J Antony; Hiroshi Ishikawa; Gadi Wollstein; Joel S Schuman; Rahil Garnavi
Journal:  IEEE J Biomed Health Inform       Date:  2020-12-04       Impact factor: 5.772

6.  Improving convolutional neural networks performance for image classification using test time augmentation: a case study using MURA dataset.

Authors:  Ibrahem Kandel; Mauro Castelli
Journal:  Health Inf Sci Syst       Date:  2021-07-31

7.  The ImageJ ecosystem: Open-source software for image visualization, processing, and analysis.

Authors:  Alexandra B Schroeder; Ellen T A Dobson; Curtis T Rueden; Pavel Tomancak; Florian Jug; Kevin W Eliceiri
Journal:  Protein Sci       Date:  2020-11-20       Impact factor: 6.725

8.  Automatic detection of coronavirus disease (COVID-19) using X-ray images and deep convolutional neural networks.

Authors:  Ali Narin; Ceren Kaya; Ziynet Pamuk
Journal:  Pattern Anal Appl       Date:  2021-05-09       Impact factor: 2.580

Review 9.  Transfer learning for medical image classification: a literature review.

Authors:  Mate E Maros; Thomas Ganslandt; Hee E Kim; Alejandro Cosa-Linan; Nandhini Santhanam; Mahboubeh Jannesari
Journal:  BMC Med Imaging       Date:  2022-04-13       Impact factor: 1.930

10.  Convex Representations Using Deep Archetypal Analysis for Predicting Glaucoma.

Authors:  Anshul Thakur; Michael Goldbaum; Siamak Yousefi
Journal:  IEEE J Transl Eng Health Med       Date:  2020-05-28
View more