Literature DB >> 30450732

Non-invasive measurement of reservoir pressure parameters from brachial-cuff blood pressure waveforms.

Xiaoqing Peng1, Martin G Schultz1, Dean S Picone1, Nathan Dwyer1,2, J Andrew Black1,2, Philip Roberts-Thomson1,2, James E Sharman1.   

Abstract

Reservoir pressure parameters [eg, reservoir pressure (RP) and excess pressure (XSP)] are biomarkers derived from blood pressure (BP) waveforms that have been shown to predict cardiovascular events independent of conventional cardiovascular risk markers. However, whether RP and XSP can be derived non-invasively from operator-independent cuff device measured brachial or central BP waveforms has never been examined. This study sought to achieve this by comparison of cuff reservoir pressure parameters with intra-aortic reservoir pressure parameters. 162 participants (aged 61 ± 10 years, 72% male) undergoing coronary angiography had the simultaneous measurement of cuff BP waveforms (via SphygmoCor XCEL, AtCor Medical) and intra-aortic BP waveforms (via fluid-filled catheter). RP and XSP derived from cuff acquired brachial and central BP waveforms were compared with intra-aortic measures. Concordance between brachial-cuff and intra-aortic measurement was moderate-to-good for RP peak (36 ± 11 vs 48 ± 14 mm Hg, P < 0.001; ICC 0.77, 95% CI: 0.71-0.82), and poor-to-moderate for XSP peak (28 ± 10 vs 24 ± 9 mm Hg, P < 0.001; ICC 0.49, 95% CI: 0.35-0.60). Concordance between central-cuff and intra-aortic measurement was moderate-to-good for RP peak (35 ± 9 vs 46 ± 14 mm Hg, P < 0.001; ICC 0.77, 95% CI: 0.70-0.82), but poor for XSP peak (12 ± 3 vs 24 ± 9 mm Hg, P < 0.001; ICC 0.12, 95% CI: -0.13 to 0.31). In conclusion, both brachial-cuff and central-cuff methods can reasonably estimate intra-aortic RP, whereas XSP can only be acceptably derived from brachial-cuff BP waveforms. This should enable widespread application to determine the clinical significance, but there is significant room for refinement of the method. ©2018 Wiley Periodicals, Inc.

Entities:  

Keywords:  arterial blood pressure; hemodynamics; non-invasive; oscillometry; reservoir

Mesh:

Year:  2018        PMID: 30450732      PMCID: PMC8031070          DOI: 10.1111/jch.13411

Source DB:  PubMed          Journal:  J Clin Hypertens (Greenwich)        ISSN: 1524-6175            Impact factor:   3.738


  26 in total

1.  Time-domain representation of ventricular-arterial coupling as a windkessel and wave system.

Authors:  Jiun-Jr Wang; Aoife B O'Brien; Nigel G Shrive; Kim H Parker; John V Tyberg
Journal:  Am J Physiol Heart Circ Physiol       Date:  2002-12-12       Impact factor: 4.733

2.  Validation of the OSCAR 2 oscillometric 24-hour ambulatory blood pressure monitor according to the International Protocol for the validation of blood pressure measuring devices.

Authors:  Stephen C Jones; Mary Bilous; Sue Winship; Paul Finn; James Goodwin
Journal:  Blood Press Monit       Date:  2004-08       Impact factor: 1.444

Review 3.  Wave intensity analysis and the development of the reservoir-wave approach.

Authors:  John V Tyberg; Justin E Davies; Zhibin Wang; William A Whitelaw; Jacqueline A Flewitt; Nigel G Shrive; Darryl P Francis; Alun D Hughes; Kim H Parker; Jiun-Jr Wang
Journal:  Med Biol Eng Comput       Date:  2009-02-03       Impact factor: 2.602

4.  Reservoir and excess pressures predict cardiovascular events in high-risk patients.

Authors:  Bernhard Hametner; Siegfried Wassertheurer; Alun D Hughes; Kim H Parker; Thomas Weber; Bernd Eber
Journal:  Int J Cardiol       Date:  2013-11-23       Impact factor: 4.164

Review 5.  Non-invasive estimation of aortic blood pressures: a close look at current devices and methods.

Authors:  Sandrine Millasseau; Davide Agnoletti
Journal:  Curr Pharm Des       Date:  2015       Impact factor: 3.116

6.  Invasive validation of a novel brachial cuff-based oscillometric device (SphygmoCor XCEL) for measuring central blood pressure.

Authors:  Toshihiro Shoji; Atsushi Nakagomi; Sho Okada; Yuji Ohno; Yoshio Kobayashi
Journal:  J Hypertens       Date:  2017-01       Impact factor: 4.844

7.  Arterial reservoir characteristics and central-to-peripheral blood pressure amplification in the human upper limb.

Authors:  Xiaoqing Peng; Martin G Schultz; Dean S Picone; J Andrew Black; Nathan Dwyer; Philip Roberts-Thomson; Justin E Davies; James E Sharman
Journal:  J Hypertens       Date:  2017-09       Impact factor: 4.844

8.  A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research.

Authors:  Terry K Koo; Mae Y Li
Journal:  J Chiropr Med       Date:  2016-03-31

9.  Direct blood pressure measurement--dynamic response requirements.

Authors:  R M Gardner
Journal:  Anesthesiology       Date:  1981-03       Impact factor: 7.892

10.  Global, regional, and national comparative risk assessment of 79 behavioural, environmental and occupational, and metabolic risks or clusters of risks, 1990-2015: a systematic analysis for the Global Burden of Disease Study 2015.

Authors: 
Journal:  Lancet       Date:  2016-10-08       Impact factor: 79.321

View more
  3 in total

1.  Non-invasive measurement of reservoir pressure parameters from brachial-cuff blood pressure waveforms.

Authors:  Xiaoqing Peng; Martin G Schultz; Dean S Picone; Nathan Dwyer; J Andrew Black; Philip Roberts-Thomson; James E Sharman
Journal:  J Clin Hypertens (Greenwich)       Date:  2018-11-19       Impact factor: 3.738

2.  The modified arterial reservoir: An update with consideration of asymptotic pressure (P) and zero-flow pressure (Pzf).

Authors:  Alun D Hughes; Kim H Parker
Journal:  Proc Inst Mech Eng H       Date:  2020-05-05       Impact factor: 1.617

3.  Cuffless Blood Pressure Measurement Using a Smartphone-Case Based ECG Monitor with Photoplethysmography in Hypertensive Patients.

Authors:  Zhanna Sagirova; Natalia Kuznetsova; Nana Gogiberidze; Daria Gognieva; Aleksandr Suvorov; Petr Chomakhidze; Stefano Omboni; Hugo Saner; Philippe Kopylov
Journal:  Sensors (Basel)       Date:  2021-05-19       Impact factor: 3.576

  3 in total