Literature DB >> 29475287

102-nm, 44.5-MHz inertial-free swept source by mode-locked fiber laser and time stretch technique for optical coherence tomography.

Jiqiang Kang, Pingping Feng, Xiaoming Wei, Edmund Y Lam, Kevin K Tsia, Kenneth K Y Wong.   

Abstract

A swept source with both high repetition-rate and broad bandwidth is indispensable to enable optical coherence tomography (OCT) with high imaging rate and high axial resolution. However, available swept sources are commonly either limited in speed (sub-MHz) by inertial or kinetic component, or limited in bandwidth (<100 nm) by the gain medium. Here we report an ultrafast broadband (over 100 nm centered at 1.55-µm) all-fiber inertial-free swept source built upon a high-power dispersion-managed fiber laser in conjunction with an optical time-stretch module which bypasses complex optical amplification scheme, which result in a portable and compact implementation of time-stretch OCT (TS-OCT) at A-scan rate of 44.5-MHz, axial resolution of 14 µm in air (or 10 µm in tissue), and flat sensitivity roll-off within 4.3 mm imaging range. Together with the demonstration of two- and three-dimensional OCT imaging of a mud-fish eye anterior segment, we also perform comprehensive studies on the imaging depth, receiver bandwidth, and group velocity dispersion condition. This all-fiber inertia-free swept source could provide a promising source solution for SS-OCT system to realize high-performance volumetric OCT imaging in real time.

Year:  2018        PMID: 29475287     DOI: 10.1364/OE.26.004370

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  5 in total

1.  Evaluating changes of blood flow in retina, choroid, and outer choroid in rats in response to elevated intraocular pressure by 1300 nm swept-source OCT.

Authors:  Jingjiang Xu; Yuandong Li; Shaozhen Song; William Cepurna; John Morrison; Ruikang K Wang
Journal:  Microvasc Res       Date:  2018-09-26       Impact factor: 3.514

Review 2.  Fourier Domain Mode Locked Laser and Its Applications.

Authors:  Dongmei Huang; Yihuan Shi; Feng Li; P K A Wai
Journal:  Sensors (Basel)       Date:  2022-04-20       Impact factor: 3.847

3.  Advances in Retinal Optical Imaging.

Authors:  Yanxiu Li; Xiaobo Xia; Yannis M Paulus
Journal:  Photonics       Date:  2018-04-27

4.  1.1-µm Band Extended Wide-Bandwidth Wavelength-Swept Laser Based on Polygonal Scanning Wavelength Filter.

Authors:  Gi Hyen Lee; Soyeon Ahn; Jinhwa Gene; Min Yong Jeon
Journal:  Sensors (Basel)       Date:  2021-04-27       Impact factor: 3.576

Review 5.  Enhanced medical diagnosis for dOCTors: a perspective of optical coherence tomography.

Authors:  Rainer Leitgeb; Fabian Placzek; Elisabet Rank; Lisa Krainz; Richard Haindl; Qian Li; Mengyang Liu; Marco Andreana; Angelika Unterhuber; Tilman Schmoll; Wolfgang Drexler
Journal:  J Biomed Opt       Date:  2021-10       Impact factor: 3.758

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.