| Literature DB >> 30278057 |
Siqing Yu1, Beatrice E Frueh1, Dagmar Steinmair1, Andreas Ebneter1, Sebastian Wolf1, Martin S Zinkernagel1, Marion R Munk1.
Abstract
PURPOSE: To analyze retinal blood flow before and after cataract surgery using swept-source optical coherence tomography angiography (SS-OCTA).Entities:
Mesh:
Year: 2018 PMID: 30278057 PMCID: PMC6168135 DOI: 10.1371/journal.pone.0204501
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Comparison of characteristics in the included and the excluded patients.
| Parameters | Included | Excluded | P value |
|---|---|---|---|
| Eyes (patients), n | 13 (12) | 10 (10) | - |
| Age | 71.2 ± 10.7 | 78.4 ± 8.76 | .097 |
| Male patients, n (%) | 6 (50.0) | 5 (50.0) | 1.00 |
| Right eyes, n (%) | 6 (46.2) | 6 (60.0) | .407 |
| Pre-operative BCVA | .500 ± .148 | .312 ± .211 | .024 |
| Signal strength score | 6.85 ± .555 | 5.30 ± 1.25 | .001 |
| LOCS-N, median (range) | 4 (3–6) | 4 (4–6) | .030 |
| LOCS-C, median (range) | 3 (3–5) | 4 (3–4) | .011 |
| LOCS-P, median (range) | 4 (3–5) | 4 (3–5) | .956 |
BCVA = best-corrected visual acuity; LOCS = Lens Opacities Classification system; N = nuclear; C = cortical; P = posterior subcapsular.
Numeric data are presented as means ± standard deviations where applicable.
*P < .05.
† LOCS-P scales were recorded in 4 included eyes and 5 excluded eyes.
Comparison of pre- and post-operative characteristics in the included eyes.
| Parameters | Pre-operative | Post-operative | P value |
|---|---|---|---|
| BCVA | .500 ± .148 | .800 ± .230 | .004 |
| Signal strength score | 6.85 ± .555 | 7.54 ± .660 | .013 |
BCVA = best-corrected visual acuity.
Numeric data are presented as means ± standard deviations where applicable.
*P < .05.
Comparison of pre- and post-operative microvasculature parameters.
| Layer | Location | Pre-operative | Post-operative | P value |
|---|---|---|---|---|
| SCP | Inner ring | .391 ± .032 | .424 ± .020 | .004 |
| Inner 3mm | .374 ± .031 | .405 ± .018 | .003 | |
| 3 × 3 mm | .380 ± .031 | .410 ± .021 | .004 | |
| DCP | Inner ring | .197 ± .060 | .267 ± .061 | .001 |
| Inner 3mm | .176 ± .052 | .239 ± .055 | .001 | |
| 3 × 3 mm | .187 ± .051 | .250 ± .051 | .002 | |
| SCP | Inner ring | 18.9 ± 1.49 | 20.1 ± 1.75 | .047 |
| Inner 3mm | 18.0 ± 1.37 | 19.2 ± 1.66 | .035 | |
| 3 × 3 mm | 18.1 ± 1.32 | 19.2 ± 1.67 | .053 | |
| DCP | Inner ring | 9.55 ± 3.32 | 12.7 ± 2.74 | .004 |
| Inner 3mm | 8.53 ± 2.87 | 11.3 ± 2.44 | .003 | |
| 3 × 3 mm | 9.12 ± 2.92 | 12.0 ± 2.59 | .008 | |
SCP = superficial capillary plexus; DCP = deep capillary plexus; ETDRS = Early Treatment Diabetic Retinopathy Study
Data are presented as means ± standard deviations. Perfusion and vessel density were analyzed in the inner 3 mm ETDRS ring (inner ring), the central 1 mm plus the 3 mm ETDRS ring (inner 3 mm) and the whole 3 mm × 3 mm scan area (3 × 3 mm).
*P < .05.
Fovea avascular zone measurements on SCP.
| Parameter | Pre-operative | Post-operative | P value |
|---|---|---|---|
| Area (mm2) | .231 ± .082 | .215 ± .097 | .441 |
| Perimeter (mm) | 2.31 ± .781 | 1.94 ± .443 | .061 |
| Circularity index | .589 ± .168 | .678 ± .086 | .171 |
Data are presented as means ± standard deviations. FAZ measurements were not available in 2 eyes, thus the analysis was carried out in 11 eyes.
Cohen's kappa value for inter-reader agreement of independent image grading.
| Parameters | Kappa value | P value |
|---|---|---|
| Motion artefacts | .583 | < .001 |
| Image artefacts | .313 | .006 |
| Distinguishability of FAZ | .628 | < .001 |
| Continuity of small vessels | .414 | .002 |
| Continuity of large vessels | .513 | < .001 |
FAZ = fovea avascular zone.
*P < .05.
Quantitative and qualitative evaluation of vessel continuity, vessel visibility and presence of artefacts in the SS-OCTA images.
| Layer | Parameters | Pre-operative | Post-operative | P value |
|---|---|---|---|---|
| SCP | Motion artefacts | -54 | 8 | .061 |
| N of motion artefacts | 4.77 ± 2.09 | 3.00 ± 2.94 | .089 | |
| Image artefacts | 23 | 85 | .077 | |
| Distinguishability of FAZ | -23 | 77 | < .001 | |
| Continuity of small vessels | -38 | 33 | .028 | |
| Continuity of large vessels | -46 | 62 | .003 | |
| N of bifurcations | .923 ± .760 | 1.62 ± .290 | .082 | |
| DCP | Motion artefacts | -31 | 23 | .133 |
| N of motion artefacts | 3.15 ± 1.86 | 1.84 ± 1.91 | .080 | |
| Image artefacts | 23 | 85 | .077 | |
| Distinguishability of FAZ | -62 | -8 | .026 | |
| Continuity of small vessels | -77 | 23 | .003 |
FAZ = fovea avascular zone; SCP = superficial capillary plexus; DCP = deep capillary plexus; N = number.
The consensus grading contained an individual score for each feature of each image. Individual scores ranged from -1/0/+1, and were then summed up and normalized to a final score as presented in the Table. The maximal and minimal possible final scores ranged from -100 to +100. P-values were calculated by Pearson’s χ2 test. Number of motion artifacts and bifurcations were also analyzed and presented as means ± standard deviations in the Table. P-values were calculated by Student’s t-test.
*P < .05.
† Continuity of large vessels and number of bifurcations were only graded in SCP images.
Fig 1Representative example of pre and post cataract surgery outlining the improved vessel continuity and visibility and the reduction in artefacts after cataract surgery.
A 79-year-old male cataract patient. In the DCP (A-F), 4 motion artefacts (black arrow) and one projection artefact (white arrow head) were found prior surgery (A). Perfusion density (B) and vessel density (C) were quantitatively measured. After surgery, same amount of artefacts were detected in the en-face image (D). Perfusion density (E) and vessel density (F) apparently increased. Scores of FAZ distinguishability and vessel continuity improved as well. In the SCP (G-L), 2 motion artefacts and one projection artefact were noticed before surgery (G). Severe motion artefacts disrupting the vessel continuity of the larger vessels. Perfusion density (H) and vessel density (I) were higher than in the DCP. After the surgery, 3 mild motion artefacts and no projection artefact were noticed (J). Perfusion density (K) and vessel density (L) apparently increased. FAZ was very well-defined. Scoring results (number of artefacts) are presented in the Table 6.