Literature DB >> 31327940

Carbon-Fiber-Reinforced Polymer Intramedullary Nails Perform Poorly in Long-Bone Surgery.

Austin T Fragomen1, Jason Teplensky2, S Robert Rozbruch1.   

Abstract

BACKGROUND: Carbon-fiber-reinforced (CFR) polymer has produced great excitement in the orthopedic community as a material that will reduce bone healing times and provide improved image quality. Osteotomy stabilized with an intramedullary (IM) nail has become a common technique to address post-traumatic malalignment of the lower extremity. PURPOSES/QUESTIONS: The following questions were asked: (1) Did CFR polymer nails provide a rapid healing time after long bone osteotomy, shortening, or fracture? (2) Did the CFR polymer nails produce unexpected complications?
METHODS: A retrospective review was conducted in patients who received CFR polymer IM nails for various indications, from April 2016 to January 2017 in a deformity and trauma practice, using patient charts and radiographs. The primary outcomes were time to union and incidence of complications including nonunion, hardware failure, neurovascular injury, venous thromboembolism, and infection.
RESULTS: Twelve patients who received CFR polymer IM nails in 16 limbs for various indications were included in our analysis. Patients were followed for an average of 16.9 months. Eleven limbs underwent realignment and were corrected an average of 23° through a diaphyseal osteotomy. Three limbs underwent limb-shortening surgery, an average of 25 mm, through an open, excisional osteotomy of the femoral diaphysis. Two diaphyseal, closed tibia fractures underwent routine IM nailing. The average time to union was 107.6 days, which included all limbs that united (11/16, 69%). Nonunion occurred in 5/16 (31%) of limbs. Complications recorded included nonunion and hardware failure, most of which resulted in unplanned surgery.
CONCLUSIONS: The use of the CFR polymer IM nail was associated with loss of fixation and nonunion after surgeries that have traditionally healed uneventfully. The increased elasticity of the CFR polymer allows for more motion at the osteotomy/fracture interface than the stiffer titanium counterparts, exposing long-bone osteotomies to delayed union and nonunion, a finding seen with CFR polymer plates. The overwhelmingly poor early results of this device applied to a long-bone deformity practice have led these authors to abandon the use of this implant.

Entities:  

Keywords:  carbon fiber reinforced; deformity; intramedullary nailing; nonunion; polymer

Year:  2018        PMID: 31327940      PMCID: PMC6609670          DOI: 10.1007/s11420-018-9634-4

Source DB:  PubMed          Journal:  HSS J        ISSN: 1556-3316


  20 in total

Review 1.  Unicompartmental arthritis of the knee.

Authors:  Richard Iorio; William L Healy
Journal:  J Bone Joint Surg Am       Date:  2003-07       Impact factor: 5.284

2.  Surgical correction of miserable malalignment syndrome.

Authors:  W David Bruce; Peter M Stevens
Journal:  J Pediatr Orthop       Date:  2004 Jul-Aug       Impact factor: 2.324

3.  A matched-pair comparison of two different locking plates for valgus-producing medial open-wedge high tibial osteotomy: peek-carbon composite plate versus titanium plate.

Authors:  Matthias Cotic; Stephan Vogt; Stefan Hinterwimmer; Matthias J Feucht; Julia Slotta-Huspenina; Tibor Schuster; Andreas B Imhoff
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-02-22       Impact factor: 4.342

Review 4.  Use of carbon-fiber-reinforced composite implants in orthopedic surgery.

Authors:  David J Hak; Cyril Mauffrey; David Seligson; Bennie Lindeque
Journal:  Orthopedics       Date:  2014-12       Impact factor: 1.390

5.  Recovery of function after closed femoral shortening.

Authors:  K L Barker; A H R W Simpson
Journal:  J Bone Joint Surg Br       Date:  2004-11

Review 6.  Intramedullary nailing for tibial shaft fractures in adults.

Authors:  Xin Duan; Mohammed Al-Qwbani; Yan Zeng; Wei Zhang; Zhou Xiang
Journal:  Cochrane Database Syst Rev       Date:  2012-01-18

7.  Carbon-fibre reinforced plates for problem fractures.

Authors:  D J Pemberton; B McKibbin; R Savage; K Tayton; D Stuart
Journal:  J Bone Joint Surg Br       Date:  1992-01

8.  Success of torsional correction surgery after failed surgeries for patellofemoral pain and instability.

Authors:  Peter M Stevens; Jeremy M Gililland; Lucas A Anderson; Jennifer B Mickelson; Jenifer Nielson; Joshua W Klatt
Journal:  Strategies Trauma Limb Reconstr       Date:  2013-12-15

9.  Tibial rotational osteotomy with intramedullary nail fixation.

Authors:  Alan K Stotts; Peter M Stevens
Journal:  Strategies Trauma Limb Reconstr       Date:  2009-11-26

10.  Corrective tibial osteotomy in young adults using an intramedullary nail.

Authors:  Kang-Il Kim; Peter H Thaller; Alankar Ramteke; Sang Hak Lee; Seung-Hyuk Lee
Journal:  Knee Surg Relat Res       Date:  2014-05-30
View more
  1 in total

Review 1.  Intramedullary nailing for impending or pathologic fracture of the long bone: titanium vs carbon fiber peek nailing.

Authors:  Elisa Pala; Alberto Procura; Giulia Trovarelli; Antonio Berizzi; Pietro Ruggieri
Journal:  EFORT Open Rev       Date:  2022-08-04
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.