Literature DB >> 21311306

Stackable carbon fiber cages for thoracolumbar interbody fusion after corpectomy: long-term outcome analysis.

Robert F Heary1, Arvin Kheterpal, Antonios Mammis, Sanjeev Kumar.   

Abstract

BACKGROUND: Reconstruction of the thoracolumbar spine after corpectomy is a challenge for fractures, infections, and tumors.
OBJECTIVE: To analyze fusion rates, clinical outcomes, and the percent of vertebral body coverage achieved by using stackable carbon fiber-reinforced polyetheretherketone cages in thoracolumbar corpectomies, and to measure the actual size of the cages and compare this measurement with the size of the vertebra(e) replaced by the cage.
METHODS: A retrospective study of 40 patients who underwent thoracolumbar corpectomies was performed. Preoperative imaging included plain films, computed tomography scans, and magnetic resonance imaging. Postoperatively, plain films and computed tomography scans were obtained, and the width of decompression and cross-sectional area of the cage were measured. The ratio of the area of the cage to the calculated area of the replaced vertebral body was used to determine the percent of vertebral body coverage.
RESULTS: The mean follow-up period was 43 months. Successful fusion was observed in 39 patients. One patient experienced cage subsidence with kyphosis. One additional patient incurred a neurological complication that was corrected without long-term consequence. The mean correction of sagittal alignment was 10°, and the mean width of bony decompression was 20 mm. The mean ratio of the area of the carbon fiber cage to the area of the resected vertebral body was 60%.
CONCLUSION: Stackable carbon fiber cages are effective devices for achieving thoracolumbar fusions. No failures of the cages occurred over long-term follow-up. Excellent clinical and radiographic results were achieved by covering a mean of 60% of the vertebral body with the cage.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21311306     DOI: 10.1227/NEU.0b013e3182077a9f

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  8 in total

1.  Surgical fixation of pathologic and traumatic spinal fractures using single position surgery technique in lateral decubitus position.

Authors:  Alexandra E Thomson; J Alex Thomas; Ivan Ye; Joshua Olexa; Vincent Miseo; Kendall Buraimoh; Daniel L Cavanaugh; Eugene Y Koh; Steven C Ludwig
Journal:  Eur Spine J       Date:  2022-02-05       Impact factor: 2.721

2.  Multivariate analysis of risk factors for predicting supplementary posterior instrumentation after anterolateral decompression and instrumentation in treating thoracolumbar burst fractures.

Authors:  Jiang Chen; Yu-Song Jia; Qi Sun; Jin-Yu Li; Chen-Ying Zheng; Jian Du; Chun-Xiao Bai
Journal:  J Orthop Surg Res       Date:  2015-01-28       Impact factor: 2.359

Review 3.  The Use of Carbon-Fiber-Reinforced (CFR) PEEK Material in Orthopedic Implants: A Systematic Review.

Authors:  Chuan Silvia Li; Christopher Vannabouathong; Sheila Sprague; Mohit Bhandari
Journal:  Clin Med Insights Arthritis Musculoskelet Disord       Date:  2015-02-23

4.  Distal radius plate of CFR-PEEK has minimal effect compared to titanium plates on bone parameters in high-resolution peripheral quantitative computed tomography: a pilot study.

Authors:  Joost J A de Jong; Arno Lataster; Bert van Rietbergen; Jacobus J Arts; Piet P Geusens; Joop P W van den Bergh; Paul C Willems
Journal:  BMC Med Imaging       Date:  2017-02-27       Impact factor: 1.930

5.  Carbon-fiber reinforced PEEK instrumentation for spondylodiscitis: a single center experience on safety and efficacy.

Authors:  Ann-Kathrin Joerger; Ehab Shiban; Sandro M Krieg; Bernhard Meyer
Journal:  Sci Rep       Date:  2021-01-28       Impact factor: 4.379

Review 6.  Carbon Fiber Implants in Orthopaedic Oncology.

Authors:  Caleb M Yeung; Abhiram R Bhashyam; Shalin S Patel; Eduardo Ortiz-Cruz; Santiago A Lozano-Calderón
Journal:  J Clin Med       Date:  2022-08-24       Impact factor: 4.964

7.  A Preliminary Comparison Suggests Poor Performance of Carbon Fiber Reinforced Versus Titanium Plates in Distal Femoral Osteotomy.

Authors:  Austin T Fragomen; Thomas H McCoy; Fiona R Fragomen
Journal:  HSS J       Date:  2017-12-07

8.  Mediation of mechanically adapted TiCu/TiCuN/CFR-PEEK implants in vascular regeneration to promote bone repair in vitro and in vivo.

Authors:  Yu Guo; Chenglong Chen; Shuyuan Zhang; Ling Ren; Yanhui Zhao; Wei Guo
Journal:  J Orthop Translat       Date:  2022-03-08       Impact factor: 5.191

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.