Literature DB >> 30174997

Handheld Retinal Oximetry in Healthy Young Adults.

Wouter Vehmeijer1, Sveinn Hakon Hardarson2, Kelly Jonkman3, Leon Aarts3, Albert Dahan3, Einar Stefánsson4, Nicoline Schalij-Delfos1.   

Abstract

PURPOSE: The objective of this study was to measure the relative retinal oxygen saturation with a prototype, mobile handheld oximeter in upright and supine position and to compare these measurements to the gold standard Oxymap T1 retinal oximeter in upright position. A handheld oximeter is needed for measurements of infants with retinopathy of prematurity as well as acutely injured and bedridden adults.
METHODS: Healthy volunteers (age 18-35) were recruited at the Leiden University Medical Center. Retinal images were acquired with the handheld oximeter and the Oxymap T1. Both cameras are dual-wavelength oximeters and acquire images with wavelengths of 570 and 600 nm. Retinal oxygen saturation values were determined for both the handheld camera and the Oxymap T1.
RESULTS: Twenty-one subjects (age 25 ± 2 years) were included. In upright position, the oxygen saturation for the arterioles was 92.2% to 4.9% vs. 95.5% ± 4.2% and for the venules 57.9% ± 10.2% vs. 57.7% ± 6.4% for the handheld camera and Oxymap T1, respectively. The oxygen saturation was higher in the arterioles than the venules for both cameras (P < 0.05). In supine position, measured with the handheld oximeter, the oxygen saturation in the arterioles was 92.3% ± 5.8% and 59.2% ± 6.1% in the venules.
CONCLUSIONS: Performance of the prototype, mobile handheld oximeter Corimap camera compares well with the Oxymap T1, with a slightly larger standard deviation in oxygen saturation measurements, both in upright and supine patients. TRANSLATION RELEVANCE: To date, to our knowledge, no oximeters are available for handheld use and for measurement in supine position in infants and bedridden adults. Here we tested such an oximeter and show that its performance compares well with that of the gold standard Oxymap T1 in healthy adults.

Entities:  

Keywords:  dual-wavelength oximetry; handheld oximetry; retinal oximetry

Year:  2018        PMID: 30174997      PMCID: PMC6114026          DOI: 10.1167/tvst.7.4.19

Source DB:  PubMed          Journal:  Transl Vis Sci Technol        ISSN: 2164-2591            Impact factor:   3.283


  19 in total

1.  Oxygen saturation in central retinal vein occlusion.

Authors:  Sveinn Hakon Hardarson; Einar Stefánsson
Journal:  Am J Ophthalmol       Date:  2010-09-26       Impact factor: 5.258

2.  Retinal vessel oximetry-calibration, compensation for vessel diameter and fundus pigmentation, and reproducibility.

Authors:  Martin Hammer; Walthard Vilser; Thomas Riemer; Dietrich Schweitzer
Journal:  J Biomed Opt       Date:  2008 Sep-Oct       Impact factor: 3.170

3.  Retinal oxygen metabolism in healthy subjects and glaucoma patients.

Authors:  Olof Birna Olafsdottir; Evelien Vandewalle; Luis Abegão Pinto; Asbjorg Geirsdottir; Eline De Clerck; Peter Stalmans; Maria Soffia Gottfredsdottir; Jona Valgerdur Kristjansdottir; Joachim Van Calster; Thierry Zeyen; Einar Stefánsson; Ingeborg Stalmans
Journal:  Br J Ophthalmol       Date:  2014-01-08       Impact factor: 4.638

4.  How to prevent retinopathy of prematurity.

Authors:  Einar Stefánsson
Journal:  Acta Ophthalmol       Date:  2011-02       Impact factor: 3.761

5.  Reliability and determinants of retinal vessel oximetry measurements in healthy eyes.

Authors:  WanFen Yip; Rosalynn Siantar; Shamira A Perera; Nia Milastuti; Kee Ka Ho; Bernard Tan; Tien Yin Wong; Carol Y Cheung
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-10-09       Impact factor: 4.799

6.  Retinal oxygen metabolism in exudative age-related macular degeneration.

Authors:  Asbjorg Geirsdottir; Sveinn Hakon Hardarson; Olof Birna Olafsdottir; Einar Stefánsson
Journal:  Acta Ophthalmol       Date:  2013-11-06       Impact factor: 3.761

7.  Retinal oximetry images must be standardized: a methodological analysis.

Authors:  Olafur Palsson; Asbjorg Geirsdottir; Sveinn Hakon Hardarson; Olof Birna Olafsdottir; Jona Valgerdur Kristjansdottir; Einar Stefánsson
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-04-02       Impact factor: 4.799

8.  Pathway to Retinal Oximetry.

Authors:  James Beach
Journal:  Transl Vis Sci Technol       Date:  2014-09-03       Impact factor: 3.283

9.  Retinal oximetry in primary open-angle glaucoma.

Authors:  Olof Birna Olafsdottir; Sveinn Hakon Hardarson; Maria Soffia Gottfredsdottir; Alon Harris; Einar Stefánsson
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-08-16       Impact factor: 4.799

10.  Retinal Oximetry with Scanning Laser Ophthalmoscope in Infants.

Authors:  Wouter B Vehmeijer; Vigdis Magnusdottir; Thorunn S Eliasdottir; Sveinn Hakon Hardarson; Nicoline E Schalij-Delfos; Einar Stefánsson
Journal:  PLoS One       Date:  2016-02-03       Impact factor: 3.240

View more
  2 in total

Review 1.  Advances in Retinal Oximetry.

Authors:  Anupam K Garg; Darren Knight; Leonardo Lando; Daniel L Chao
Journal:  Transl Vis Sci Technol       Date:  2021-02-05       Impact factor: 3.283

2.  Retinal oximetry with a prototype handheld oximeter during hyperoxia.

Authors:  Wouter B Vehmeijer; Kelly Jonkman; Sveinn H Hardarson; Leon Aarts; Einar Stefansson; Albert Dahan; Nicoline E Schalij-Delfos
Journal:  Acta Ophthalmol       Date:  2021-03-01       Impact factor: 3.988

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.