Literature DB >> 25998854

Novel Multipin Electrode Cap System for Dry Electroencephalography.

P Fiedler1, P Pedrosa2, S Griebel3, C Fonseca2, F Vaz4, E Supriyanto5, F Zanow6, J Haueisen7,8.   

Abstract

Current usage of electroencephalography (EEG) is limited to laboratory environments. Self-application of a multichannel wet EEG caps is practically impossible, since the application of state-of-the-art wet EEG sensors requires trained laboratory staff. We propose a novel EEG cap system with multipin dry electrodes overcoming this problem. We describe the design of a novel 24-pin dry electrode made from polyurethane and coated with Ag/AgCl. A textile cap system holds 97 of these dry electrodes. An EEG study with 20 volunteers compares the 97-channel dry EEG cap with a conventional 128-channel wet EEG cap for resting state EEG, alpha activity, eye blink artifacts and checkerboard pattern reversal visual evoked potentials. All volunteers report a good cap fit and good wearing comfort. Average impedances are below 150 kΩ for 92 out of 97 dry electrodes, enabling recording with standard EEG amplifiers. No significant differences are observed between wet and dry power spectral densities for all EEG bands. No significant differences are observed between the wet and dry global field power time courses of visual evoked potentials. The 2D interpolated topographic maps show significant differences of 3.52 and 0.44% of the map areas for the N75 and N145 VEP components, respectively. For the P100 component, no significant differences are observed. Dry multipin electrodes integrated in a textile EEG cap overcome the principle limitations of wet electrodes, allow rapid application of EEG multichannel caps by non-trained persons, and thus enable new fields of application for multichannel EEG acquisition.

Entities:  

Mesh:

Year:  2015        PMID: 25998854     DOI: 10.1007/s10548-015-0435-5

Source DB:  PubMed          Journal:  Brain Topogr        ISSN: 0896-0267            Impact factor:   3.020


  21 in total

1.  MNE Scan: Software for real-time processing of electrophysiological data.

Authors:  Lorenz Esch; Limin Sun; Viktor Klüber; Seok Lew; Daniel Baumgarten; P Ellen Grant; Yoshio Okada; Jens Haueisen; Matti S Hämäläinen; Christoph Dinh
Journal:  J Neurosci Methods       Date:  2018-04-03       Impact factor: 2.390

2.  EEG spectral exponent as a synthetic index for the longitudinal assessment of stroke recovery.

Authors:  J Lanzone; M A Colombo; S Sarasso; F Zappasodi; M Rosanova; M Massimini; V Di Lazzaro; G Assenza
Journal:  Clin Neurophysiol       Date:  2022-03-08       Impact factor: 4.861

3.  Proposing Metrics for Benchmarking Novel EEG Technologies Towards Real-World Measurements.

Authors:  Anderson S Oliveira; Bryan R Schlink; W David Hairston; Peter König; Daniel P Ferris
Journal:  Front Hum Neurosci       Date:  2016-05-10       Impact factor: 3.169

4.  Automatic Removal of Physiological Artifacts in EEG: The Optimized Fingerprint Method for Sports Science Applications.

Authors:  David B Stone; Gabriella Tamburro; Patrique Fiedler; Jens Haueisen; Silvia Comani
Journal:  Front Hum Neurosci       Date:  2018-03-21       Impact factor: 3.169

5.  Carbon nanofiber-filled conductive silicone elastomers as soft, dry bioelectronic interfaces.

Authors:  Geoffrey A Slipher; W David Hairston; J Cortney Bradford; Erich D Bain; Randy A Mrozek
Journal:  PLoS One       Date:  2018-02-06       Impact factor: 3.240

6.  A new ICA-based fingerprint method for the automatic removal of physiological artifacts from EEG recordings.

Authors:  Gabriella Tamburro; Patrique Fiedler; David Stone; Jens Haueisen; Silvia Comani
Journal:  PeerJ       Date:  2018-02-23       Impact factor: 2.984

7.  Special Report on the Impact of the COVID-19 Pandemic on Clinical EEG and Research and Consensus Recommendations for the Safe Use of EEG.

Authors:  Salvatore Campanella; Kemal Arikan; Claudio Babiloni; Michela Balconi; Maurizio Bertollo; Viviana Betti; Luigi Bianchi; Martin Brunovsky; Carla Buttinelli; Silvia Comani; Giorgio Di Lorenzo; Daniel Dumalin; Carles Escera; Andreas Fallgatter; Derek Fisher; Giulia Maria Giordano; Bahar Guntekin; Claudio Imperatori; Ryouhei Ishii; Hendrik Kajosch; Michael Kiang; Eduardo López-Caneda; Pascal Missonnier; Armida Mucci; Sebastian Olbrich; Georges Otte; Andrea Perrottelli; Alessandra Pizzuti; Diego Pinal; Dean Salisbury; Yingying Tang; Paolo Tisei; Jijun Wang; Istvan Winkler; Jiajin Yuan; Oliver Pogarell
Journal:  Clin EEG Neurosci       Date:  2020-09-25       Impact factor: 1.843

8.  Novel bifunctional cap for simultaneous electroencephalography and transcranial electrical stimulation.

Authors:  Sophia Wunder; Alexander Hunold; Patrique Fiedler; Falk Schlegelmilch; Klaus Schellhorn; Jens Haueisen
Journal:  Sci Rep       Date:  2018-05-08       Impact factor: 4.379

9.  Influence of Stainless Needle Electrodes and Silver Disk Electrodes over the Interhemispheric Cerebral Coherence Value in Vigil Dogs.

Authors:  Mihai Musteata; Denis Gabriel Borcea; Raluca Ștefănescu; Gheorghe Solcan; Radu Lăcătuș
Journal:  Sensors (Basel)       Date:  2018-11-16       Impact factor: 3.576

10.  A High-Speed SSVEP-Based BCI Using Dry EEG Electrodes.

Authors:  Xiao Xing; Yijun Wang; Weihua Pei; Xuhong Guo; Zhiduo Liu; Fei Wang; Gege Ming; Hongze Zhao; Qiang Gui; Hongda Chen
Journal:  Sci Rep       Date:  2018-10-02       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.