Literature DB >> 21873658

Profile and predictors of normal ganglion cell-inner plexiform layer thickness measured with frequency-domain optical coherence tomography.

Jean-Claude Mwanza1, Mary K Durbin, Donald L Budenz, Christopher A Girkin, Christopher K Leung, Jeffrey M Liebmann, James H Peace, John S Werner, Gadi Wollstein.   

Abstract

PURPOSE: To describe the profile and identify the predictors of the ganglion cell-inner plexiform layer (GCIPL) thickness measured with frequency-domain optical coherence tomography (FD-OCT) in normal eyes.
METHODS: Two hundred eighty-two normal subjects underwent macular and optic disc scanning in both eyes with Cirrus high-definition (HD)-OCT (Carl Zeiss Meditec, Dublin, CA). Linear regression analyses were performed to determine the association between GCIPL thickness and age, sex, ethnicity (Europeans, Africans, Hispanics, Asians, and Indians), eye laterality, refraction, intraocular pressure, axial length, central corneal thickness, mean retinal nerve fiber layer (RNFL) thickness, disc and rim areas, cup-to-disc area, vertical and horizontal cup-to-disc diameter ratios, vertical rim thickness, and OCT signal strength.
RESULTS: The mean (±SD) age was 46.2 ± 16.9 years (range, 18-84 years). The mean and minimum GCIPL thicknesses (±SD) were 82.1 ± 6.2 and 80.4 ± 6.4 μm, respectively. There were significant differences in GCIPL thickness between macular sectors (P < 0.05), except between the superotemporal and inferonasal sectors (P = 0.63). The superonasal sector had the thickest and the inferior had the thinnest GCIPL. The GCIPL of the superior hemisphere was thicker than that of the inferior, and the nasal sector GCIPL was significantly thicker than the temporal one (P < 0.001). The average GCIPL did not differ between male and female subjects (P = 0.16) after adjustment for axial length and between ethnic groups (P = 0.41) after adjustment for age, axial length, and RNFL thickness. Significant predictors of mean GCIPL thickness were average RNFL thickness (β = 0.37, P < 0.001), age (β = -0.083, P < 0.001), axial length (β = -0.87, P = 0.001), and male sex (β = -1.62, P = 0.005).
CONCLUSIONS: The independent factors associated with thinner GCIPL include thinner RNFL, older age, longer ocular axial length, and being male. Although the magnitude of the effect of age, axial length, and sex are small, these factors should be taken into account when interpreting Cirrus HD-OCT-based GCIPL thickness measurements.

Entities:  

Mesh:

Year:  2011        PMID: 21873658     DOI: 10.1167/iovs.11-7896

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  78 in total

1.  A comparison of false positives in retinal nerve fiber layer, optic nerve head and macular ganglion cell-inner plexiform layer from two spectral-domain optical coherence tomography devices.

Authors:  Marina Leal-Fonseca; Gema Rebolleda; Noelia Oblanca; Javier Moreno-Montañes; Francisco J Muñoz-Negrete
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-12-12       Impact factor: 3.117

2.  Effect of age on individual retinal layer thickness in normal eyes as measured with spectral-domain optical coherence tomography.

Authors:  Nazli Demirkaya; Hille W van Dijk; Sanne M van Schuppen; Michael D Abràmoff; Mona K Garvin; Milan Sonka; Reinier O Schlingemann; Frank D Verbraak
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-07-22       Impact factor: 4.799

3.  Difference in correspondence between visual field defect and inner macular layer thickness measured using three types of spectral-domain OCT instruments.

Authors:  Kaori Ueda; Akiyasu Kanamori; Azusa Akashi; Yuki Kawaka; Yuko Yamada; Makoto Nakamura
Journal:  Jpn J Ophthalmol       Date:  2014-11-07       Impact factor: 2.447

4.  Correlation between depth and area of retinal nerve fiber layer defect as measured by spectral domain optical coherence tomography.

Authors:  Min Hee Suh; Byeong Wook Yoo; Ki Ho Park; Jung Yup Kim; Hyunjoong Kim; Hee Chan Kim
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-03-22       Impact factor: 3.117

5.  Normative optical coherence tomography measurements in children.

Authors:  Gadi Wollstein; Joel S Schuman
Journal:  Br J Ophthalmol       Date:  2012-03-17       Impact factor: 4.638

6.  Tracking changes over time in retinal nerve fiber layer and ganglion cell-inner plexiform layer thickness in multiple sclerosis.

Authors:  Divya Narayanan; Han Cheng; Karlie N Bonem; Roberto Saenz; Rosa A Tang; Laura J Frishman
Journal:  Mult Scler       Date:  2014-03-17       Impact factor: 6.312

7.  Measurement of retinal nerve fiber layer and macular ganglion cell-inner plexiform layer with spectral-domain optical coherence tomography in patients with optic nerve head drusen.

Authors:  Alfonso Casado; Gema Rebolleda; Laura Guerrero; Marina Leal; Inés Contreras; Noelia Oblanca; Francisco J Muñoz-Negrete
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-08-17       Impact factor: 3.117

8.  The shape of the ganglion cell plus inner plexiform layers of the normal human macula.

Authors:  Robert W Knighton; Giovanni Gregori
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-10-30       Impact factor: 4.799

9.  Diagnostic specificities of retinal nerve fiber layer, optic nerve head, and macular ganglion cell-inner plexiform layer measurements in myopic eyes.

Authors:  Ahmad A Aref; Fouad E Sayyad; Jean-Claude Mwanza; William J Feuer; Donald L Budenz
Journal:  J Glaucoma       Date:  2014 Oct-Nov       Impact factor: 2.503

10.  Focal alteration of the intraretinal layers in neurodegenerative disorders.

Authors:  Shriya Airen; Ce Shi; Zhiping Liu; Bonnie E Levin; Joseph F Signorile; Jianhua Wang; Hong Jiang
Journal:  Ann Eye Sci       Date:  2020-03
View more