| Literature DB >> 30453513 |
Mihai Musteata1, Denis Gabriel Borcea2, Raluca Ștefănescu3, Gheorghe Solcan4, Radu Lăcătuș5.
Abstract
Electroencephalography (EEG) is an objective diagnostic tool in the evaluation of cerebral functionality, both in human and veterinary medicine. For EEG acquisition, different types of electrodes are used, as long as they have no impact on the recorded background activity. However, to date, the influence of electrode type on quantitative EEG and cerebral coherence has not been investigated. Twenty EEG traces (ten with needle electrodes and ten with disk electrodes) were recorded from ten mesocephalic vigil dogs in a monopolar montage. Values for interhemispheric coherence for each frequency band were compared between stainless needle and silver disk electrodes traces. Our results show that the values of interhemispheric coherence in vigil dogs are depending of the type of electrodes used in EEG recordings. In the frontal (FP) channel, for delta and theta frequency bands, the registered coherence is significantly higher when stainless needle electrodes are used. Our results might have important consequences in the field of canine neurology and applied neuroscience, as the frontal channel analysis is preferred in aging and behavior studies.Entities:
Keywords: dog; electrodes; electroencephalography
Mesh:
Substances:
Year: 2018 PMID: 30453513 PMCID: PMC6264086 DOI: 10.3390/s18113990
Source DB: PubMed Journal: Sensors (Basel) ISSN: 1424-8220 Impact factor: 3.576
Figure 1Mean and standard error of dominant frequency for each channel ((a) frontal—FP; (b) central—C, (c) temporal—T; (d) occipital—O) and frequency bands related with the type of electrode used in the electroencephalography (EEG) acquisition. No statistical differences (p > 0.05) were observed between the obtained values of DF (dominant frequency).
Mean of dominant frequency in all frequency bands relative to the electrode.
| Frequency Band | Channel | Disk | Needle | |
|---|---|---|---|---|
| Delta | FP1FP2 | 2.207 ± 0.997 | 2.185 ± 1.250 | 0.941 |
| C3C4 | 2.423 ± 0.940 | 2.493 ± 1.188 | 0.569 | |
| O1O2 | 2.331 ± 1.170 | 1.973 ± 1.149 | 0.222 | |
| T3T4 | 2.940 ± 1.061 | 2.724 ± 1.157 |
| |
| Theta | FP1FP2 | 5.384 ± 1.192 | 5.895 ± 1.268 | 0.113 |
| C3C4 | 5.727 ± 1.512 | 5.824 ± 1.409 | 0.695 | |
| O1O2 | 5.598 ± 1.532 | 5.488 ± 1.317 | 0.491 | |
| T3T4 | 5.813 ± 1.689 | 5.450 ± 1.220 | 0.214 | |
| Alpha | FP1FP2 | 10.992 ± 1.458 | 9.672 ± 1.444 |
|
| C3C4 | 11.111 ± 1.945 | 10.507 ± 1.834 | 0.234 | |
| O1O2 | 11.201 ± 1.764 | 11.232 ± 1.671 | 0.801 | |
| T3T4 | 11.489 ± 1.716 | 10.781 ± 2.080 | 0.158 | |
| Beta LF | FP1FP2 | 17.332 ± 1.798 | 16.918 ± 1.771 | 0.280 |
| C3C4 | 16.436 ± 1.913 | 16.636 ± 1.683 | 0.604 | |
| O1O2 | 16.808 ± 1.700 | 17.037 ± 1.471 | 0.717 | |
| T3T4 | 17.211 ± 1.617 | 16.273 ± 2.265 | 0.099 | |
| Beta HF | FP1FP2 | 24.360 ± 3.649 | 27.305 ± 4.674 |
|
| C3C4 | 26.701 ± 3.842 | 26.818 ± 3.880 | 0.836 | |
| O1O2 | 27.432 ± 4.495 | 26.515 ± 3.874 | 0.548 | |
| T3T4 | 27.854 ± 4.355 | 28.962 ± 3.400 | 0.428 |
Mean interhemispheric coherence in all frequency bands relative to the electrode.
| Frequency Band | Chanel | Disk Coherence | Needle Coherence | |
|---|---|---|---|---|
| Delta | FP1FP2 | 0.372 ± 0.134 | 0.504 ± 0.197 |
|
| C3C4 | 0.332 ± 0.136 | 0.349 ± 0.199 | 0.631 | |
| O1O2 | 0.309 ± 0.119 | 0.336 ± 0.179 | 0.700 | |
| T3T4 | 0.297 ± 0.150 | 0.323 ± 0.172 | 0.620 | |
| Theta | FP1FP2 | 0.371 ± 0.128 | 0.527 ± 0.169 |
|
| C3C4 | 0.361 ± 0.169 | 0.335 ± 0.213 | 0.610 | |
| O1O2 | 0.321 ± 0.144 | 0.302 ± 0.167 | 0.530 | |
| T3T4 | 0.307 ± 0.140 | 0.354 ± 0.180 | 0.183 | |
| Alpha | FP1FP2 | 0.311 ± 0.133 | 0.347 ± 0.133 | 0.249 |
| C3C4 | 0.331 ± 0.148 | 0.253 ± 0.118 |
| |
| O1O2 | 0.326 ± 0.149 | 0.263 ± 0.110 | 0.113 | |
| T3T4 | 0.309 ± 0.141 | 0.278 ± 0.155 | 0.307 | |
| Beta LF | FP1FP2 | 0.299 ± 0.144 | 0.254 ± 0.104 | 0.264 |
| C3C4 | 0.320 ± 0.143 | 0.237 ± 0.096 |
| |
| O1O2 | 0.317 ± 0.141 | 0.248 ± 0.095 | 0.082 | |
| T3T4 | 0.301 ± 0.150 | 0.253 ± 0.111 | 0.329 | |
| Beta HF | FP1FP2 | 0.277 ± 0.139 | 0.256 ± 0.100 | 0.716 |
| C3C4 | 0.299 ± 0.134 | 0.240 ± 0.091 | 0.058 | |
| O1O2 | 0.292 ± 0.134 | 0.256 ± 0.095 | 0.299 | |
| T3T4 | 0.279 ± 0.145 | 0.257 ± 0.097 | 0.733 |
*—channels in which the mean of coherence was superior to the threshold of 0.4.
Figure 2Mean and standard error of interhemispheric coherence observed for needle and disk electrodes in each channel ((a) frontal—FP; (b) central—C, (c) temporal—T; (d) occipital—O) and frequency bands. Dotted line (threshold for medium coherence) is fixed at 0.4 corresponding to a medium coherence. The value of obtained coherence was higher than 0.4 in frontal channel for delta and theta frequency bands only on EEG traces acquired with needle electrodes.