Literature DB >> 30152793

Performance assessment of a software-based coincidence processor for the EXPLORER total-body PET scanner.

Edwin K Leung1, Martin S Judenhofer, Simon R Cherry, Ramsey D Badawi.   

Abstract

Coincidence processing in positron emission tomography (PET) is typically done during acquisition of the data. However, on the EXPLORER total-body PET scanner we plan, in addition, to store unpaired single events (i.e. singles) for post-acquisition coincidence processing. A software-based coincidence processor was developed for EXPLORER and its performance was assessed. Our results showed that the performance of the coincidence processor could be significantly impacted by the type of data storage (Peripheral Component Interconnect Express (PCIe)-attached solid state drive (SSD) versus RAID 6 hard disk drives (HDDs)) especially when multiple data files were processed in parallel. We showed that a 48-thread computer node with dual Intel Xeon E5-2650 v4 central processing units (CPUs) and a PCIe SSD was sufficient to process approximately 120 M singles s-1 at an incoming singles rate of approximately 150 Mcps. With two computer nodes, near real-time coincidence processing became possible at this incoming singles rate.

Entities:  

Mesh:

Year:  2018        PMID: 30152793      PMCID: PMC6354919          DOI: 10.1088/1361-6560/aadd3c

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Basic applications of the chi-square statistic using counting data.

Authors:  M A Tries; K W Skrable; C S French; G E Chabot
Journal:  Health Phys       Date:  1999-10       Impact factor: 1.316

2.  A true singles list-mode data acquisition system for a small animal PET scanner with independent crystal readout.

Authors:  D P McElroy; M Hoose; W Pimpl; V Spanoudaki; T Schüler; S I Ziegler
Journal:  Phys Med Biol       Date:  2005-07-06       Impact factor: 3.609

3.  Redesign of the GATE PET coincidence sorter.

Authors:  Jared Strydhorst; Irène Buvat
Journal:  Phys Med Biol       Date:  2016-09-02       Impact factor: 3.609

4.  Optimal whole-body PET scanner configurations for different volumes of LSO scintillator: a simulation study.

Authors:  Jonathan K Poon; Magnus L Dahlbom; William W Moses; Karthik Balakrishnan; Wenli Wang; Simon R Cherry; Ramsey D Badawi
Journal:  Phys Med Biol       Date:  2012-06-07       Impact factor: 3.609

5.  Towards component-based validation of GATE: aspects of the coincidence processor.

Authors:  Eder R Moraes; Jonathan K Poon; Karthikayan Balakrishnan; Wenli Wang; Ramsey D Badawi
Journal:  Phys Med       Date:  2014-09-18       Impact factor: 2.685

  5 in total
  4 in total

1.  Field-programable-gate-array-based distributed coincidence processor for high count-rate online positron emission tomography coincidence data acquisition.

Authors:  Xinyi Cheng; Kun Hu; Dongxu Yang; Yiping Shao
Journal:  Phys Med Biol       Date:  2021-02-16       Impact factor: 3.609

2.  Quantitative Assessment of Myocardial Ischemia With Positron Emission Tomography.

Authors:  Jae Ho Sohn; Spencer C Behr; Miguel Hernandez Pampaloni; Youngho Seo
Journal:  J Thorac Imaging       Date:  2021-01-22       Impact factor: 5.528

3.  Performance assessment of the 2 γpositronium imaging with the total-body PET scanners.

Authors:  P Moskal; D Kisielewska; R Y Shopa; Z Bura; J Chhokar; C Curceanu; E Czerwiński; M Dadgar; K Dulski; J Gajewski; A Gajos; M Gorgol; R Del Grande; B C Hiesmayr; B Jasińska; K Kacprzak; A Kamińska; Ł Kapłon; H Karimi; G Korcyl; P Kowalski; N Krawczyk; W Krzemień; T Kozik; E Kubicz; P Małczak; M Mohammed; Sz Niedźwiecki; M Pałka; M Pawlik-Niedźwiecka; M Pędziwiatr; L Raczyński; J Raj; A Ruciński; S Sharma; S Shivani; M Silarski; M Skurzok; E Ł Stępień; S Vandenberghe; W Wiślicki; B Zgardzińska
Journal:  EJNMMI Phys       Date:  2020-06-30

4.  Lutetium background radiation in total-body PET-A simulation study on opportunities and challenges in PET attenuation correction.

Authors:  Negar Omidvari; Li Cheng; Edwin K Leung; Yasser G Abdelhafez; Ramsey D Badawi; Tianyu Ma; Jinyi Qi; Simon R Cherry
Journal:  Front Nucl Med       Date:  2022-08-10
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.