Literature DB >> 22198902

Comparison of Microlife BP A200 Plus and Omron M6 blood pressure monitors to detect atrial fibrillation in hypertensive patients.

Giuseppe Marazzi1, Ferdinando Iellamo, Maurizio Volterrani, Mauro Lombardo, Francesco Pelliccia, Daniela Righi, Fabrizia Grieco, Luca Cacciotti, Luigi Iaia, Giuseppe Caminiti, Giuseppe Rosano.   

Abstract

INTRODUCTION: Self-monitoring home blood pressure (BP) devices are currently recommended for long-term follow-up of hypertension and its management. Some of these devices are integrated with algorithms aimed at detecting atrial fibrillation (AF), which is common essential hypertension. This study was designed to compare the diagnostic accuracy of two widely diffused home BP monitoring devices in detecting AF in an unselected population of outpatients referred to a hypertension clinic because of high BP.
METHODS: In 503 consecutive patients the authors simultaneously compared the accuracy of the Microlife(®) BP A200 Plus (Microlife) and the OMRON(®) M6 (OMRON) home BP devices, in detecting AF.
RESULTS: Systolic and diastolic BP as well as heart rate (HR) values detected by the two devices were not significantly different. Pulse irregularity was detected in 124 and 112 patients with the OMRON M6 and Microlife BP A200 Plus devices, respectively. Simultaneous electrocardiogram (ECG) recording revealed that pulse irregularity was due to AF in 101 patients. Pulse irregularity detected by the OMRON M6 device corresponded to AF in 101, to supraventricular premature beats in 18, and to frequent premature ventricular beat in five patients, respectively. Pulse irregularity detected by the Microlife BP A200 Plus device corresponded to AF in 93, to supraventricular premature beats in 14, and to ventricular premature beats in five patients. The sensitivity for detecting AF was 100%, the specificity was 92%, and diagnostic accuracy 95% for the OMRON M6 and 100%, 92%, and 95 for the Microlife BP A200 Plus, respectively. AF was newly diagnosed by ECG recordings in 47 patients, and was detected in all patients by the OMRON device, and in 42 patients by the Microlife device.
CONCLUSION: These results indicate that OMRON M6 is more accurate than Microlife BP A200 Plus in detecting AF in patients with essential hypertension. Widespread use of these devices in hypertensive patients could be of clinical benefit for the early diagnosis and treatment of this arrhythmia and related consequences.

Entities:  

Mesh:

Year:  2011        PMID: 22198902     DOI: 10.1007/s12325-011-0087-0

Source DB:  PubMed          Journal:  Adv Ther        ISSN: 0741-238X            Impact factor:   3.845


  17 in total

1.  Comprehensive metabolomic and proteomic analyses reveal candidate biomarkers and related metabolic networks in atrial fibrillation.

Authors:  Juntuo Zhou; Lijie Sun; Liwen Chen; Shuwang Liu; Lijun Zhong; Ming Cui
Journal:  Metabolomics       Date:  2019-06-21       Impact factor: 4.290

2.  Screening for Atrial Fibrillation During Automatic Blood Pressure Measurements.

Authors:  Andrew Lowe; Timothy H Oh; Ralph Stewart
Journal:  IEEE J Transl Eng Health Med       Date:  2018-10-09       Impact factor: 3.316

Review 3.  Silent atrial fibrillation: epidemiology, diagnosis, and clinical impact.

Authors:  Polychronis E Dilaveris; Harold L Kennedy
Journal:  Clin Cardiol       Date:  2017-03-08       Impact factor: 2.882

4.  2021 ISHNE/HRS/EHRA/APHRS Expert Collaborative Statement on mHealth in Arrhythmia Management: Digital Medical Tools for Heart Rhythm Professionals: From the International Society for Holter and Noninvasive Electrocardiology/Heart Rhythm Society/European Heart Rhythm Association/Asia-Pacific Heart Rhythm Society.

Authors:  Niraj Varma; Iwona Cygankiewicz; Mintu P Turakhia; Hein Heidbuchel; Yu-Feng Hu; Lin Yee Chen; Jean-Philippe Couderc; Edmond M Cronin; Jerry D Estep; Lars Grieten; Deirdre A Lane; Reena Mehra; Alex Page; Rod Passman; Jonathan P Piccini; Ewa Piotrowicz; Ryszard Piotrowicz; Pyotr G Platonov; Antonio Luiz Ribeiro; Robert E Rich; Andrea M Russo; David Slotwiner; Jonathan S Steinberg; Emma Svennberg
Journal:  Circ Arrhythm Electrophysiol       Date:  2021-02-12

5.  2021 ISHNE/HRS/EHRA/APHRS Collaborative Statement on mHealth in Arrhythmia Management: Digital Medical Tools for Heart Rhythm Professionals: From the International Society for Holter and Noninvasive Electrocardiology/Heart Rhythm Society/European Heart Rhythm Association/Asia Pacific Heart Rhythm Society.

Authors:  Niraj Varma; Iwona Cygankiewicz; Mintu P Turakhia; Hein Heidbuchel; Yufeng Hu; Lin Yee Chen; Jean-Philippe Couderc; Edmond M Cronin; Jerry D Estep; Lars Grieten; Deirdre A Lane; Reena Mehra; Alex Page; Rod Passman; Jonathan P Piccini; Ewa Piotrowicz; Ryszard Piotrowicz; Pyotr G Platonov; Antonio Luiz Ribeiro; Robert E Rich; Andrea M Russo; David Slotwiner; Jonathan S Steinberg; Emma Svennberg
Journal:  Cardiovasc Digit Health J       Date:  2021-01-29

6.  Atrial fibrillation screening during automated blood pressure measurement-Comment on "Diagnostic accuracy of new algorithm to detect atrial fibrillation in a home blood pressure monitor".

Authors:  Yi Chen; Lei Lei; Ji-Guang Wang
Journal:  J Clin Hypertens (Greenwich)       Date:  2017-09-24       Impact factor: 3.738

7.  Accuracy of automated blood pressure measurements in the presence of atrial fibrillation: systematic review and meta-analysis.

Authors:  Christopher E Clark; Sinead T J McDonagh; Richard J McManus
Journal:  J Hum Hypertens       Date:  2019-01-10       Impact factor: 3.012

8.  Blood Pressure in Patients With Atrial Fibrillation: Part 1--Measurement.

Authors:  Debbie L Cohen; Raymond R Townsend
Journal:  J Clin Hypertens (Greenwich)       Date:  2016-08-20       Impact factor: 3.738

9.  Incidence of New Onset Atrial Fibrillation After Cardiovascular Surgery in Vietnam: Results From A Novel Screening Strategy.

Authors:  Linh Ngo; Thinh Duc; Ba Vu Van; KienTrung Hoang; Dzung Tien Le; Huu Cong Nguyen; Thuy Tran Nguyen; Ben Freedman; Nicole Lowres
Journal:  J Atr Fibrillation       Date:  2021-08-31

10.  Opportunistic detection of atrial fibrillation using blood pressure monitors: a systematic review.

Authors:  Sarah A Kane; James R Blake; Frank J McArdle; Philip Langley; Andrew J Sims
Journal:  Open Heart       Date:  2016-04-12
View more