Aaron J Grossberg1,2, Abdallah S R Mohamed1,3, Hesham Elhalawani1, William C Bennett4, Kirk E Smith4, Tracy S Nolan4, Bowman Williams1, Sasikarn Chamchod1,5, Jolien Heukelom1,6, Michael E Kantor1, Theodora Browne1, Katherine A Hutcheson7, G Brandon Gunn1, Adam S Garden1, William H Morrison1, Steven J Frank1, David I Rosenthal1, John B Freymann8, Clifton D Fuller1.
Abstract
Cross sectional imaging is essential for the patient-specific planning and delivery of radiotherapy, a primary determinant of head and neck cancer outcomes. Due to challenges ensuring data quality and patient de-identification, publicly available datasets including diagnostic and radiation treatment planning imaging are scarce. In this data descriptor, we detail the collection and processing of computed tomography based imaging in 215 patients with head and neck squamous cell carcinoma that were treated with radiotherapy. Using cross sectional imaging, we calculated total body skeletal muscle and adipose content before and after treatment. We detail techniques for validating the high quality of these data and describe the processes of data de-identification and transfer. All imaging data are subject- and date-matched to clinical data from each patient, including demographics, risk factors, grade, stage, recurrence, and survival. These data are a valuable resource for studying the association between patient-specific anatomic and metabolic features, treatment planning, and oncologic outcomes, and the first that allows for the integration of body composition as a risk factor or study outcome.Entities:
Mesh:
Year: 2018 PMID: 30179230 PMCID: PMC6190723 DOI: 10.1038/sdata.2018.173
Source DB: PubMed Journal: Sci Data ISSN: 2052-4463 Impact factor: 6.444
Figure 1Schema representation of image collection and analysis workflow.
Description of data categories in (DICOM Imaging Output Detail, Data Citation 1).
| Data Category | Description (Tag) |
|---|---|
| SUBJECT_ID | Patient ID number randomly assigned to each patient prior to anonymizing the DICOM PHI tag (0010,0020) |
| Origin of retrieved DICOM image file. ORIGINAL=DICOM file directly collected from scanner; DERIVED=reconstructed or reformatted DICOM file; NULL=DICOM-RT file constructed from RT planning software (0008,0008) | |
| Type of equipment that originally acquired the data used to create the images in this Series. CT=computed tomography; PT=positron emission tomography; MR=magnetic resonance imaging; RTPLAN=beams, collimation, energy, and monitor units delivered; RTSTRUCT=physician- and dosimetrist-contoured target and avoidance volumes, RTDOSE=isodose lines (0008,0060) | |
| Number of images in the study (0020,1002) | |
| Date study was performed after standard date offset was applied to original DICOM file. (0008,0020) | |
| Institution-generated description or classification of the Study (component) performed. (0008,1030) | |
| Description of series from each study. (0008,103E) | |
| Numerical assignment for each series. (0020,0011) | |
| Unique ID number for study generated during DICOM anonymization (0020,000D) | |
| Unique ID number for series generated during DICOM anonymization (0020,000E) | |
| Manufacturer of scanner used to obtain image. DICOM-RT files are generated in treatment planning software and listed as ADAC. (0008,0070) | |
| Model of scanner used to obtain DICOM files. DICOM-RT files are generated in treatment planning software and listed as Pinnacle3. (0008,1090) | |
| Software version used for construction of the DICOM file. (0018,1020) | |
| Type of DICOM object (0008,0008) | |
| X-ray tube voltage used for the acquisition of DICOM file (0018,0060) | |
| Parameters of scanning sequence. (0018,0022) | |
| The diameter in mm of the region over which data were collected (0018,0022) | |
| Diameter in mm of the region from within which data were used in creating the reconstruction of the image. Data may exist outside this region and portions of the patient may exist outside this region. (0018,1100) | |
| Distance in mm from source to detector center (0018,1110) | |
| Angle of tilt in degrees of the scanning gantry. (degrees). (0018,1120) | |
| Direction of rotation of the source about nearest principal axis of equipment. CW=clockwise CC=counter clockwise (0018,1140) | |
| Time of x-ray exposure in msec (0018,1150) | |
| Motion of the table (in mm) during a complete revolution of the source around the gantry orbit. (0018,9310) | |
| Radiopharmaceutical used in positron-emission tomography scan. (0018,0031) | |
| The radiopharmaceutical dose administered to the patient measured in MegaBecquerels (MBq) (0018,1074). | |
| Half life of radiopharmaceutical, in seconds.(0018,1075) | |
| The radionuclide positron fraction (fraction of decays that are by positron emission)(0018,1076) | |
| Field of view shape. (0018,1147) | |
| Field of view diameter specified for image acquisition. (0018,1149) | |
| Collimator type. (0018,1181) | |
| Field of view diameter specified for PET image reconstruction (0018,1181) |