| Literature DB >> 30103597 |
So Yoon Park1, Boo-Kyung Han1, Eun Sook Ko1, Eun Young Ko1, Eun Yoon Cho2.
Abstract
PURPOSE: The purpose of this study was to investigate the final outcomes of magnetic resonance imaging (MRI)-identified additional lesions (MRALs) in breast cancer patients and the role of second-look ultrasound (SLUS) and imaging-guided interventions.Entities:
Keywords: Breast neoplasms; Magnetic resonance imaging; Ultrasonography
Year: 2018 PMID: 30103597 PMCID: PMC6323310 DOI: 10.14366/usg.18002
Source DB: PubMed Journal: Ultrasonography ISSN: 2288-5919
Fig. 1.Work-up for MRI-identified additional lesions.
MRI, magnetic resonance imaging; US, ultrasound; FU, follow-up. a)Calcifications were retrospectively detected on mammography after MRI revealed abnormal findings.
Final outcomes of MRALs (n=119)
| No. of cases(%) | Malignancy rate (%) | P-value | |
|---|---|---|---|
| MRI BI-RADS category | |||
| 4A | 48 (40.3) | 54.2 | <0.001 (overall) |
| 4B | 34 (28.6) | 58.8 | 0.847 (4A vs. 4B) |
| 4C | 21 (17.6) | 90.5 | 0.015 (4B vs. 4C) |
| 5 | 16 (13.4) | 100 | 0.496 (4C vs. 5) |
| 4A-4B | 82 (68.9) | 56.1 | <0.001 |
| 4C-5 | 37 (31.1) | 94.6 | |
| Position of MRALs | |||
| Ipsilateral same quadrant | 38 (31.9) | 84.2 | <0.001 |
| Ipsilateral different quadrant | 60 (50.4) | 70.0 | |
| Contralateral | 21 (17.6) | 33.3 | |
| Second-look US | |||
| MRI-concordant lesions (+) | 85 (71.4) | 67.1 | 0.271 |
| MRI-concordant lesions (-) | 9 (7.6) | 44.4 | |
| Not done | 25 (21.0) | 80.0 | |
| Imaging-guided intervention | |||
| Yes | 82 (68.9) | 61.0 | 0.012 |
| No | 37 (31.1) | 83.8 | |
| Total | 119 (100) | 68.1 |
MRALs, MRI-identified suspicious additional lesions; MRI, magnetic resonance imaging; BI-RADS, Breast Imaging Reporting and Database System; US, ultrasound.
Total mastectomy rate in breast cancer patients with ipsilateral MRALs (n=98)
| No. of cases (%) | Total mastectomy | Breast-conserving surgery | P-value | |
|---|---|---|---|---|
| MRI BI-RADS category | ||||
| 4A | 35 (35.7) | 9 (25.7) | 26 (74.3) | 0.003 (overall) |
| 4B | 27 (27.6) | 6 (22.2) | 21 (77.8) | |
| 4C | 20 (20.4) | 11 (55.0) | 9 (45.0) | |
| 5 | 16 (16.3) | 11 (68.8) | 5 (31.3) | |
| 4A-4B | 62 (63.3) | 15 (24.2) | 47 (75.8) | <0.001 |
| 4C-5 | 36 (36.7) | 22 (61.1) | 14 (38.9) | |
| Position of MRALs | ||||
| Ipsilateral same quadrant | 38 (38.8) | 11 (28.9) | 27 (71.1) | 0.152 |
| Ipsilateral different quadrant | 60 (61.2) | 26 (43.3) | 34 (56.7) | |
| Imaging-guided intervention | ||||
| Yes | 61 (62.2) | 17 (27.9) | 44 (72.1) | 0.017 |
| No | 37 (37.8) | 20 (54.1) | 17 (45.9) | |
| Total | 98 (100) | 37 (37.8) | 61 (62.2) |
Values are presented as number (%).
MRALs, MRI-identified suspicious additional lesions; MRI, magnetic resonance imaging; BI-RADS, Breast Imaging Reporting and Database System.