Hongfei Sun1, Kai Xie, Liugang Gao, Jianfeng Sui, Tao Lin, Xinye Ni.
Abstract
This study aimed to investigate the reliability of pseudo-computed tomography (pseudo-CT) imaging based on ultrasound (US) deformation fields under different binary masks in radiotherapy.We used 3-dimensional (3D) CT and US images, including those acquired during CT simulation positioning, and cone-beam CT (CBCT) and US images acquired 1 week after treating 3 patients with cervical cancer. Image data of 3 different layers were selected from the US images, and 3D CT images of each patient were selected. For US image registration, the following were created and applied: binary masks of the region of interest overlapping (ROIO) between the US image based on simulation positioning and US image for positioning verification, region of interest (ROI), whole overlapping (wholeO), and whole imaging region (whole). Accordingly, the deformation field was obtained and applied to CT images (CTsim), and different pseudo-CT images were acquired. Similarities between the pseudo-CT and CBCT images were compared, and registration accuracies between pseudo-CT images under different binary masks and CTsim were compared and discussed.A pair t test was conducted to normalized mutual information values of the registration accuracy between the pseudo-CT image based on ROIO binary mask and CTsim with other methods (P < .05), and the difference was statistically significant. A pair t test of normalized gray mean-squared errors was also performed (P < .05), and the difference was statistically significant. The similarity function means between pseudo-CT, that is, based on ROIO, ROI, wholeO, whole, and no binary mask, and CBCT were 0.9084, 0.8365, 0.7800, 0.6830, and 0.5518, respectively.Pseudo-CT based on ROIO binary mask best matched with CTsim and achieved the highest similarity with CBCT.Entities:
Mesh:
Year: 2018 PMID: 30235776 PMCID: PMC6160174 DOI: 10.1097/MD.0000000000012532
Source DB: PubMed Journal: Medicine (Baltimore) ISSN: 0025-7974 Impact factor: 1.817
Figure 1(A) 3D ultrasound image workstations. (B) Calibration phantom.
Image data of 3 different layers of every patient.
Figure 2(A) CTsim and USsim images under the same coordinate system. (B) CBCT and USpv images under the same coordinate system.
Figure 3(A) Binary masks based on the whole imaging region of USsim. (B) Binary masks based on the whole imaging region of USpv. (C) Binary masks based on ROI of USsim. (D) Binary mask based on ROI of USpv. (E) Binary mask based on wholeO of USsim and USpv. (F) Binary mask based on ROIO of USsim and USpv.
Figure 4(A) Pseudo-CT image based on ROIO. (B) Pseudo-CT images without binary mask. (C) CBCT.
Registration accuracy assessment by NMSE and NMI.
Figure 5Structural difference assessment between pseudo-CT and CBCT by SSIM.