| Literature DB >> 30157184 |
Kehui Deng1,2,3,4,5, Hu Chen1,2,3,4,5, Yijiao Zhao1,2,3,4,5, Yongsheng Zhou2,3,5, Yong Wang1,2,3,4,5, Yuchun Sun1,2,3,4,5.
Abstract
OBJECTIVE: To quantitatively evaluate maxillary complete dentures fabricated from polylactic acid (PLA) using fused deposition modelling (FDM) technology.Entities:
Mesh:
Substances:
Year: 2018 PMID: 30157184 PMCID: PMC6114293 DOI: 10.1371/journal.pone.0201777
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Fig 1CAD data of complete denture.
Fig 2FDM machine and the angle of printing.
Fig 3(a) PLA pattern of complete denture; (b) wax pattern of complete denture.
Fig 43D deviation analysis of the thickness of the silicone film in Geomagic, green areas show good matching, red indicates a positive error, blue a negative error.
(a) overall; (b) primary stress-bearing area; (c) secondary stress-bearing area; (d) relief area; (e) border seal area.
Error in the two printing methods: Deviation between the pattern of complete dentures and CAD data.
| Number | Deviation (mm) | |||
|---|---|---|---|---|
| PLA pattern group | Wax pattern group | |||
| mean value | RMS | mean value | RMS | |
| 1 | 0.010 | 0.129 | -0.031 | 0.134 |
| 2 | 0.018 | 0.141 | -0.015 | 0.12 |
| 3 | 0.020 | 0.157 | -0.026 | 0.12 |
| 4 | 0.009 | 0.141 | -0.010 | 0.124 |
| 5 | 0.021 | 0.146 | -0.005 | 0.132 |
| Mean | 0.016 ± 0.007 | 0.143±0.01 | -0.017 ± 0.011 | 0.126±0.007 |
Average deviation between the tissue surface of the denture pattern and the plaster model.
| Area | Deviation (mm) | P value | |
|---|---|---|---|
| PLA pattern group | Wax pattern group | ||
| Overall | 0.277 ± 0.021 | 0.279 ± 0.045 | 0.930 |
| Primary stress-bearing area | 0.296 ± 0.035 | 0.344 ± 0.061 | 0.168 |
| Secondary stress-bearing area | 0.213 ± 0.021 | 0.247 ± 0.064 | 0.294 |
| Relief area | 0.269 ± 0.061 | 0.257 ± 0.065 | 0.785 |
| Border seal area | 0.338 ± 0.025 | 0.291 ± 0.053 | 0.114 |
Fig 5(a) the tissue surface view of complete denture with insufficient prosthetic space (b) improper individual sockets in the base for the teeth are generated (3Shape Dental System 2017, 3Shape, Denmark).