Literature DB >> 22395877

Retinal oximetry images must be standardized: a methodological analysis.

Olafur Palsson1, Asbjorg Geirsdottir, Sveinn Hakon Hardarson, Olof Birna Olafsdottir, Jona Valgerdur Kristjansdottir, Einar Stefánsson.   

Abstract

PURPOSE: Retinal vessel oximetry is a new technology and needs detailed methodological scrutiny. We determine (1) the repeatability of retinal vessel oxygen saturation measurements, (2) whether measured saturation is different between retinal quadrants, and (3) whether the angle of gaze changes measurements of the same vessels.
METHODS: Fundus oximetry images were obtained from 26 healthy individuals, 18 to 30 years old, using the Oxymap retinal oximeter. Oxygen saturation in the same vessel segments was compared between two similar images of each individual to determine repeatability. Vessel oxygen saturation was also compared between different quadrants of the retina in the same oximetry image. Finally, oxygen saturation measurements were made on the same vessel segments at different angles of gaze.
RESULTS: Mean and standard deviation of saturation measurements was 93.1% ± 2.3% in arterioles and 64.9% ± 3.3% in venules. Standard deviation of repeated saturation measurements on the same vessel segment was 1.0% in arterioles and 1.4% in venules. Significant differences were seen between retinal quadrants. When angle of gaze was altered, measured saturation was lower in the same vessels when they were located in the inferior portion compared with other parts of the image (-1.3% ± 1.7%, P = 0.0004 in arterioles and -1.9 ± 2.4%, P = 0.0007 in venules).
CONCLUSIONS: Retinal vessel oxygen saturation measurements are repeatable with a small standard deviation. When oximetry results are compared between time points or eyes, the imaging must be standardized and similar parts of the images analyzed.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22395877     DOI: 10.1167/iovs.11-8621

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  25 in total

1.  Visible light optical coherence tomography angiography (vis-OCTA) facilitates local microvascular oximetry in the human retina.

Authors:  Weiye Song; Wenjun Shao; Wei Yi; Rongrong Liu; Manishi Desai; Steven Ness; Ji Yi
Journal:  Biomed Opt Express       Date:  2020-06-30       Impact factor: 3.732

2.  Venous oxygen saturation is reduced and variable in central retinal vein occlusion.

Authors:  Thorunn Scheving Eliasdottir; David Bragason; Sveinn Hakon Hardarson; Gudrun Kristjansdottir; Einar Stefánsson
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-11-18       Impact factor: 3.117

3.  Noninvasive assessment of retinal vascular oxygen content among normal and diabetic human subjects: a study using hyperspectral computed tomographic imaging spectroscopy.

Authors:  Amir H Kashani; Gilberto R Lopez Jaime; Saloomeh Saati; Gabriel Martin; Rohit Varma; Mark S Humayun
Journal:  Retina       Date:  2014-09       Impact factor: 4.256

4.  Retinal Vascular Oxygen Saturation and Its Variation With Refractive Error and Axial Length.

Authors:  Laurence Shen Lim; Xian Hui Lim; Licia Tan
Journal:  Transl Vis Sci Technol       Date:  2019-08-07       Impact factor: 3.283

5.  Handheld Retinal Oximetry in Healthy Young Adults.

Authors:  Wouter Vehmeijer; Sveinn Hakon Hardarson; Kelly Jonkman; Leon Aarts; Albert Dahan; Einar Stefánsson; Nicoline Schalij-Delfos
Journal:  Transl Vis Sci Technol       Date:  2018-08-27       Impact factor: 3.283

6.  Retinal oximetry using ultrahigh-resolution optical coherence tomography.

Authors:  Yufeng Ye; Hong Jiang; Meixiao Shen; Byron L Lam; Delia Cabrera Debuc; Lili Ge; Mitra Sehi; Jianhua Wang
Journal:  Clin Ophthalmol       Date:  2012-12-12

7.  Retinal Oximetry in a Healthy Japanese Population.

Authors:  Yuki Nakano; Takeru Shimazaki; Nobuko Kobayashi; Yukiko Miyoshi; Aoi Ono; Mamoru Kobayashi; Chieko Shiragami; Kazuyuki Hirooka; Akitaka Tsujikawa
Journal:  PLoS One       Date:  2016-07-19       Impact factor: 3.240

8.  The Changes of Retinal Saturation after Long-Term Tamponade with Silicone Oil.

Authors:  Bingsheng Lou; Zhaohui Yuan; Liwen He; Lixia Lin; Qianying Gao; Xiaofeng Lin
Journal:  Biomed Res Int       Date:  2015-10-18       Impact factor: 3.411

9.  External beam radiotherapy for head and neck cancers is associated with increased variability in retinal vascular oxygenation.

Authors:  Daniel S Higginson; Alok Sahgal; Michael V Lawrence; Sarah Moyer; Mihaela Stefanescu; Adam K Willson; Bahjat Qaqish; Adam Zanation; Lawrence B Marks; Seema Garg; Bhishamjit S Chera
Journal:  PLoS One       Date:  2013-08-06       Impact factor: 3.240

10.  Retinal Oximetry with Scanning Laser Ophthalmoscope in Infants.

Authors:  Wouter B Vehmeijer; Vigdis Magnusdottir; Thorunn S Eliasdottir; Sveinn Hakon Hardarson; Nicoline E Schalij-Delfos; Einar Stefánsson
Journal:  PLoS One       Date:  2016-02-03       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.