Literature DB >> 27358813

Assessment of the anterior loop of the mandibular canal: A study using cone-beam computed tomography.

Eduarda Helena Leandro do Nascimento1, Maria Luiza Dos Anjos Pontual2, Andréa Dos Anjos Pontual2, Danyel Elias da Cruz Perez2, José Natal Figueiroa3, Marco Antônio Gomes Frazão4, Flávia Maria de Moraes Ramos-Perez2.   

Abstract

PURPOSE: Sufficient area in the interforaminal region is required for dental implant placement, and the anterior loop of the mandibular canal is located within the limits of this area. The aim of this study was to evaluate the prevalence and extent of the anterior loop in a Brazilian sample population using cone-beam computed tomography (CBCT).
MATERIALS AND METHODS: CBCT images from 250 patients (500 hemimandibles) obtained for various clinical indications were randomly selected and evaluated to determine the presence and length of the anterior loop. The length of the anterior loop was then compared based on gender, age, and the side of the mandible. The data were analyzed using the Pearson chi-square test and linear regression analysis.
RESULTS: An anterior loop was identified in 41.6% of the cases, and its length ranged from 0.25 mm to 4.00 mm (mean, 1.1±0.8 mm). The loop had a greater mean length and was significantly more prevalent in males (p=0.014). No significant differences were found between the right and left sides regarding length (p=0.696) or prevalence (p=0.650).
CONCLUSION: In this study, a high prevalence of the anterior loop of the mandibular canal was found, and although its length varied greatly, in most cases it was less than 1 mm long. Although this is a prevalent anatomical variation, safety limits for the placement of implants in this region cannot be established before an accurate evaluation using imaging techniques in order to identify and preserve the neurovascular bundles.

Entities:  

Keywords:  Anatomic Variation; Cone-Beam Computed Tomography; Mandible

Year:  2016        PMID: 27358813      PMCID: PMC4925653          DOI: 10.5624/isd.2016.46.2.69

Source DB:  PubMed          Journal:  Imaging Sci Dent        ISSN: 2233-7822


  16 in total

Review 1.  The mental foramen and nerve: clinical and anatomical factors related to dental implant placement: a literature review.

Authors:  Gary Greenstein; Dennis Tarnow
Journal:  J Periodontol       Date:  2006-12       Impact factor: 6.993

2.  Measurement of anterior loop length for the mandibular canal and diameter of the mandibular incisive canal to avoid nerve damage when installing endosseous implants in the interforaminal region: a second attempt introducing cone beam computed tomography.

Authors:  Yuki Uchida; Nobuhiro Noguchi; Masaaki Goto; Yoshio Yamashita; Tsunehiko Hanihara; Hitoshi Takamori; Iwao Sato; Taisuke Kawai; Takashi Yosue
Journal:  J Oral Maxillofac Surg       Date:  2009-04       Impact factor: 1.895

3.  A radiographic study on the visualization of the anterior loop in dentate subjects of different age groups.

Authors:  Wei Cheong Ngeow; Dionetta D Dionysius; Hayati Ishak; Phrabhakaran Nambiar
Journal:  J Oral Sci       Date:  2009-06       Impact factor: 1.556

4.  Dosimetry and image quality of four dental cone beam computed tomography scanners compared with multislice computed tomography scanners.

Authors:  A Suomalainen; T Kiljunen; Y Käser; J Peltola; M Kortesniemi
Journal:  Dentomaxillofac Radiol       Date:  2009-09       Impact factor: 2.419

5.  Assessment of variations of the mandibular canal through cone beam computed tomography.

Authors:  Christiano de Oliveira-Santos; Paulo Henrique Couto Souza; Soraya de Azambuja Berti-Couto; Lien Stinkens; Kristin Moyaert; Izabel Regina Fischer Rubira-Bullen; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2011-03-30       Impact factor: 3.573

6.  Retrospective study of the anterior loop of the inferior alveolar nerve and the incisive canal using cone beam computed tomography.

Authors:  Marcio Borges Rosa; Bruno Salles Sotto-Maior; Vinicius de Carvalho Machado; Carlos Eduardo Francischone
Journal:  Int J Oral Maxillofac Implants       Date:  2013 Mar-Apr       Impact factor: 2.804

7.  The inferior alveolar nerve's loop at the mental foramen and its implications for surgery.

Authors:  Katharina Filo; Thomas Schneider; Michael C Locher; Astrid L Kruse; Heinz-Theo Lübbers
Journal:  J Am Dent Assoc       Date:  2014-03       Impact factor: 3.634

8.  The anterior loop of the inferior alveolar nerve: prevalence, measurement of its length and a recommendation for interforaminal implant installation based on cone beam CT imaging.

Authors:  Dimitrios Apostolakis; Jackie E Brown
Journal:  Clin Oral Implants Res       Date:  2011-08-03       Impact factor: 5.977

9.  Anterior loop of the mental nerve: a morphological and radiographic study.

Authors:  Dusan V Kuzmanovic; Alan G T Payne; Jules A Kieser; George J Dias
Journal:  Clin Oral Implants Res       Date:  2003-08       Impact factor: 5.977

10.  Morphometric analysis of implant-related anatomy in Caucasian skulls.

Authors:  Rodrigo F Neiva; Ricardo Gapski; Hom-Lay Wang
Journal:  J Periodontol       Date:  2004-08       Impact factor: 6.993

View more
  14 in total

1.  Location of the course of the mandibular canal, anterior loop and accessory mental foramen through cone-beam computed tomography.

Authors:  Clarissa Lopes Vieira; Suzanni do Amaral Rodrigues Veloso; Fernanda Ferreira Lopes
Journal:  Surg Radiol Anat       Date:  2018-08-17       Impact factor: 1.246

2.  Analysis of the frequency of visualization of morphological variations in anatomical bone features in the mandibular interforaminal region through cone-beam computed tomography.

Authors:  Marilza do Carmo Oliveira; Tamara Kerber Tedesco; Thais Gimenez; Sergio Allegrini
Journal:  Surg Radiol Anat       Date:  2018-05-21       Impact factor: 1.246

3.  Assessment of Implant-Related Anatomical Landmarks in the Mandibular Interforaminal Region in an Iranian Population Using Cone-Beam Computed Tomography.

Authors:  Nafiseh Nikkerdar; Amin Golshah; Razieh Mahmoodivesali; Sepideh Falah-Kooshki
Journal:  Contemp Clin Dent       Date:  2022-06-21

Review 4.  Prevalence and extension of the anterior loop of the mental nerve in different populations and CBCT imaging settings: A systematic review and meta-analysis.

Authors:  Mahdi Hadilou; Leila Gholami; Morteza Ghojazadeh; Naghmeh Emadi
Journal:  Imaging Sci Dent       Date:  2022-04-28

5.  Morphometric Analysis of the Mental Foramen Using Cone-Beam Computed Tomography.

Authors:  Rudyard Dos Santos Oliveira; Maria Rodrigues Coutinho; Francine Kühl Panzarella
Journal:  Int J Dent       Date:  2018-03-26

6.  Assessment of the Anterior Loop of the Mandibular Canal Using Cone-Beam Computed Tomography in Eastern India: A Record-Based Study.

Authors:  Smriti Sinha; Srinivas Kandula; N C Sangamesh; Purnendu Rout; Silpiranjan Mishra; Atul Anand Bajoria
Journal:  J Int Soc Prev Community Dent       Date:  2019-06-07

7.  Momentousness of the Mental Loop: A Comparative Study.

Authors:  Ramya Katyayani Kastala; Chaya Manoranjini David; Namitha Jayapal
Journal:  Contemp Clin Dent       Date:  2019 Jan-Mar

8.  Positioning errors of dental implants and their associations with adjacent structures and anatomical variations: A CBCT-based study.

Authors:  Beatriz Ribeiro Ribas; Eduarda Helena Leandro Nascimento; Deborah Queiroz Freitas; Andréa Dos Anjos Pontual; Maria Luiza Dos Anjos Pontual; Danyel Elias Cruz Perez; Flávia Maria Moraes Ramos-Perez
Journal:  Imaging Sci Dent       Date:  2020-12-15

9.  Novel Use of Orbita Plates in Mandibular Body Fractures.

Authors:  Sonal Anchlia; Jigar M Dhuvad; Dhruvi Shukla; Rohit Kumar; Nisarg Patel; Vipul Nagavadiya
Journal:  J Maxillofac Oral Surg       Date:  2018-02-17

10.  Association between the Anatomy of the Mandibular Canal and Facial Types: A Cone-Beam Computed Tomography Analysis.

Authors:  Rudyard Dos Santos Oliveira; Arlete Maria Gomes Oliveira; José Luiz Cintra Junqueira; Francine Kühl Panzarella
Journal:  Int J Dent       Date:  2018-09-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.