Literature DB >> 30319910

Visual acuity of pseudophakic patients predicted from in-vitro measurements of intraocular lenses with different design.

Fidel Vega1, Maria S Millán1, Nuria Garzón2, Irene Altemir3,4, Francisco Poyales2, Jose Manuel Larrosa4.   

Abstract

The optical quality of a set of IOLs (modeling set: one monofocal and two bifocals) was assessed through focus by the area under the modulation transfer function (MTFa) metric and related to the visual acuity (VA) defocus curves of pseudophakic patients implanted with said IOLs. A non-linear relationship between the MTFa and clinical VA was obtained with an asymptotic limit found to be the best VA achievable by the patients. Two mathematical fitting functions between clinical VA and MTFa were derived with high correlation coefficients (R2≥0.85). They were applied to the MTFa obtained from a different set of IOLs with advanced designs (trial set: one extended range of vision -ERV-, one trifocal ERV and one trifocal apodized) to predict VA versus defocus of patients implanted with these IOLs. Differences between the calculated VA and the clinical VA for both fitting models were within the standard deviation of the clinical measurements in the range of -3.00 D to 0.00 D defocus, thus proving the suitability of the MTFa metric to predict clinical VA performance of new IOL designs.

Entities:  

Keywords:  (050.1965) Diffractive lenses; (170.4460) Ophthalmic optics and devices; (170.4470) Ophthalmology; (330.1070) Vision - acuity; (330.7326) Visual optics, modeling; (330.7335) Visual optics, refractive surgery

Year:  2018        PMID: 30319910      PMCID: PMC6179423          DOI: 10.1364/BOE.9.004893

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  26 in total

1.  Optical aberrations of the human cornea as a function of age.

Authors:  A Guirao; M Redondo; P Artal
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2000-10       Impact factor: 2.129

2.  Theoretical performance of intraocular lenses correcting both spherical and chromatic aberration.

Authors:  Henk A Weeber; Patricia A Piers
Journal:  J Refract Surg       Date:  2011-11-10       Impact factor: 3.573

3.  Spherical lens versus aspheric artificial cornea for intraocular lens testing.

Authors:  Fidel Vega; María S Millán; Benjamin Wells
Journal:  Opt Lett       Date:  2010-05-15       Impact factor: 3.776

4.  Correlation between optics quality of multifocal intraocular lenses and visual acuity: tolerance to modulation transfer function decay.

Authors:  Adelina Felipe; Francisco Pastor; José M Artigas; Amparo Diez-Ajenjo; Andrés Gené; José L Menezo
Journal:  J Cataract Refract Surg       Date:  2010-04       Impact factor: 3.351

5.  Correlating optical bench performance with clinical defocus curves in varifocal and trifocal intraocular lenses.

Authors:  Ana B Plaza-Puche; Jorge L Alió; Scott MacRae; Len Zheleznyak; Esperanza Sala; Geunyoung Yoon
Journal:  J Refract Surg       Date:  2015-05       Impact factor: 3.573

6.  Halo and Through-Focus Performance of Four Diffractive Multifocal Intraocular Lenses.

Authors:  Fidel Vega; Francisco Alba-Bueno; María S Millán; Consuelo Varón; Miguel A Gil; Jose A Buil
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-06       Impact factor: 4.799

7.  Clinically Relevant Interpretations of Optical Bench Measurement of Intraocular Lenses.

Authors:  Patricia A Piers; Daniel H Chang; Aixa Alarcón; Carmen Cánovas
Journal:  J Refract Surg       Date:  2017-01-01       Impact factor: 3.573

8.  Exploring the optimum step size for defocus curves.

Authors:  James S Wolffsohn; Amit N Jinabhai; Alec Kingsnorth; Amy L Sheppard; Shehzad A Naroo; Sunil Shah; Phillip Buckhurst; Lee A Hall; Graeme Young
Journal:  J Cataract Refract Surg       Date:  2013-06       Impact factor: 3.351

9.  Objective evaluation of through-focus optical performance of presbyopia-correcting intraocular lenses using an optical bench system.

Authors:  Myoung Joon Kim; Len Zheleznyak; Scott Macrae; Hungwon Tchah; Geunyoung Yoon
Journal:  J Cataract Refract Surg       Date:  2011-07       Impact factor: 3.351

10.  Phenomenological model for interpreting the clinical significance of the in vitro optical transfer function.

Authors:  A J Lang; V Lakshminarayanan; V Portney
Journal:  J Opt Soc Am A       Date:  1993-07       Impact factor: 2.129

View more
  3 in total

1.  Model of the light sword intraocular lens: in-vitro comparative studies.

Authors:  Krzysztof Petelczyc; Andrzej Kolodziejczyk; Narcyz Błocki; Anna Byszewska; Zbigniew Jaroszewicz; Karol Kakarenko; Katarzyna Kołacz; Michał Miler; Alejandro Mira-Agudelo; Walter Torres-Sepúlveda; Marek Rękas
Journal:  Biomed Opt Express       Date:  2019-12-04       Impact factor: 3.732

2.  The Efficacy and Safety of YAG Laser Vitreolysis for Symptomatic Vitreous Floaters of Complete PVD or Non-PVD.

Authors:  Tiezhu Lin; Tongtong Li; Xinmei Zhang; Yannian Hui; Salissou Moutari; Emmanuel Eric Pazo; Guangzheng Dai; Lijun Shen
Journal:  Ophthalmol Ther       Date:  2021-11-15

3.  Through-Focus Energy Efficiency and Longitudinal Chromatic Aberration of Three Presbyopia-Correcting Intraocular Lenses.

Authors:  María S Millán; Fidel Vega
Journal:  Transl Vis Sci Technol       Date:  2020-11-09       Impact factor: 3.283

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.