| Literature DB >> 30400839 |
Zhen Li1, Zhike Xu2, Yaqin Wang2, Qiang Liu2, Bin Chen2.
Abstract
BACKGROUND: The prevalence of primary iris and/or ciliary body cysts is common in myopia, though asymptomatic in nearly all cases. It's a very valuable thing to study the clinical safety and reliability of implantable collamer lens (ICL) surgery in patients with primary iris and/or ciliary body cysts.Entities:
Keywords: Implantable collamer lens; Myopia; Phakic intraocular lens; Primary iris and ciliary body cyst; Ultrasound biomicroscope
Mesh:
Year: 2018 PMID: 30400839 PMCID: PMC6218971 DOI: 10.1186/s12886-018-0935-7
Source DB: PubMed Journal: BMC Ophthalmol ISSN: 1471-2415 Impact factor: 2.209
Fig. 1Postoperative parameters of TIA and AOD500 corresponding to the cysts on the UBM image
Preoperative ocular parameters in two groups (Mean ± _ Standard Deviation)
| Parameters | Groups | |||
|---|---|---|---|---|
| Group1(Mean ± SD) | Group 2(Mean ± SD) | t |
| |
| UDVA | 0.04 ± 0.03 | 0.03 ± 0.03 | 1.460 | 0.149 |
| CDVA | 0.91 ± 0.18 | 0.78 ± 0.25 | 1.948 | 0.056 |
| Manifest refractive sphere(D) | 12.76 ± 4.00 | 13.71 ± 5.01 | −0.723 | 0.427 |
| Manifest refractive cylinder(D) | 1.78 ± 1.13 | 1.44 ± 0.92 | 1.235 | 0.221 |
| IOP | 15.33 ± 3.76 | 16.14 ± 3.13 | −0.889 | 0.377 |
| ACD | 3.25 ± 0.19 | 3.16 ± 0.24 | 1.422 | 0.160 |
| CT | 528.61 ± 37.98 | 526.06 ± 28.31 | 0.297 | 0.797 |
| ACV | 216.00 ± 30.07 | 199.90 ± 30.57 | 1.938 | 0.057 |
| AOD500 | 0.617 ± 0.222 | 0.583 ± 0.185 | 0.639 | 0.525 |
| TIA | 47.92 ± 9.79 | 47.40 ± 9.43 | 0.199 | 0.843 |
Fig. 2Preoperative vertical and horizontal scanning images of multiple cysts. a. Preoperative vertical scanning image of multiple cysts in 3’o clock in left eye. b. Preoperative horizontal scanning image of multiple cysts in 3’o clock in left eye
Comparison of the preoperative TIA and AOD500 corresponding to the cysts (Mean ± _ Standard Deviation)
| Location | ||||
|---|---|---|---|---|
| Corresponding to the cysts (Mean ± SD) | mean value of 4 clocks (Mean ± SD) | t |
| |
| AOD500 | 0.573 ± 0.202 | 0.617 ± 0.222 | 0.719 | 0.476 |
| TIA | 47.17 ± 10.75 | 47.92 ± 9.79 | 0.818 | 0.807 |
Comparing the parameters of AOD500 and TIA in 3,6,9,12’o clock
| Location Group and | TIA(°) | AOD500(mm) | |||||
|---|---|---|---|---|---|---|---|
| Pre-operation post-operation(6th month) |
| Pre-operation post-operation (6th month) |
| ||||
| 3’o clock | Group1 | 45.40 ± 8.29 | 22.67 ± 6.15 | 0.000 | 0.51 ± 0.14 | 0.21 ± 0.06 | 0.000 |
| Group2 | 47.37 ± 8.29 | 27.56 ± 8.50 | 0.000 | 0.53 ± 0.13 | 0.26 ± 0.09 | 0.000 | |
| P-value | 0.560 | 0.368 | 0.750 | 0.314 | |||
| 6’o clock | Gropu1 | 40.77 ± 12.98 | 24.11 ± 4.27 | 0.000 | 0.46 ± 0.20 | 0.21 ± 0.04 | 0.001 |
| Group2 | 52.71 ± 7.87 | 21.60 ± 2.97 | 0.013 | 0.68 ± 0.23 | 0.19 ± 0.03 | 0.009 | |
| P-value | 0.090 | 0.368 | 0.101 | 0.633 | |||
| 9’o clock | Group1 | 44.96 ± 9.00 | 26.30 ± 7.11 | 0.001 | 0.53 ± 0.19 | 0.25 ± 0.09 | 0.001 |
| Group2 | 48.03 ± 4.53 | 25.54 ± 5.72 | 0.000 | 0.56 ± 0.09 | 0.26 ± 0.06 | 0.001 | |
| P-value | 0.314 | 1.000 | 0.315 | 0.832 | |||
| 12’o clock | Group1 | 42.96 ± 9.15 | 20.84 ± 5.80 | 0.000 | 0.48 ± 0.19 | 0.19 ± 0.05 | 0.000 |
| Group2 | 45.16 ± 4.41 | 19.67 ± 4.53 | 0.000 | 0.52 ± 0.08 | 0.19 ± 0.06 | 0.002 | |
| P-value | 0.289 | 0.711 | 0.20 | 0.791 | |||
Postoperative parameters of IOP, Vault and CE-ICL for the two groups
| Parameters | Time | Groups | ||
|---|---|---|---|---|
| Group 1(Mean ± SD) | Group2(Mean ± SD) | 1P | ||
| IOP(mmHg) | 1mo | 17.11 ± 2.95 | 16.20 ± 3.25 | 0.295 |
| 3mo | 16.83 ± 2.04 | 17.27 ± 2.62 | 0.578 | |
| 6mo | 16.33 ± 2.74 | 16.71 ± 2.64 | 0.560 | |
| 12mo | 16.44 ± 1.98 | 16.78 ± 2.35 | 0.580 | |
| 2 P | P > 0.05 | |||
| Vault(mm) | 1mo | 0.62 ± 0.26 | 0.50 ± 0.27 | 0.157 |
| 3mo | 0.62 ± 0.25 | 0.52 ± 0.24 | 0.197 | |
| 6mo | 0.62 ± 0.25 | 0.51 ± 0.23 | 0.111 | |
| 12mo | 0.61 ± 0.23 | 0.51 ± 0.22 | 0.109 | |
| 2P | P > 0.05 | |||
| CE-ICL (mm) | 1mo | 2.23 ± 0.32 | 2.37 ± 0.37 | 0.132 |
| 3mo | 2.25 ± 0.27 | 2.35 ± 0.33 | 0.243 | |
| 6mo | 2.25 ± 0.26 | 2.34 ± 0.33 | 0.264 | |
| 12mo | 2.26 ± 0.24 | 2.35 ± 0.33 | 0.229 | |
| 2P | P > 0.05 | |||
Fig. 3Postoperative horizontal scanning image of multiple cysts in 3’o clock in left eye. a. The haptics of ICL would induce the broken of cyst capsule. b. The haptics of ICL in the location of cysts in ciliary sulcus, which would be likely to push the root of iris forwarding and induce the anterior chamber angle narrow or close up
Fig. 4Excessive vault is a high risk factor to induce glaucoma. In this eye, the central vault was more than 1.25 mm, and the anterior chamber angle was closed in the location of ICL haptics