Literature DB >> 30258330

A Preliminary Comparison Suggests Poor Performance of Carbon Fiber Reinforced Versus Titanium Plates in Distal Femoral Osteotomy.

Austin T Fragomen1,2, Thomas H McCoy3,4, Fiona R Fragomen1.   

Abstract

BACKGROUND: Carbon fiber-reinforced (CFR) polymer implants have theoretical advantages over titanium plates. QUESTIONS/PURPOSES: The aim of the present study was to assess our early outcomes with CFR plates in lateral opening-wedge distal femoral osteotomy to correct valgus lower limb malalignment. We asked the following: (1) Did the CFR polymer implant change time to union when compared with the titanium implant? (2) Did the incidence of displacement of medial cortical fractures differ between the implants? (3) Did the incidence of complications differ between the two techniques, and did other factors, such as bone graft material used, affect healing?
METHODS: A retrospective review of 16 limbs treated with an opening-wedge distal femoral osteotomy for genu valgum using either titanium (n = 10) or CFR plates (n = 6) was performed. Patient and clinical covariates as well as the primary outcome of time to union and secondary outcome of fracture displacement were collected and analyzed.
RESULTS: Those treated with CFR plates had longer times to union than did those in the titanium-treated group (median, 121.5 vs 81.5 days, respectively). The incidence of fracture displacement was higher in the CFR plate-treated group (CFR, n = 5/6; titanium, n = 1/10). Although the CFR plate-treated group had a 33% nonunion incidence while the titanium group had no nonunions, the study lacked the power to show significance. Bone graft material used did not affect outcome. Complication rates were higher in the CFR plate-treated patients.
CONCLUSION: The CFR plate was associated with a longer time to unite and higher fracture displacement rate than the titanium plate. As this is a retrospective case series, further research is required to confirm these results and clarify best practices in plating of distal femoral osteotomy for deformity correction.

Entities:  

Keywords:  bioactive glass; carbon fiber-reinforced plate; distal femoral osteotomy (DFO); genu valgum; titanium plate

Year:  2017        PMID: 30258330      PMCID: PMC6148591          DOI: 10.1007/s11420-017-9587-z

Source DB:  PubMed          Journal:  HSS J        ISSN: 1556-3316


  22 in total

1.  Physical activity after distal femur osteotomy for the treatment of lateral compartment knee osteoarthritis.

Authors:  Lúcio Honório de Carvalho; Eduardo Frois Temponi; Luiz Fernando Machado Soares; Matheus Braga Jacques Gonçalves; Lincoln Paiva Costa
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-12-13       Impact factor: 4.342

2.  Correction of distal femoral valgus deformities in adolescents and young adults using minimally invasive fixator-assisted locking plating (FALP).

Authors:  Mark Eidelman; Yaniv Keren; Doron Norman
Journal:  J Pediatr Orthop B       Date:  2012-11       Impact factor: 1.041

3.  A matched-pair comparison of two different locking plates for valgus-producing medial open-wedge high tibial osteotomy: peek-carbon composite plate versus titanium plate.

Authors:  Matthias Cotic; Stephan Vogt; Stefan Hinterwimmer; Matthias J Feucht; Julia Slotta-Huspenina; Tibor Schuster; Andreas B Imhoff
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-02-22       Impact factor: 4.342

4.  Biomechanical analysis of distal femur fracture fixation: fixed-angle screw-plate construct versus condylar blade plate.

Authors:  Thomas F Higgins; Gavin Pittman; Jerod Hines; Kent N Bachus
Journal:  J Orthop Trauma       Date:  2007-01       Impact factor: 2.512

5.  Stackable carbon fiber cages for thoracolumbar interbody fusion after corpectomy: long-term outcome analysis.

Authors:  Robert F Heary; Arvin Kheterpal; Antonios Mammis; Sanjeev Kumar
Journal:  Neurosurgery       Date:  2011-03       Impact factor: 4.654

6.  Distal femoral varus osteotomy: problems associated with the lateral open-wedge technique.

Authors:  Matthias Jacobi; Peter Wahl; Samy Bouaicha; Roland P Jakob; Emanuel Gautier
Journal:  Arch Orthop Trauma Surg       Date:  2010-10-14       Impact factor: 3.067

Review 7.  [Distal femoral varus osteotomy for symptomatic genu valgum: long-term results and review of the literature].

Authors:  S Zilber; M Larrouy; L Sedel; R Nizard
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  2004-11

8.  Opening wedge distal femoral varus osteotomy for lateral compartment osteoarthritis in the valgus knee.

Authors:  A Saithna; R Kundra; A Getgood; T Spalding
Journal:  Knee       Date:  2013-08-29       Impact factor: 2.199

9.  Femoral deformity planning: intentional placement of the apex of deformity.

Authors:  Peter D Fabricant; James M Camara; S Robert Rozbruch
Journal:  Orthopedics       Date:  2013-05       Impact factor: 1.390

Review 10.  PEEK biomaterials in trauma, orthopedic, and spinal implants.

Authors:  Steven M Kurtz; John N Devine
Journal:  Biomaterials       Date:  2007-08-07       Impact factor: 12.479

View more
  2 in total

1.  Carbon-Fiber-Reinforced Polymer Intramedullary Nails Perform Poorly in Long-Bone Surgery.

Authors:  Austin T Fragomen; Jason Teplensky; S Robert Rozbruch
Journal:  HSS J       Date:  2018-10-12

2.  The Variable Effects of NSAIDs on Osteotomy Healing and Opioid Consumption.

Authors:  Austin Fragomen; Jaehee Suh; Kelsey Matta; Thomas H McCoy; Kamber L Hart; S Robert Rozbruch
Journal:  J Am Acad Orthop Surg Glob Res Rev       Date:  2020-04-06
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.