Literature DB >> 30267716

Evaluating changes of blood flow in retina, choroid, and outer choroid in rats in response to elevated intraocular pressure by 1300 nm swept-source OCT.

Jingjiang Xu1, Yuandong Li1, Shaozhen Song1, William Cepurna2, John Morrison2, Ruikang K Wang3.   

Abstract

We report the development of a 1300 nm swept-source optical coherence tomography (SS-OCT) system specifically designed to perform OCT imaging and optical microangiography (OMAG) in rat eyes in vivo and its use in evaluating the effects of intraocular pressure (IOP) elevation on ocular circulation. The swept laser is operated in single longitude mode with a 90 nm bandwidth centered at 1300 nm and 200 kHz A-line rate, providing remarkable sensitivity fall-off performance along the imaging depth, a larger field of view of 2.5 × 2.5 mm2 (approximately 35°), and more time-efficient imaging acquisition. The advantage of the SS-OCT/OMAG is highlighted by an increased imaging depth of the entire posterior thickness of optic nerve head (ONH) and its surrounding vascular anatomy, to include, for the first time in vivo, the vasculature at the scleral opening, allowing visualization of the circle of Zinn-Haller and posterior ciliary arteries (PCAs). Furthermore, the capillary-level resolution angiograms achieved at the retinal and choroidal layers over a larger field of view enable a significantly improved quantification of the response of vascular area density (VAD) to elevated IOP. The results indicate that reduction in perfusion of the choroid in response to elevated IOP is delayed compared to that seen in the retina; while choroidal VAD doesn't reach 50% of baseline until ~70 mmHg, the same effect is seen for the retinal VAD at ~60 mmHg. The superior image quality offered by SS-OCT may allow more comprehensive investigation of IOP-related ocular perfusion changes and their pathological roles in glaucomatous optic nerve damage.
Copyright © 2018 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Circle of Zinn-Haller; Glaucoma; Intraocular pressure; Ocular perfusion; Optic nerve head; Optical coherence tomography; Optical microangiography; Swept source OCT

Mesh:

Year:  2018        PMID: 30267716      PMCID: PMC6286199          DOI: 10.1016/j.mvr.2018.09.003

Source DB:  PubMed          Journal:  Microvasc Res        ISSN: 0026-2862            Impact factor:   3.514


  43 in total

1.  Multi-megahertz OCT: High quality 3D imaging at 20 million A-scans and 4.5 GVoxels per second.

Authors:  Wolfgang Wieser; Benjamin R Biedermann; Thomas Klein; Christoph M Eigenwillig; Robert Huber
Journal:  Opt Express       Date:  2010-07-05       Impact factor: 3.894

2.  Three dimensional optical angiography.

Authors:  Ruikang K Wang; Steven L Jacques; Zhenhe Ma; Sawan Hurst; Stephen R Hanson; Andras Gruber
Journal:  Opt Express       Date:  2007-04-02       Impact factor: 3.894

3.  Line-field parallel swept source MHz OCT for structural and functional retinal imaging.

Authors:  Daniel J Fechtig; Branislav Grajciar; Tilman Schmoll; Cedric Blatter; Rene M Werkmeister; Wolfgang Drexler; Rainer A Leitgeb
Journal:  Biomed Opt Express       Date:  2015-02-04       Impact factor: 3.732

4.  Long-range and wide field of view optical coherence tomography for in vivo 3D imaging of large volume object based on akinetic programmable swept source.

Authors:  Shaozhen Song; Jingjiang Xu; Ruikang K Wang
Journal:  Biomed Opt Express       Date:  2016-10-27       Impact factor: 3.732

5.  Akinetic all-semiconductor programmable swept-source at 1550 nm and 1310 nm with centimeters coherence length.

Authors:  M Bonesi; M P Minneman; J Ensher; B Zabihian; H Sattmann; P Boschert; E Hoover; R A Leitgeb; M Crawford; W Drexler
Journal:  Opt Express       Date:  2014-02-10       Impact factor: 3.894

6.  102-nm, 44.5-MHz inertial-free swept source by mode-locked fiber laser and time stretch technique for optical coherence tomography.

Authors:  Jiqiang Kang; Pingping Feng; Xiaoming Wei; Edmund Y Lam; Kevin K Tsia; Kenneth K Y Wong
Journal:  Opt Express       Date:  2018-02-19       Impact factor: 3.894

7.  Ultrahigh sensitive optical microangiography for in vivo imaging of microcirculations within human skin tissue beds.

Authors:  Lin An; Jia Qin; Ruikang K Wang
Journal:  Opt Express       Date:  2010-04-12       Impact factor: 3.894

8.  Optical Microangiography: A Label Free 3D Imaging Technology to Visualize and Quantify Blood Circulations within Tissue Beds in vivo.

Authors:  Ruikang K Wang
Journal:  IEEE J Sel Top Quantum Electron       Date:  2010-05       Impact factor: 4.544

Review 9.  Optical coherence tomography angiography: A comprehensive review of current methods and clinical applications.

Authors:  Amir H Kashani; Chieh-Li Chen; Jin K Gahm; Fang Zheng; Grace M Richter; Philip J Rosenfeld; Yonggang Shi; Ruikang K Wang
Journal:  Prog Retin Eye Res       Date:  2017-07-29       Impact factor: 21.198

10.  Ultrahigh speed endoscopic optical coherence tomography using micromotor imaging catheter and VCSEL technology.

Authors:  Tsung-Han Tsai; Benjamin Potsaid; Yuankai K Tao; Vijaysekhar Jayaraman; James Jiang; Peter J S Heim; Martin F Kraus; Chao Zhou; Joachim Hornegger; Hiroshi Mashimo; Alex E Cable; James G Fujimoto
Journal:  Biomed Opt Express       Date:  2013-06-14       Impact factor: 3.732

View more
  6 in total

1.  Ocular Perfusion Pressure in 7- and 12-Year-Old Chinese Children: The Anyang Childhood Eye Study.

Authors:  Wei-Ling Bai; Yu-Ting Kang; Shi-Ming Li; Jia-He Gan; Shi-Fei Wei; Meng-Tian Kang; Yun-Yun Sun; Ming-Hao Sun; He Li; Feng-Ju Zhang; Ning-Li Wang
Journal:  Transl Vis Sci Technol       Date:  2022-10-03       Impact factor: 3.048

2.  Retrobulbar blood flow in rat eyes during acute elevation of intraocular pressure.

Authors:  Ronald H Silverman; Raksha Urs; Gulgun Tezel; Xiangjun Yang; Inez Nelson; Jeffrey A Ketterling
Journal:  Exp Eye Res       Date:  2021-04-28       Impact factor: 3.770

3.  Choroidal vascular index in patients with open angle glaucoma and preperimetric glaucoma.

Authors:  Yuli Park; Kyong Jin Cho
Journal:  PLoS One       Date:  2019-03-20       Impact factor: 3.240

4.  Relationship between retinal capillary vessel density of OCT angiography and intraocular pressure in pig.

Authors:  Mihyun Choi; Seong-Woo Kim; Somin Ahn; Thi Que Anh Vu; Cheolmin Yun; Yong Yeon Kim
Journal:  Sci Rep       Date:  2021-04-20       Impact factor: 4.379

5.  Analysis of Microvasculature in Nonhuman Primate Macula With Acute Elevated Intraocular Pressure Using Optical Coherence Tomography Angiography.

Authors:  Mihyun Choi; Seong-Woo Kim; Thi Que Anh Vu; Young-Jin Kim; Hachul Jung; Donggwan Shin; Heejong Eom; Young Ho Kim; Cheolmin Yun; Yong Yeon Kim
Journal:  Invest Ophthalmol Vis Sci       Date:  2021-12-01       Impact factor: 4.799

6.  LIF, a mitogen for choroidal endothelial cells, protects the choriocapillaris: implications for prevention of geographic atrophy.

Authors:  Pin Li; Qin Li; Nilima Biswas; Hong Xin; Tanja Diemer; Lixian Liu; Lorena Perez Gutierrez; Giovanni Paternostro; Carlo Piermarocchi; Sergii Domanskyi; Ruikang K Wang; Napoleone Ferrara
Journal:  EMBO Mol Med       Date:  2021-11-15       Impact factor: 12.137

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.