| Literature DB >> 30335818 |
Camilla Rodrigues de Souza Silva1, André Dos Santos Costa2, Taciano Rocha3, Diogo Arruda Martins de Lima4, Tamires do Nascimento4, Sílvia Regina Arruda de Moraes5.
Abstract
Muscle architecture parameters performed using ultrasound serve as an aid to monitor muscle changes derived from diseases, however there are no studies that determine the reliability and applicability of this evaluation in individuals with type 2 diabetes (DM2). Three raters captured three images of measurements of thickness of the rectus femoris (RF), vastus intermedius and anterior quadriceps, RF muscle cross-sectional area, RF pennation angle in 17 individuals with DM2 above 50 and sedentary. Intra and inter-raters analysis showed reliability from high to very high for the three raters (ICC> 0.87), except for the RF pennation angle with moderate to low intra-raters (ICC = 0.58, 0.48, 0.51), and high inter-rater reliability (ICC = 0.70). Ultrasound measurements of quadriceps muscles showed high to very high intra and inter-raters reliability, thus allowing its use to monitor muscle changes provoked by diabetes or interventions in individuals with DM2.Entities:
Mesh:
Year: 2018 PMID: 30335818 PMCID: PMC6193658 DOI: 10.1371/journal.pone.0205724
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Fig 1Thickness measurements.
Measurements of thickness of rectus, thickness of vastus intermedius and thickness of anterior quadríceps.
Fig 2Rectus femoris muscle cross-sectional area.
Measurement of rectus femoris muscle cross-sectional area.
Fig 3Pennation angle of the rectus femoris muscle.
Measurement of rectus femoris pennation angle.
Descriptive values of intra and inter-rater reliability analysis.
| Mean ± SD | ICC (95%IC) | SEM | CV (%) | MDD | ||
|---|---|---|---|---|---|---|
| R1 | 12,12 ± 2,56 | 0,96 (0,91 a 0,98) | 1,48 | 3,35 | ||
| R2 | 13,30 ± 2,76 | 0,97 (0,93 a 0,98) | 1,37 | 3,0 | ||
| R3 | 12,75 ± 2,57 | 0,95 (0,90 a 0,98) | 1,65 | 3,82 | ||
| Inter | 12,74 ± 2,49 | 0,93 (0,85 a 0,97) | 1,98 | 6,70 | 5,48 | |
| R1 | 12,61 ± 3,22 | 0,99 (0,98 a 0,99) | 0,86 | 2,07 | ||
| R2 | 12,33 ± 2,66 | 0,98 (0,95 a 0,99) | 1,14 | 2,66 | ||
| R3 | 12,29 ± 2,97 | 0,97 (0,95 a 0,99) | 1,27 | 2,77 | ||
| Inter | 12,39 ± 2,76 | 0,92 (0,84 a 0,97) | 2,24 | 7,66 | 6,21 | |
| R1 | 26,06 ± 4,93 | 0,98 (0,96 a 0,99) | 1,81 | 1,70 | ||
| R2 | 27,13 ± 4,02 | 0,97 (0,95 a 0,99) | 1,77 | 1,80 | ||
| R3 | 26,25 ± 4,56 | 0,87 (0,74 a 0,94) | 4,50 | 3,21 | ||
| Inter | 26,43 ± 4,28 | 0,93 (0,85 a 0,97) | 3,30 | 6,18 | 9,14 | |
| R1 | 4,37 ± 1,52 | 0,96 (0,93 a 0,98) | 0,81 | 4,80 | ||
| R2 | 4,50 ± 1,68 | 0,96 (0,93 a 0,98) | 0,88 | 5,46 | ||
| R3 | 4,73 ± 1,58 | 0,98 (0,96 a 0,99) | 0,47 | 3,36 | ||
| Inter | 4,53 ± 1,50 | 0,94 (0,87 a 0,98) | 1,07 | 12,16 | 2,97 | |
| R1 | 8,57 ± 1,99 | 0,58 (0,30 a 0,80) | 3,86 | 15,97 | ||
| R2 | 11,92 ± 5,52 | 0,48 (0,20 a 0,74) | 5,41 | 18,44 | ||
| R3 | 8,88 ± 2,38 | 0,51 (0,22 a 0,76) | 5,07 | 21,68 | ||
| Inter | 8,76 ± 1,78 | 0,70 (0,32 a 0,88) | 2,93 | 15,82 | 8,12 |
RF = rectus femoris; VI = vastus intermedius; R1 = rater 1; R2 = rater 2; R3 = rater 3; SD = standard deviation; ICC = intra-class correlation coefficient; IC = confidence interval; SEM = standard error of measurement; CV = coefficient of variation; MDD = minimal detectable difference.