Literature DB >> 30216462

Comparative study of algorithms for synthetic CT generation from MRI: Consequences for MRI-guided radiation planning in the pelvic region.

Hossein Arabi1, Jason A Dowling2, Ninon Burgos3, Xiao Han4, Peter B Greer5,6, Nikolaos Koutsouvelis7, Habib Zaidi1,8,9,10.   

Abstract

PURPOSE: Magnetic resonance imaging (MRI)-guided radiation therapy (RT) treatment planning is limited by the fact that the electron density distribution required for dose calculation is not readily provided by MR imaging. We compare a selection of novel synthetic CT generation algorithms recently reported in the literature, including segmentation-based, atlas-based and machine learning techniques, using the same cohort of patients and quantitative evaluation metrics.
METHODS: Six MRI-guided synthetic CT generation algorithms were evaluated: one segmentation technique into a single tissue class (water-only), four atlas-based techniques, namely, median value of atlas images (ALMedian), atlas-based local weighted voting (ALWV), bone enhanced atlas-based local weighted voting (ALWV-Bone), iterative atlas-based local weighted voting (ALWV-Iter), and a machine learning technique using deep convolution neural network (DCNN).
RESULTS: Organ auto-contouring from MR images was evaluated for bladder, rectum, bones, and body boundary. Overall, DCNN exhibited higher segmentation accuracy resulting in Dice indices (DSC) of 0.93 ± 0.17, 0.90 ± 0.04, and 0.93 ± 0.02 for bladder, rectum, and bones, respectively. On the other hand, ALMedian showed the lowest accuracy with DSC of 0.82 ± 0.20, 0.81 ± 0.08, and 0.88 ± 0.04, respectively. DCNN reached the best performance in terms of accurate derivation of synthetic CT values within each organ, with a mean absolute error within the body contour of 32.7 ± 7.9 HU, followed by the advanced atlas-based methods (ALWV: 40.5 ± 8.2 HU, ALWV-Iter: 42.4 ± 8.1 HU, ALWV-Bone: 44.0 ± 8.9 HU). ALMedian led to the highest error (52.1 ± 11.1 HU). Considering the dosimetric evaluation results, ALWV-Iter, ALWV, DCNN and ALWV-Bone led to similar mean dose estimation within each organ at risk and target volume with less than 1% dose discrepancy. However, the two-dimensional gamma analysis demonstrated higher pass rates for ALWV-Bone, DCNN, ALMedian and ALWV-Iter at 1%/1 mm criterion with 94.99 ± 5.15%, 94.59 ± 5.65%, 93.68 ± 5.53% and 93.10 ± 5.99% success, respectively, while ALWV and water-only resulted in 86.91 ± 13.50% and 80.77 ± 12.10%, respectively.
CONCLUSIONS: Overall, machine learning and advanced atlas-based methods exhibited promising performance by achieving reliable organ segmentation and synthetic CT generation. DCNN appears to have slightly better performance by achieving accurate automated organ segmentation and relatively small dosimetric errors (followed closely by advanced atlas-based methods, which in some cases achieved similar performance). However, the DCNN approach showed higher vulnerability to anatomical variation, where a greater number of outliers was observed with this method. Considering the dosimetric results obtained from the evaluated methods, the challenge of electron density estimation from MR images can be resolved with a clinically tolerable error.
© 2018 American Association of Physicists in Medicine.

Entities:  

Keywords:  CT synthesis; MRI-guided radiotherapy planning; atlas-based; machine learning; segmentation

Mesh:

Year:  2018        PMID: 30216462     DOI: 10.1002/mp.13187

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  17 in total

1.  Novel adversarial semantic structure deep learning for MRI-guided attenuation correction in brain PET/MRI.

Authors:  Hossein Arabi; Guodong Zeng; Guoyan Zheng; Habib Zaidi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2019-07-01       Impact factor: 9.236

2.  Impact of Tissue Classification in MRI-Guided Attenuation Correction on Whole-Body Patlak PET/MRI.

Authors:  Mingzan Zhuang; Nicolas A Karakatsanis; Rudi A J O Dierckx; Habib Zaidi
Journal:  Mol Imaging Biol       Date:  2019-12       Impact factor: 3.488

3.  Deep-JASC: joint attenuation and scatter correction in whole-body 18F-FDG PET using a deep residual network.

Authors:  Isaac Shiri; Hossein Arabi; Parham Geramifar; Ghasem Hajianfar; Pardis Ghafarian; Arman Rahmim; Mohammad Reza Ay; Habib Zaidi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2020-05-15       Impact factor: 9.236

4.  Patch-based generative adversarial neural network models for head and neck MR-only planning.

Authors:  Peter Klages; Ilyes Benslimane; Sadegh Riyahi; Jue Jiang; Margie Hunt; Joseph O Deasy; Harini Veeraraghavan; Neelam Tyagi
Journal:  Med Phys       Date:  2019-12-25       Impact factor: 4.071

5.  MRI-guided attenuation correction in torso PET/MRI: Assessment of segmentation-, atlas-, and deep learning-based approaches in the presence of outliers.

Authors:  Hossein Arabi; Habib Zaidi
Journal:  Magn Reson Med       Date:  2021-09-04       Impact factor: 3.737

Review 6.  A Survey on Deep Learning for Precision Oncology.

Authors:  Ching-Wei Wang; Muhammad-Adil Khalil; Nabila Puspita Firdi
Journal:  Diagnostics (Basel)       Date:  2022-06-17

7.  Feasibility of synthetic computed tomography generated with an adversarial network for multi-sequence magnetic resonance-based brain radiotherapy.

Authors:  Yuhei Koike; Yuichi Akino; Iori Sumida; Hiroya Shiomi; Hirokazu Mizuno; Masashi Yagi; Fumiaki Isohashi; Yuji Seo; Osamu Suzuki; Kazuhiko Ogawa
Journal:  J Radiat Res       Date:  2020-01-23       Impact factor: 2.724

8.  Dosimetric evaluation of synthetic CT generated with GANs for MRI-only proton therapy treatment planning of brain tumors.

Authors:  Samaneh Kazemifar; Ana M Barragán Montero; Kevin Souris; Sara T Rivas; Robert Timmerman; Yang K Park; Steve Jiang; Xavier Geets; Edmond Sterpin; Amir Owrangi
Journal:  J Appl Clin Med Phys       Date:  2020-03-26       Impact factor: 2.102

9.  MRI-based treatment planning for liver stereotactic body radiotherapy: validation of a deep learning-based synthetic CT generation method.

Authors:  Yingzi Liu; Yang Lei; Tonghe Wang; Oluwatosin Kayode; Sibo Tian; Tian Liu; Pretesh Patel; Walter J Curran; Lei Ren; Xiaofeng Yang
Journal:  Br J Radiol       Date:  2019-06-20       Impact factor: 3.039

10.  Transforming UTE-mDixon MR Abdomen-Pelvis Images Into CT by Jointly Leveraging Prior Knowledge and Partial Supervision.

Authors:  Pengjiang Qian; Jiamin Zheng; Qiankun Zheng; Yuan Liu; Tingyu Wang; Rose Al Helo; Atallah Baydoun; Norbert Avril; Rodney J Ellis; Harry Friel; Melanie S Traughber; Ajit Devaraj; Bryan Traughber; Raymond F Muzic
Journal:  IEEE/ACM Trans Comput Biol Bioinform       Date:  2021-02-03       Impact factor: 3.710

View more