| Literature DB >> 30355561 |
Yue Liao1, Susan Schembre1,2.
Abstract
BACKGROUND: Wearable sensors have been increasingly used in behavioral research for real-time assessment and intervention purposes. The rapid advancement of biomedical technology typically used in clinical settings has made wearable sensors more accessible to a wider population. Yet the acceptability of this technology for nonclinical purposes has not been examined.Entities:
Keywords: accelerometry; physiological monitoring; remote monitoring; user experience; wearable sensors
Year: 2018 PMID: 30355561 PMCID: PMC6231900 DOI: 10.2196/11181
Source DB: PubMed Journal: JMIR Mhealth Uhealth ISSN: 2291-5222 Impact factor: 4.773
Figure 1Dexcom G4 Platinum continuous glucose monitoring system.
Participant characteristics (N=30).
| Characteristic | Participants |
| Age (years), mean (SD) | 37.9 (13.2) |
| Female, n (%) | 22 (73) |
| Hispanic, n (%) | 5 (17) |
| Overweight, n (%) | 14 (47) |
| Obese, n (%) | 5 (17) |
| College graduated, n (%) | 28 (93) |
| Full-time employed, n (%) | 22 (73) |
Participant experiences of each study tool (N=30)a.
| Acceptability survey item | CGMb sensor, | CGM receiver, | MyFitnessPal, | Accelerometer, |
| Usability: this tool is easy to use and user friendly | 28 (93) | 27 (90) | 28 (93) | 28 (93) |
| Convenience: this tool is convenient for me to use in my everyday lives | 22 (73) | 19 (63) | 22 (73) | 18 (60) |
| Value: this tool is useful and beneficial | 28 (93) | 29 (97) | 28 (93) | 23 (77) |
| Relevance: this tool provides information that is of interest to me | 27 (90) | 28 (93) | 27 (90) | 13 (43) |
| Motivating: I am motivated to use this tool to track my daily behaviors | 19 (63) | 20 (67) | 24 (80) | 11 (37) |
| Tech support: there is adequate availability and quality of professional assistance throughout use of this tool | 21 (70) | 20 (67) | 21 (70) | 18 (60) |
| Confidence: I feel confident that I use this tool correctly | 29 (97) | 28 (93) | 27 (90) | 28 (93) |
| Privacy: I am concerned about my privacy when using this tool | 1 (3) | 1 (3) | 4 (13) | 1 (3) |
| Recommend: I would recommend this tool to my friends and family | 19 (63) | 20 (67) | 28 (93) | 14 (47) |
| Like: I like using this tool | 20 (67) | 23 (77) | 24 (80) | 17 (57) |
aValues are number of participants who agreed or strongly agreed with the statement.
bContinuous glucose monitor.
Mean of acceptability score for each data collection tool and comparisons of their mean scoresa.
| Data collection tool | Acceptability score, mean (SD) | Tool, absolute mean difference (SD) | ||
| CGMb sensor | CGM receiver | MyFitnessPal | ||
| CGM sensor | 4.06 (0.55) | — | 0.01 (0.21) | 0.04 (0.90) |
| CGM receiver | 4.05 (0.58) | 0.01 (0.21) | — | 0.05 (0.90) |
| MyFitnessPal | 4.10 (0.68) | 0.04 (0.90) | 0.05 (0.90) | — |
| Accelerometer | 3.73 (0.76) | 0.33 (0.55)c | 0.32 (0.55)c | 0.37 (0.98)c |
aThe Likert scale used in the ratings was 1=strongly disagree, 2=disagree, 3=neither agree nor disagree, 4=agree, 5=strongly agree.
bContinuous glucose monitor.
cP<.05 based on a two-tailed paired-sample t test.