Literature DB >> 30441464

InstaBP: Cuff-less Blood Pressure Monitoring on Smartphone using Single PPG Sensor.

Jishnu Dey, Aman Gaurav, Vijay N Tiwari.   

Abstract

Cuff-less Blood Pressure (BP) monitoring has gained interest of the research community in recent years, due to its importance in continuous and non-invasive monitoring of BP for early detection of hypertension, thereby reducing mortality. Several approaches that involve photoplethysmography (PPG) and Pulse Transit Time (PTT) have been explored with promising results; however the requirement of two sensors makes them obtrusive for continuous use. Single PPG sensor approaches using machine learning have also been attempted, but there are certain deficiencies in these methods as they go for a one-size-fits-all approach. In this work, we develop an ensemble of BP prediction models based on demographic and physiological partitioning. Also, we incorporate a set of unique PPG features into our models, which results in test accuracies of 5 mmHg Mean Absolute Error (MAE) for Diastolic BP, and 6.9 mmHg MAE for Systolic BP. Given our marked improvement over ubiquitous models (18% for Diastolic BP and 11.5% for Systolic BP), this approach opens up avenues where single PPG sensor based methods can predict BP with a high degree of accuracy. This is a big step towards developing continuous BP monitoring systems, and can help in better management of cardiac health.

Entities:  

Mesh:

Year:  2018        PMID: 30441464     DOI: 10.1109/EMBC.2018.8513189

Source DB:  PubMed          Journal:  Annu Int Conf IEEE Eng Med Biol Soc        ISSN: 2375-7477


  11 in total

1.  Assessment of Blood Pressure Using Only a Smartphone and Machine Learning Techniques: A Systematic Review.

Authors:  Fridolin Haugg; Mohamed Elgendi; Carlo Menon
Journal:  Front Cardiovasc Med       Date:  2022-06-13

Review 2.  Blood pressure measurement using only a smartphone.

Authors:  Lorenz Frey; Carlo Menon; Mohamed Elgendi
Journal:  NPJ Digit Med       Date:  2022-07-06

3.  Mobile Personal Health Care System for Noninvasive, Pervasive, and Continuous Blood Pressure Monitoring: Development and Usability Study.

Authors:  Luis J Mena; Vanessa G Félix; Rodolfo Ostos; Armando J González; Rafael Martínez-Peláez; Jesus D Melgarejo; Gladys E Maestre
Journal:  JMIR Mhealth Uhealth       Date:  2020-07-20       Impact factor: 4.773

4.  Smartphone / smartwatch-based cuffless blood pressure measurement : a position paper from the Korean Society of Hypertension.

Authors:  Hae Young Lee; Dong-Ju Lee; Jongmo Seo; Sang-Hyun Ihm; Kwang-Il Kim; Eun Joo Cho; Hyeon Chang Kim; Jinho Shin; Sungha Park; Il-Suk Sohn; Wook-Jin Chung; Sung Kee Ryu; Ki Chul Sung; Juhan Kim; Dae-Hee Kim; Wook Bum Pyun
Journal:  Clin Hypertens       Date:  2021-01-25

Review 5.  The Advent of Cuffless Mobile Device Blood Pressure Measurement: Remaining Challenges and Pitfalls.

Authors:  Hae-Young Lee; Thilo Burkard
Journal:  Korean Circ J       Date:  2022-03       Impact factor: 3.243

6.  Smartwatch-Based Blood Pressure Measurement Demonstrates Insufficient Accuracy.

Authors:  Maarten Falter; Martijn Scherrenberg; Karen Driesen; Zoë Pieters; Toshiki Kaihara; Linqi Xu; Enrico Gianluca Caiani; Paolo Castiglioni; Andrea Faini; Gianfranco Parati; Paul Dendale
Journal:  Front Cardiovasc Med       Date:  2022-07-11

Review 7.  Advances in Cuffless Continuous Blood Pressure Monitoring Technology Based on PPG Signals.

Authors:  Caijie Qin; Xiaohua Wang; Guangjun Xu; Xibo Ma
Journal:  Biomed Res Int       Date:  2022-10-01       Impact factor: 3.246

Review 8.  Cuffless Single-Site Photoplethysmography for Blood Pressure Monitoring.

Authors:  Manish Hosanee; Gabriel Chan; Kaylie Welykholowa; Rachel Cooper; Panayiotis A Kyriacou; Dingchang Zheng; John Allen; Derek Abbott; Carlo Menon; Nigel H Lovell; Newton Howard; Wee-Shian Chan; Kenneth Lim; Richard Fletcher; Rabab Ward; Mohamed Elgendi
Journal:  J Clin Med       Date:  2020-03-07       Impact factor: 4.241

9.  Cuff-Less Blood Pressure Prediction from ECG and PPG Signals Using Fourier Transformation and Amplitude Randomization Preprocessing for Context Aggregation Network Training.

Authors:  Treesukon Treebupachatsakul; Apivitch Boosamalee; Siratchakrit Shinnakerdchoke; Suejit Pechprasarn; Nuntachai Thongpance
Journal:  Biosensors (Basel)       Date:  2022-03-04

Review 10.  Wearable blood pressure measurement devices and new approaches in hypertension management: the digital era.

Authors:  D Konstantinidis; P Iliakis; F Tatakis; K Thomopoulos; K Dimitriadis; D Tousoulis; K Tsioufis
Journal:  J Hum Hypertens       Date:  2022-03-23       Impact factor: 3.012

View more