Literature DB >> 30264363

Changes in left ventricular function in patients with aortic regurgitation 12 months after transapical transcatheter aortic valve implantation.

Ming-Dan Deng1, Xin Wei1, Xiao-Ling Zhang1, Xiao-Dong Li1, Gu-Yue Liu1, Da Zhu2, Ying-Qiang Guo2, Hong Tang3.   

Abstract

Transcatheter aortic valve implantation (TAVI) is an established treatment for high surgical risk aortic stenosis patients; in recent years, it has also been used in patients with pure/dominant aortic regurgitation (AR). This study aimed to determine the impact of transapical TAVI on left ventricle myocardial mechanics in AR patients. Thirty AR patients (70% men; mean age, 72.8 ± 4.3 years) were enrolled. Conventional echocardiography was performed on all patients before and 12 months after TAVI. Three-dimensional speckle tracking was accomplished in 20 AR patients for the evaluation of global longitudinal strain, global circumferential strain, twist, torsion, apical rotation and basal rotation. Preoperative left ventricular ejection fraction (LVEF), global longitudinal strain (GLS), global circumferential strain (GCS), twist, torsion and apical rotation were impaired in AR patients compared with controls. Mean left ventricular (LV) end-diastolic diameter (from 62.9 ± 7.3 to 52.0 ± 6.8 mm, p < 0.001), LV end-diastolic volume (from 199.4 ± 55.0 to 130.1 ± 48.9 mL, p < 0.001), and LV mass index (179.8 ± 52.2-134.4 ± 42.5 g/m2, p = 0.001) decreased 12 months after TAVI. Interestingly, GLS (from - 17.2 ± 3.2 to - 18.9 ± 3.7, p = 0.007) and GCS (from - 23.9 ± 4.9 to - 25.7 ± 5.0, p = 0.008) improved significantly, but LVEF did not significantly improve. In terms of the rotational mechanics, twist, rotation and basal rotation remained almost unchanged, whereas apical rotation (from 7.4 ± 4.0 to 5.5 ± 3.9, p = 0.009) was significantly impaired after transapical TAVI. Our results indicate that LV function was improved in terms of myocardial deformation but worsened in terms of apical rotation 12 months after TAVI in AR patients. Three-dimensional speckle tracking echocardiography appears to be a sensitive method for detecting subtle cardiac remodeling after TAVI.

Entities:  

Keywords:  Aortic regurgitation; Strain; Three-dimensional speckle tracking; Transcatheter aortic valve implantation

Mesh:

Year:  2018        PMID: 30264363     DOI: 10.1007/s10554-018-1445-7

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  3 in total

1.  Reversal of a rheologic cardiomyopathy following hematopoietic stem cell transplantation for sickle cell disease.

Authors:  Vandana Sachdev; Matthew Hsieh; Neal Jeffries; Anna Noreuil; Wen Li; Stanislav Sidenko; Hwaida Hannoush; Emily Limerick; Delon Wilson; John Tisdale; Courtney Fitzhugh
Journal:  Blood Adv       Date:  2019-10-08

2.  Transcatheter aortic valve replacement for aortic regurgitation in Asians: TAVR for aortic regurgitation in Asians.

Authors:  Erica L Soong; Yi Jing Ong; Jamie S Y Ho; Nichola W S Chew; William K F Kong; Tiong-Cheng Yeo; Ping Chai; Edgar L W Tay; Kent Tan; Yinghao Lim; Ivandito Kuntjoro; Ching-Hui Sia
Journal:  AsiaIntervention       Date:  2021-12

Review 3.  Challenges and opportunities in improving left ventricular remodelling and clinical outcome following surgical and trans-catheter aortic valve replacement.

Authors:  Xu Yu Jin; Mario Petrou; Jiang Ting Hu; Ed D Nicol; John R Pepper
Journal:  Front Med       Date:  2021-05-28       Impact factor: 4.592

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.