Literature DB >> 30187951

Improved sensitivity and temporal resolution in perfusion FMRI using velocity selective inversion ASL.

Luis Hernandez-Garcia1, Jon-Fredrik Nielsen1, Douglas C Noll1.   

Abstract

PURPOSE: This work aims to investigate the utility of velocity selective inversion pulses for perfusion weighted functional MRI.
METHODS: Tracer kinetic properties of velocity selective inversion (VSI) pulses as an input function for an arterial spin labeling (ASL) experiment were characterized in a group of healthy participants. Numerical simulations were conducted to search for a robust set of timing parameters for FMRI time series acquisition with maximal signal to noise ratio efficiency. The performance of three VSI pulse sequences with different timing parameters was compared with a pseudocontinuous ASL sequence in a simple FMRI experiment conducted on healthy participants.
RESULTS: The fit to the tracer kinetic model yielded arterial CBV of 1.24% ± 0.52% and 0.45 ± 0.11% and perfusion rates of 60.8 ± 32.3 and 34.4 ± 5.4 mL/min/100 g for gray and white matter, respectively. Bolus arrival times were estimated as 75.7 ± 21 ms and 349 ± 78 ms for gray and white matter, respectively. The FMRI experiments showed that VSI pulses yield comparable sensitivity to PCASL with similar timing parameters (TR = 4 s). However, VSI pulses could be used at a faster acquisition speed (TR = 3 s) and were more sensitive to neuronal activity than PCASL pulses, as evidenced by the 31% higher Z scores obtained on average in the active regions.
CONCLUSION: VSI pulses can be very beneficial for perfusion weighted functional MRI because of their tracer kinetic characteristics, which allow a faster acquisition rate while maintaining an efficient labeling input function.
© 2018 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  ASL; VSI; arterial spin labeling; bolus arrival time; brain; functional MRI; perfusion; velocity selective inversion

Year:  2018        PMID: 30187951      PMCID: PMC6289627          DOI: 10.1002/mrm.27461

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  28 in total

1.  Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla.

Authors:  Hanzhang Lu; Chekesha Clingman; Xavier Golay; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2004-09       Impact factor: 4.668

2.  Velocity selective radiofrequency pulse trains.

Authors:  D G Norris; C Schwarzbauer
Journal:  J Magn Reson       Date:  1999-03       Impact factor: 2.229

3.  An optimized velocity selective arterial spin labeling module with reduced eddy current sensitivity for improved perfusion quantification.

Authors:  James A Meakin; Peter Jezzard
Journal:  Magn Reson Med       Date:  2012-05-03       Impact factor: 4.668

4.  B0 field inhomogeneity considerations in pseudo-continuous arterial spin labeling (pCASL): effects on tagging efficiency and correction strategy.

Authors:  Hesamoddin Jahanian; Douglas C Noll; Luis Hernandez-Garcia
Journal:  NMR Biomed       Date:  2011-03-08       Impact factor: 4.044

5.  Multisite evaluations of a T2 -relaxation-under-spin-tagging (TRUST) MRI technique to measure brain oxygenation.

Authors:  Peiying Liu; Ivan Dimitrov; Trevor Andrews; David E Crane; Jacinda K Dariotis; John Desmond; Julie Dumas; Guillaume Gilbert; Anand Kumar; Bradley J Maclntosh; Alan Tucholka; Shaolin Yang; Guanghua Xiao; Hanzhang Lu
Journal:  Magn Reson Med       Date:  2015-04-04       Impact factor: 4.668

6.  Acceleration-selective arterial spin labeling.

Authors:  Sophie Schmid; Eidrees Ghariq; Wouter M Teeuwisse; Andrew Webb; Matthias J P van Osch
Journal:  Magn Reson Med       Date:  2013-03-08       Impact factor: 4.668

7.  An optimized design to reduce eddy current sensitivity in velocity-selective arterial spin labeling using symmetric BIR-8 pulses.

Authors:  Jia Guo; James A Meakin; Peter Jezzard; Eric C Wong
Journal:  Magn Reson Med       Date:  2014-04-07       Impact factor: 4.668

8.  Determination of whole-brain oxygen extraction fractions by fast measurement of blood T(2) in the jugular vein.

Authors:  Qin Qin; Ksenija Grgac; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2010-11-30       Impact factor: 4.668

9.  Challenges to attention: a continuous arterial spin labeling (ASL) study of the effects of distraction on sustained attention.

Authors:  Elise Demeter; Luis Hernandez-Garcia; Martin Sarter; Cindy Lustig
Journal:  Neuroimage       Date:  2010-09-17       Impact factor: 6.556

10.  Perfusion by Arterial Spin labelling following Single dose Tadalafil In Small vessel disease (PASTIS): study protocol for a randomised controlled trial.

Authors:  Mathilde M H Pauls; Natasha Clarke; Sarah Trippier; Shai Betteridge; Franklyn A Howe; Usman Khan; Christina Kruuse; Jeremy B Madigan; Barry Moynihan; Anthony C Pereira; Debbie Rolfe; Egill Rostrup; Caroline E Haig; Thomas R Barrick; Jeremy D Isaacs; Atticus H Hainsworth
Journal:  Trials       Date:  2017-05-22       Impact factor: 2.279

View more
  10 in total

1.  Improved velocity-selective-inversion arterial spin labeling for cerebral blood flow mapping with 3D acquisition.

Authors:  Dapeng Liu; Feng Xu; Wenbo Li; Peter C van Zijl; Doris D Lin; Qin Qin
Journal:  Magn Reson Med       Date:  2020-05-13       Impact factor: 4.668

2.  In vivo magnetic resonance imaging and spectroscopy. Technological advances and opportunities for applications continue to abound.

Authors:  Peter van Zijl; Linda Knutsson
Journal:  J Magn Reson       Date:  2019-07-09       Impact factor: 2.229

3.  Ensuring both velocity and spatial responses robust to B 0 / B 1 + field inhomogeneities for velocity-selective arterial spin labeling through dynamic phase-cycling.

Authors:  Dapeng Liu; Wenbo Li; Feng Xu; Dan Zhu; Taehoon Shin; Qin Qin
Journal:  Magn Reson Med       Date:  2020-12-08       Impact factor: 4.668

Review 4.  Image registration in dynamic renal MRI-current status and prospects.

Authors:  Frank G Zöllner; Amira Šerifović-Trbalić; Gordian Kabelitz; Marek Kociński; Andrzej Materka; Peter Rogelj
Journal:  MAGMA       Date:  2019-10-09       Impact factor: 2.310

5.  Influence of the cardiac cycle on velocity selective and acceleration selective arterial spin labeling.

Authors:  Suzanne L Franklin; Sophie Schmid; Clemens Bos; Matthias J P van Osch
Journal:  Magn Reson Med       Date:  2019-09-04       Impact factor: 4.668

6.  Multi-organ comparison of flow-based arterial spin labeling techniques: Spatially non-selective labeling for cerebral and renal perfusion imaging.

Authors:  Suzanne L Franklin; Isabell K Bones; Anita A Harteveld; Lydiane Hirschler; Marijn van Stralen; Qin Qin; Anneloes de Boer; Johannes M Hoogduin; Clemens Bos; Matthias J P van Osch; Sophie Schmid
Journal:  Magn Reson Med       Date:  2020-11-30       Impact factor: 4.668

7.  T2 -oximetry-based cerebral venous oxygenation mapping using Fourier-transform-based velocity-selective pulse trains.

Authors:  Wenbo Li; Feng Xu; Dan Zhu; Peter C M van Zijl; Qin Qin
Journal:  Magn Reson Med       Date:  2022-05-24       Impact factor: 3.737

Review 8.  Recent Technical Developments in ASL: A Review of the State of the Art.

Authors:  Luis Hernandez-Garcia; Verónica Aramendía-Vidaurreta; Divya S Bolar; Weiying Dai; Maria A Fernández-Seara; Jia Guo; Ananth J Madhuranthakam; Henk Mutsaerts; Jan Petr; Qin Qin; Jonas Schollenberger; Yuriko Suzuki; Manuel Taso; David L Thomas; Matthias J P van Osch; Joseph Woods; Moss Y Zhao; Lirong Yan; Ze Wang; Li Zhao; Thomas W Okell
Journal:  Magn Reson Med       Date:  2022-08-19       Impact factor: 3.737

Review 9.  Velocity-selective arterial spin labeling perfusion MRI: A review of the state of the art and recommendations for clinical implementation.

Authors:  Qin Qin; David C Alsop; Divya S Bolar; Luis Hernandez-Garcia; James Meakin; Dapeng Liu; Krishna S Nayak; Sophie Schmid; Matthias J P van Osch; Eric C Wong; Joseph G Woods; Greg Zaharchuk; Moss Y Zhao; Zungho Zun; Jia Guo
Journal:  Magn Reson Med       Date:  2022-07-12       Impact factor: 3.737

10.  Magnetic resonance angiography and perfusion mapping by arterial spin labeling using Fourier transform-based velocity-selective pulse trains: Examination on a commercial perfusion phantom.

Authors:  Feng Xu; Dan Zhu; Hongli Fan; Hanzhang Lu; Dapeng Liu; Wenbo Li; Qin Qin
Journal:  Magn Reson Med       Date:  2021-05-02       Impact factor: 4.668

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.