Literature DB >> 300994

Some characteristics of the C-wave of ERGs recorded by a pair of electrodes on the cornea and sclera.

Y Honda.   

Abstract

Light-evoked responses of the rabbit retina in situ were recorded between the electrode on the longitudinal line of the nasal (positive) and the electrode on the opposite longitudinal line of the temporal side (negative). The c-wave was negative and the a-, b-wave was reversed when the negative (temporal) electrode was closer to the corneal center than the positive (nasal) electrode. The c-wave decreased its amplitude as the positive electrode came to the same latitudinal position as that of the negative one. Then, the c-wave was cancelled out in appearance on the recordings. When the negative electrode moved further into the posterior pole, the polarities of the c-wave as well as of the a-, b-wave were returned to those of routine ERGs.

Entities:  

Mesh:

Year:  1977        PMID: 300994     DOI: 10.1007/bf00496765

Source DB:  PubMed          Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol        ISSN: 0065-6100


  5 in total

1.  [Some characteristics of the electroretinogram recorded by a pair of electrodes on the sclera (author's transl)].

Authors:  Y Honda
Journal:  Nippon Ganka Gakkai Zasshi       Date:  1976-05-10

2.  [Radial distribution of the electroretinogram of rabbits followed by reference electrodes on the sclera (author's transl)].

Authors:  Y Honda; K Okada
Journal:  Nippon Ganka Gakkai Zasshi       Date:  1976

3.  [Computer application in clinical electroretinography].

Authors:  B Schmidt; W Straub
Journal:  Klin Monbl Augenheilkd       Date:  1970       Impact factor: 0.700

Review 4.  The eclectroretinogram: its components and their origins.

Authors:  K T Brown
Journal:  Vision Res       Date:  1968-06       Impact factor: 1.886

5.  [Studies on the local electric response of the human retina. I. An instrument for stimulating local retinal areas in various photic conditions].

Authors:  M Nagata; Y Honda
Journal:  Nippon Ganka Gakkai Zasshi       Date:  1970-04
  5 in total
  3 in total

1.  Performance of the DTL electrode compared to the jet contact lens electrode in clinical testing.

Authors:  Hang Yin; Machelle T Pardue
Journal:  Doc Ophthalmol       Date:  2004-01       Impact factor: 2.379

2.  The importance of electrode position in visual electrophysiology.

Authors:  A Kurtenbach; S Kramer; T Strasser; E Zrenner; H Langrová
Journal:  Doc Ophthalmol       Date:  2017-02-21       Impact factor: 2.379

3.  Variability of the multifocal electroretinogram based on the type and position of the electrode.

Authors:  Ángel García-García; Francisco José Muñoz-Negrete; Gema Rebolleda
Journal:  Doc Ophthalmol       Date:  2016-09-24       Impact factor: 2.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.