Literature DB >> 30112708

Comparison of 4D Flow MRI and Particle Image Velocimetry Using an In Vitro Carotid Bifurcation Model.

Rafael Medero1,2,3, Carson Hoffman4, Alejandro Roldán-Alzate5,6,7.   

Abstract

Four-dimensional (4D) Flow magnetic resonance imaging (MRI) enables the acquisition and assessment of complex hemodynamics in vivo from different vascular territories. This study investigated the viability of stereoscopic and tomographic particle image velocimetry (stereo- and tomo-PIV, respectively) as experimental validation techniques for 4D Flow MRI. The experiments were performed using continuous and pulsatile flows through an idealized carotid artery bifurcation model. Transverse and longitudinal planes were extracted from the acquired velocity data sets at different regions of interest and were analyzed with a point-by-point comparison. An overall root-mean-square error (RMSE) was calculated resulting in errors as low as 0.06 and 0.03 m/s when comparing 4D Flow MRI with stereo- and tomo-PIV, respectively. Quantitative agreement between techniques was determined by evaluating the relationship for individual velocity components and their magnitudes. These resulted in correlation coefficients (R2) of 4D Flow MRI with stereo- and tomo-PIV, as low as 0.76 and 0.73, respectively. The 3D velocity measurements from PIV showed qualitative agreement when compared to 4D Flow MRI, especially with tomo-PIV due to the addition of volumetric velocity measurements. These results suggest that tomo-PIV can be used as a validation technique for 4D Flow MRI, serving as the basis for future validation protocols.

Entities:  

Keywords:  4D flow MRI; Experimental validation; Hemodynamics; Stereoscopic PIV; Tomographic PIV

Mesh:

Year:  2018        PMID: 30112708     DOI: 10.1007/s10439-018-02109-9

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  6 in total

1.  In Vitro Assessment of Flow Variability in an Intracranial Aneurysm Model Using 4D Flow MRI and Tomographic PIV.

Authors:  Rafael Medero; Katrina Ruedinger; David Rutkowski; Kevin Johnson; Alejandro Roldán-Alzate
Journal:  Ann Biomed Eng       Date:  2020-06-10       Impact factor: 3.934

2.  Modeling Physiological Flow Variation in Fontan Models with 4d Flow Mri, Particle Image Velocimetry, and Arterial Spin Labeling.

Authors:  David Rutkowski; Rafael Medero; Timothy Ruesink; Alejandro Roldan-Alzate
Journal:  J Biomech Eng       Date:  2019-10-01       Impact factor: 2.097

3.  Virtual Reality Cardiac Surgical Planning Software (CorFix) for Designing Patient-Specific Vascular Grafts: Development and Pilot Usability Study.

Authors:  Byeol Kim; Phong Nguyen; Yue-Hin Loke; Vincent Cleveland; Xiaolong Liu; Paige Mass; Narutoshi Hibino; Laura Olivieri; Axel Krieger
Journal:  JMIR Cardio       Date:  2022-06-17

4.  A phantom study comparing radial trajectories for accelerated cardiac 4D flow MRI against a particle imaging velocimetry reference.

Authors:  Philip A Corrado; Rafael Medero; Kevin M Johnson; Christopher J François; Alejandro Roldán-Alzate; Oliver Wieben
Journal:  Magn Reson Med       Date:  2021-02-05       Impact factor: 3.737

5.  Influence of Spatial Resolution and Compressed SENSE Acceleration Factor on Flow Quantification with 4D Flow MRI at 3 Tesla.

Authors:  Mariya S Pravdivtseva; Franziska Gaidzik; Philipp Berg; Patricia Ulloa; Naomi Larsen; Olav Jansen; Jan-Bernd Hövener; Mona Salehi Ravesh
Journal:  Tomography       Date:  2022-02-10

Review 6.  Imaging Modalities for Intracranial Aneurysm: More Than Meets the Eye.

Authors:  Clémence Maupu; Héloïse Lebas; Yacine Boulaftali
Journal:  Front Cardiovasc Med       Date:  2022-02-15
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.