Coronary 18F-sodium fluoride (18F-NaF) PET identifies ruptured plaques in patients with recent myocardial infarction and localizes to atherosclerotic lesions with active calcification. Most studies to date have performed the PET acquisition 1 h after injection. Although qualitative and semiquantitative analysis is feasible with 1-h images, residual blood-pool activity often makes it difficult to discriminate plaques with 18F-NaF uptake from noise. We aimed to assess whether delayed PET performed 3 h after injection improves image quality and uptake measurements. Methods: Twenty patients (67 ± 7 y old, 55% male) with stable coronary artery disease underwent coronary CT angiography (CTA) and PET/CT both 1 h and 3 h after the injection of 266.2 ± 13.3 MBq of 18F-NaF. We compared the visual pattern of coronary uptake, maximal background (blood pool) activity, noise, SUVmax, corrected SUVmax (cSUVmax), and target-to-background (TBR) ratio in lesions defined by CTA on 1-h versus 3-h 18F-NaF PET. Results: On 1-h PET, 26 CTA lesions with 18F-NaF PET uptake were identified in 12 (60%) patients. On 3-h PET, we detected 18F-NaF PET uptake in 7 lesions that were not identified on 1-h PET. The median cSUVmax and TBRs of these lesions were 0.48 (interquartile range [IQR], 0.44-0.51) and 1.45 (IQR, 1.39-1.52), respectively, compared with -0.01 (IQR, -0.03-0.001) and 0.95 (IQR, 0.90-0.98), respectively, on 1-h PET (both P < 0.001). Across the entire cohort, 3-h PET SUVmax was similar to 1-h PET measurements (1.63 [IQR, 1.37-1.98] vs. 1.55 [IQR, 1.43-1.89], P = 0.30), and the background activity was lower (0.71 [IQR, 0.65-0.81] vs. 1.24 [IQR, 1.05-1.31], P < 0.001). On 3-h PET, TBR, cSUVmax, and noise were significantly higher (respectively: 2.30 [IQR, 1.70-2.68] vs. 1.28 [IQR, 0.98-1.56], P < 0.001; 0.38 [IQR, 0.27-0.70] vs. 0.90 [IQR, 0.64-1.17], P < 0.001; and 0.10 [IQR, 0.09-0.12] vs. 0.07 [IQR, 0.06-0.09], P = 0.02). Median cSUVmax and TBR increased by 92% (range, 33%-225%) and 80% (range, 20%-177%), respectively. Conclusion: Blood-pool activity decreases on delayed imaging, facilitating the assessment of 18F-NaF uptake in coronary plaques. Median TBR increases by 80%, leading to the detection of more plaques with significant uptake than are detected using the standard 1-h protocol. A greater than 1-h delay may improve the detection of 18F-NaF uptake in coronary artery plaques.
Coronary 18F-sodium fluoride (18F-NaF) PET identifies ruptured plaques in patients with recent myocardial infarction and localizes to atherosclerotic lesions with active calcification. Most studies to date have performed the PET acquisition 1 h after injection. Although qualitative and semiquantitative analysis is feasible with 1-h images, residual blood-pool activity often makes it difficult to discriminate plaques with 18F-NaF uptake from noise. We aimed to assess whether delayed PET performed 3 h after injection improves image quality and uptake measurements. Methods: Twenty patients (67 ± 7 y old, 55% male) with stable coronary artery disease underwent coronary CT angiography (CTA) and PET/CT both 1 h and 3 h after the injection of 266.2 ± 13.3 MBq of 18F-NaF. We compared the visual pattern of coronary uptake, maximal background (blood pool) activity, noise, SUVmax, corrected SUVmax (cSUVmax), and target-to-background (TBR) ratio in lesions defined by CTA on 1-h versus 3-h 18F-NaF PET. Results: On 1-h PET, 26 CTA lesions with 18F-NaF PET uptake were identified in 12 (60%) patients. On 3-h PET, we detected 18F-NaF PET uptake in 7 lesions that were not identified on 1-h PET. The median cSUVmax and TBRs of these lesions were 0.48 (interquartile range [IQR], 0.44-0.51) and 1.45 (IQR, 1.39-1.52), respectively, compared with -0.01 (IQR, -0.03-0.001) and 0.95 (IQR, 0.90-0.98), respectively, on 1-h PET (both P < 0.001). Across the entire cohort, 3-h PET SUVmax was similar to 1-h PET measurements (1.63 [IQR, 1.37-1.98] vs. 1.55 [IQR, 1.43-1.89], P = 0.30), and the background activity was lower (0.71 [IQR, 0.65-0.81] vs. 1.24 [IQR, 1.05-1.31], P < 0.001). On 3-h PET, TBR, cSUVmax, and noise were significantly higher (respectively: 2.30 [IQR, 1.70-2.68] vs. 1.28 [IQR, 0.98-1.56], P < 0.001; 0.38 [IQR, 0.27-0.70] vs. 0.90 [IQR, 0.64-1.17], P < 0.001; and 0.10 [IQR, 0.09-0.12] vs. 0.07 [IQR, 0.06-0.09], P = 0.02). Median cSUVmax and TBR increased by 92% (range, 33%-225%) and 80% (range, 20%-177%), respectively. Conclusion: Blood-pool activity decreases on delayed imaging, facilitating the assessment of 18F-NaF uptake in coronary plaques. Median TBR increases by 80%, leading to the detection of more plaques with significant uptake than are detected using the standard 1-h protocol. A greater than 1-h delay may improve the detection of 18F-NaF uptake in coronary artery plaques.
Authors: R A Hawkins; Y Choi; S C Huang; C K Hoh; M Dahlbom; C Schiepers; N Satyamurthy; J R Barrio; M E Phelps Journal: J Nucl Med Date: 1992-05 Impact factor: 10.057
Authors: Frederick D Grant; Frederic H Fahey; Alan B Packard; Royal T Davis; Abass Alavi; S Ted Treves Journal: J Nucl Med Date: 2007-12-12 Impact factor: 10.057
Authors: James K Min; Leslee J Shaw; Richard B Devereux; Peter M Okin; Jonathan W Weinsaft; Donald J Russo; Nicholas J Lippolis; Daniel S Berman; Tracy Q Callister Journal: J Am Coll Cardiol Date: 2007-09-04 Impact factor: 24.094
Authors: J H F Rudd; E A Warburton; T D Fryer; H A Jones; J C Clark; N Antoun; P Johnström; A P Davenport; P J Kirkpatrick; B N Arch; J D Pickard; P L Weissberg Journal: Circulation Date: 2002-06-11 Impact factor: 29.690
Authors: Jacek Kwiecinski; Damini Dey; Sebastien Cadet; Sang-Eun Lee; Yuka Otaki; Phi T Huynh; Mhairi K Doris; Evann Eisenberg; Mijin Yun; Maurits A Jansen; Michelle C Williams; Balaji K Tamarappoo; John D Friedman; Marc R Dweck; David E Newby; Hyuk-Jae Chang; Piotr J Slomka; Daniel S Berman Journal: JACC Cardiovasc Imaging Date: 2019-02-13
Authors: Jacek Kwiecinski; Damini Dey; Sebastien Cadet; Sang-Eun Lee; Balaji Tamarappoo; Yuka Otaki; Phi T Huynh; John D Friedman; Mark R Dweck; David E Newby; Mijin Yun; Hyuk-Jae Chang; Piotr J Slomka; Daniel S Berman Journal: Eur Heart J Cardiovasc Imaging Date: 2020-01-01 Impact factor: 6.875
Authors: Jacek Kwiecinski; Philip D Adamson; Martin L Lassen; Mhairi K Doris; Alastair J Moss; Sebastian Cadet; Maurits A Jansen; Damini Dey; Sang-Eun Lee; Mijin Yun; Hyuk-Jae Chang; Marc R Dweck; David E Newby; Daniel S Berman; Piotr J Slomka Journal: Circ Cardiovasc Imaging Date: 2018-12 Impact factor: 7.792
Authors: Jacek Kwiecinski; Evangelos Tzolos; Philip D Adamson; Sebastien Cadet; Alastair J Moss; Nikhil Joshi; Michelle C Williams; Edwin J R van Beek; Damini Dey; Daniel S Berman; David E Newby; Piotr J Slomka; Marc R Dweck Journal: J Am Coll Cardiol Date: 2020-06-23 Impact factor: 24.094
Authors: Martin Lyngby Lassen; Jacek Kwiecinski; Damini Dey; Sebastien Cadet; Guido Germano; Daniel S Berman; Philip D Adamson; Alastair J Moss; Marc R Dweck; David E Newby; Piotr J Slomka Journal: Eur J Nucl Med Mol Imaging Date: 2019-08-05 Impact factor: 9.236
Authors: Jacek Kwiecinski; Sebastien Cadet; Marwa Daghem; Martin L Lassen; Damini Dey; Marc R Dweck; Daniel S Berman; David E Newby; Piotr J Slomka Journal: Eur J Nucl Med Mol Imaging Date: 2020-01-02 Impact factor: 9.236
Authors: Evangelos Tzolos; Jacek Kwiecinski; Martin Lyngby Lassen; Sebastien Cadet; Philip D Adamson; Alastair J Moss; Nikhil Joshi; Michelle C Williams; Edwin J R van Beek; Damini Dey; Daniel S Berman; Marc R Dweck; David E Newby; Piotr J Slomka Journal: J Nucl Cardiol Date: 2020-06-11 Impact factor: 5.952