| Literature DB >> 30100556 |
Kunliang Qiu1,2, Binyao Chen1, Jianling Yang1, Ce Zheng1,3, Haoyu Chen1, Mingzhi Zhang4, Nomdo M Jansonius2.
Abstract
PURPOSE: To determine the influence of the optic disc-fovea distance (DFD) on the normative classifications based on thickness measurements of macular inner retinal layers with spectral-domain optical coherence tomography (OCT) in healthy subjects.Entities:
Keywords: glaucoma; macular inner retinal layer; normative database; optic disc-fovea distance; retinal ganglion cell; spectral domain-OCT
Mesh:
Year: 2018 PMID: 30100556 PMCID: PMC6582723 DOI: 10.1136/bjophthalmol-2018-312162
Source DB: PubMed Journal: Br J Ophthalmol ISSN: 0007-1161 Impact factor: 4.638
Characteristics of the study population (n=182)
| Mean±SD | Range | |
| Age, years | 43.8±15.6 | 20–78 |
| Refractive error (dioptre) | −0.80±1.92 | −6.00 to 2.75 |
| Axial length (mm) | 23.63±1.11 | 20.74–26.70 |
| Visual field mean deviation (dB) | −1.15±1.23 | −6.67 to 1.78 |
| DFD (mm) | 4.90±0.29 | 3.98–5.66 |
| FDA (°) | 9.60±3.48 | −2.56 to 21.10 |
| Disc area (mm2) | 2.24±0.39 | 1.28–3.28 |
| Average pRNFL (μm) | 107.6±8.8 | 79–131 |
| GCC scan image quality | 57.8±4.3 | 45–66 |
| Average mRNFL (μm) | 36.7±4.0 | 27–48 |
| Average GCIPL (μm) | 69.7±4.6 | 57–82 |
| Average GCC (μm) | 106.5±7.0 | 89–121 |
DFD, disc–fovea distance; GCC, ganglion cell complex; GCIPL, ganglion cell-inner plexiform layer; mRNFL, macular retinal nerve fibre layer; pRNFL, peripapillary retinal nerve fibre layer.
Associations between DFD and the average thickness of the macular inner retinal layers, adjusted for axial length, optic disc area, FDA, age, gender, image quality, visual field mean deviation and average pRNFL thickness (n=182; partial correlation analysis)
| r | P values | |
| Total mRNFL | −0.49 | <0.001 |
| Superior mRNFL | −0.39 | <0.001 |
| Inferior mRNFL | −0.50 | <0.001 |
| Total GCIPL | −0.28 | <0.001 |
| Superior GCIPL | −0.25 | 0.001 |
| Inferior GCIPL | −0.28 | <0.001 |
| Total GCC | −0.46 | <0.001 |
| Superior GCC | −0.39 | <0.001 |
| Inferior GCC | −0.49 | <0.001 |
DFD, disc–fovea distance; FDA, fovea–disc angle; GCC, ganglion cell complex; mRNFL, macular retinal nerve fibre layer; pRNFL, peripapillary retinal nerve fibre layer.
Figure 1Percentages of eyes classified as abnormal according to the four optical coherence tomography parameters (superior thickness, inferior thickness, total thickness and cluster in thickness deviation map) for the macular retinal nerve fibre layer (mRNFL), ganglion cell-inner plexiform layer (GCIPL) and ganglion cell complex (GCC).
Factors associated with an abnormal normative classification based on the thickness deviation map of the macular inner retinal layers mRNFL, GCIPL and GCC (n=182; logistic regression analysis)
| OR (95% CI) | P values | |
| mRNFL | ||
| DFD (per 0.1 mm) | 1.30 (1.13 to 1.50) | <0.001 |
| Disc area (per mm2) | 0.18 (0.07 to 0.49) | <0.001 |
| GCIPL | ||
| DFD (per 0.1 mm) | 1.18 (1.02 to 1.38) | 0.023 |
| Age (per year) | 1.05 (1.03 to 1.09) | 0.001 |
| pRNFL (per μm) | 0.90 (0.85 to 0.95) | 0.02 |
| Gender (female) | 2.39 (1.01 to 5.62) | 0.037 |
| Axial length (per mm) | 2.10 (1.32 to 3.31) | <0.001 |
| GCC | ||
| DFD (per 0.1 mm) | 1.29 (1.08 to 1.55) | 0.006 |
| pRNFL (per μm) | 0.87 (0.82 to 0.92) | <0.001 |
| Age (per year) | 1.04 (1.01 to 1.07) | 0.008 |
DFD, disc–fovea distance; GCC, ganglion cell complex; GCIPL, ganglion cell-inner plexiform layer; mRNFL, macular retinal nerve fibre layer; pRNFL, peripapillary retinal nerve fibre layer.
Figure 2Four cases demonstrating the association between the DFD and the occurrence of abnormal normative classifications in the optical coherence tomography printout. DFD, disc–fovea distance; GCL, ganglion cell layer; RNFL, retinal nerve fibre layer.