Head-to-head comparison of two continuous glucose monitoring systems on a cardio-surgical ICU.

M A Punke1, C Decker2, M Petzoldt3, D A Reuter3, K H Wodack3, H Reichenspurner4, M Kubik2, S Kluge2.   

Abstract

In critical illness hypo-and hyperglycemia have a negative influence on patient outcome. Continuous glucose monitoring (CGM) could help in early detection of hypo-and hyperglycemia. A requirement for these new methods is an acceptable accuracy and precision in clinical practice. In this pilot study we prospectively evaluated the accuracy and precision of two CGM sensors (subcutaneous sensor: Sentrino®, Medtronic and intravasal sensor: Glucoclear®, Edwards) in 20 patients on a cardio-surgical ICU in a head to head comparison. CGM data were recorded for up to 48 h and values were compared with blood-gas-analysis (BGA) values, analysed with Bland-Altman-plots and color-coded surveillance error-grids. Shown are means ± standard deviations. In total 270/255 intravasal/subcutaneous pairs with BGA-values were analysed. The average runtime of the sensors was 28.4 ± 6.4 h. Correlation with BGA values yielded a correlation coefficient of 0.76 (subcutaneous sensor) and 0.92 (intravasal sensor). The Bland Altman Plots revealed an accuracy of 2.5 mg/dl, and a precision of + 43.0 mg/dl to - 38.0 mg/dl (subcutaneous sensor) and an accuracy of - 6.0 mg/dl, and a precision of + 12.4 mg/dl to - 24.4 mg/dl (intravasal sensor). No severe hypoglycemic event, defined as BG level below 40 mg/dl, occurred during treatment. Both sensors showed good accuracy in comparison to the BGA values, however they differ regarding precision, which in case of the subcutaneous sensor is considerable high.

Entities:  

Keywords:  Blood glucose; Cardio-surgical patients; Continuous glucose monitoring; Sensors

Mesh:

Substances:

Year:  2018        PMID: 30421152     DOI: 10.1007/s10877-018-0221-5

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  22 in total

Review 1.  A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output.

Authors:  Lester A Critchley; Anna Lee; Anthony M-H Ho
Journal:  Anesth Analg       Date:  2010-08-24       Impact factor: 5.108

2.  Hypoglycemia and outcome in critically ill patients.

Authors:  Moritoki Egi; Rinaldo Bellomo; Edward Stachowski; Craig J French; Graeme K Hart; Gopal Taori; Colin Hegarty; Michael Bailey
Journal:  Mayo Clin Proc       Date:  2010-02-22       Impact factor: 7.616

3.  Adoption and implementation of the original strict glycemic control guideline is feasible and safe in adult critically ill patients.

Authors:  M J Schultz; R E Harmsen; J C Korevaar; A Abu-Hanna; F Van Braam Houckgeest; J P Van Der Sluijs; P E Spronk
Journal:  Minerva Anestesiol       Date:  2012-05-25       Impact factor: 3.051

4.  Intensive versus conventional glucose control in critically ill patients.

Authors:  Simon Finfer; Dean R Chittock; Steve Yu-Shuo Su; Deborah Blair; Denise Foster; Vinay Dhingra; Rinaldo Bellomo; Deborah Cook; Peter Dodek; William R Henderson; Paul C Hébert; Stephane Heritier; Daren K Heyland; Colin McArthur; Ellen McDonald; Imogen Mitchell; John A Myburgh; Robyn Norton; Julie Potter; Bruce G Robinson; Juan J Ronco
Journal:  N Engl J Med       Date:  2009-03-24       Impact factor: 91.245

5.  Hyperglycemia: an independent marker of in-hospital mortality in patients with undiagnosed diabetes.

Authors:  Guillermo E Umpierrez; Scott D Isaacs; Niloofar Bazargan; Xiangdong You; Leonard M Thaler; Abbas E Kitabchi
Journal:  J Clin Endocrinol Metab       Date:  2002-03       Impact factor: 5.958

6.  The impact of early hypoglycemia and blood glucose variability on outcome in critical illness.

Authors:  Sean M Bagshaw; Rinaldo Bellomo; Michael J Jacka; Moritoki Egi; Graeme K Hart; Carol George
Journal:  Crit Care       Date:  2009-06-17       Impact factor: 9.097

7.  Glycemic variability and glucose complexity in critically ill patients: a retrospective analysis of continuous glucose monitoring data.

Authors:  Richard Brunner; Gabriel Adelsmayr; Harald Herkner; Christian Madl; Ulrike Holzinger
Journal:  Crit Care       Date:  2012-10-02       Impact factor: 9.097

Review 8.  Clinical review: Consensus recommendations on measurement of blood glucose and reporting glycemic control in critically ill adults.

Authors:  Simon Finfer; Jan Wernerman; Jean-Charles Preiser; Tony Cass; Thomas Desaive; Roman Hovorka; Jeffrey I Joseph; Mikhail Kosiborod; James Krinsley; Iain Mackenzie; Dieter Mesotten; Marcus J Schultz; Mitchell G Scott; Robbert Slingerland; Greet Van den Berghe; Tom Van Herpe
Journal:  Crit Care       Date:  2013-06-14       Impact factor: 9.097

9.  Continuous on-line glucose measurement by microdialysis in a central vein. A pilot study.

Authors:  Christina Blixt; Olav Rooyackers; Bengt Isaksson; Jan Wernerman
Journal:  Crit Care       Date:  2013-05-11       Impact factor: 9.097

10.  Accuracy and limitations of continuous glucose monitoring using spectroscopy in critically ill patients.

Authors:  Roosmarijn Tm van Hooijdonk; Tineke Winters; Johan C Fischer; Edmée C van Dongen-Lases; James S Krinsley; Jean-Charles Preiser; Marcus J Schultz
Journal:  Ann Intensive Care       Date:  2014-03-06       Impact factor: 6.925

View more
  1 in total

1.  Accuracy and stability of an arterial sensor for glucose monitoring in a porcine model using glucose clamp technique.

Authors:  Felix Aberer; Verena Theiler-Schwetz; Haris Ziko; Bettina Hausegger; Iris Wiederstein-Grasser; Daniel A Hochfellner; Philipp Eller; Georg Tomberger; Martin Ellmerer; Julia K Mader; Vladimir Bubalo
Journal:  Sci Rep       Date:  2020-04-20       Impact factor: 4.379

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.