Variability of the multifocal electroretinogram based on the type and position of the electrode.

Ángel García-García1, Francisco José Muñoz-Negrete2, Gema Rebolleda2.   

Abstract

PURPOSE: To evaluate and compare the wave amplitude of multifocal electroretinogram (mfERG) measurements and discomfort from Dawson-Trick-Litzkow (DTL) electrode located on the cornea (cDTL) and on the conjunctival fornix (fDTL) and ERG-jet contact lens electrode (CL).
METHODS: Thirty-six patients and 18 healthy volunteers were evaluated with three different methods (cDTL, fDTL and CL). Wave amplitude, number of artifacts, number of electrode dislocations and level of discomfort obtained with each electrode were compared. These variables were also compared between patients and healthy volunteers (control group). Comparisons between wave amplitudes were made using intraclass correlation coefficient (ICC).
RESULTS: Responses by the three tested electrode were better correlated (ICC) in patient (0.616-0.756) than in control groups (0.342-0.679). CL provided the highest wave amplitude in both groups (p < 0.005), but it was associated with higher discomfort (p < 0.001) and the highest rate of dislocations (72 and 100 % in control and patients, respectively). Looking at the differences obtained by each electrode between both groups, CL seems to be able to differentiate patient from control in the ring 1 of the mfERG. By contrast, fDTL gave the lowest wave amplitude in both groups, but it had the advantage to, apparently, discriminate between patients and control group in rings 1 and 2. cDTL produced more artifacts than the other electrodes in both groups (p < 0.001).
CONCLUSIONS: Although wave amplitude measurements with different electrodes were correlated, they cannot be directly compared, so it is mandatory to create an appropriate normative database with each electrode. Despite providing the lowest amplitudes, fDTL seems to offer the best features to perform mfERG regarding discomfort, number of artifacts and diagnostic capability.

Entities:  

Keywords:  Amplitude; Discomfort; Electrodes; Multifocal electroretinogram; Variability

Mesh:

Year:  2016        PMID: 27665467     DOI: 10.1007/s10633-016-9560-z

Source DB:  PubMed          Journal:  Doc Ophthalmol        ISSN: 0012-4486            Impact factor:   2.379


  15 in total

1.  Technical aspects of multifocal ERG recording.

Authors:  D Keating; S Parks; A Evans
Journal:  Doc Ophthalmol       Date:  2000       Impact factor: 2.379

2.  Performance of the DTL electrode compared to the jet contact lens electrode in clinical testing.

Authors:  Hang Yin; Machelle T Pardue
Journal:  Doc Ophthalmol       Date:  2004-01       Impact factor: 2.379

3.  The field topography of ERG components in man--I. The photopic luminance response.

Authors:  E E Sutter; D Tran
Journal:  Vision Res       Date:  1992-03       Impact factor: 1.886

4.  [Multifocal ERG using ERG-jet and Gold Foil electrodes in normal subjects: comparison and reproducibility].

Authors:  C Thimonier; P Daubas; L Bourdon; V Deral-Stephant; J-P Menu; R Vignal; C Roux
Journal:  J Fr Ophtalmol       Date:  2008-06       Impact factor: 0.818

5.  [Reproducibility of the pattern electroretinogram].

Authors:  T Otto; M Bach
Journal:  Ophthalmologe       Date:  1997-03       Impact factor: 1.059

6.  The effect of gold foil electrode position on the electroretinogram in human subjects.

Authors:  A McAllan; J Sinn; G W Aylward
Journal:  Vision Res       Date:  1989       Impact factor: 1.886

7.  Some characteristics of the C-wave of ERGs recorded by a pair of electrodes on the cornea and sclera.

Authors:  Y Honda
Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol       Date:  1977-03-29

Review 8.  ISCEV standard for clinical multifocal electroretinography (mfERG) (2011 edition).

Authors:  Donald C Hood; Michael Bach; Mitchell Brigell; David Keating; Mineo Kondo; Jonathan S Lyons; Michael F Marmor; Daphne L McCulloch; Anja M Palmowski-Wolfe
Journal:  Doc Ophthalmol       Date:  2011-10-30       Impact factor: 2.379

9.  Comparison of performance and patient satisfaction of two types of ERG electrodes.

Authors:  P Beeler; D Barthelmes; F K Sutter; H Helbig; J C Fleischhauer
Journal:  Klin Monbl Augenheilkd       Date:  2007-04       Impact factor: 0.700

10.  Nociceptive sensation and sensitivity evoked from human cornea and conjunctiva stimulated by CO2.

Authors:  Yunwei Feng; Trefford L Simpson
Journal:  Invest Ophthalmol Vis Sci       Date:  2003-02       Impact factor: 4.799

View more
  4 in total

1.  Identification of clusters in multifocal electrophysiology recordings to maximize discriminant capacity (patients vs. control subjects).

Authors:  M Ortiz Del Castillo; B Cordón; E M Sánchez Morla; E Vilades; M J Rodrigo; C Cavaliere; L Boquete; E Garcia-Martin
Journal:  Doc Ophthalmol       Date:  2019-09-19       Impact factor: 2.379

2.  Foveal amplitudes of multifocal electroretinograms are larger following full-field electroretinograms.

Authors:  Wendy Harrison; Kaila Osmotherly; Nathan Biancardi; Jamison Langston; Russell Gray; Taylor Kneip; Reese Loveless
Journal:  Doc Ophthalmol       Date:  2018-10-10       Impact factor: 2.379

3.  Effects of DTL electrode position on the amplitude and implicit time of the electroretinogram.

Authors:  Anna H Brouwer; Gerard C de Wit; Joke H de Boer; Maria M van Genderen
Journal:  Doc Ophthalmol       Date:  2019-11-04       Impact factor: 2.379

4.  All-printed stretchable corneal sensor on soft contact lenses for noninvasive and painless ocular electrodiagnosis.

Authors:  Kyunghun Kim; Ho Joong Kim; Haozhe Zhang; Woohyun Park; Dawn Meyer; Min Ku Kim; Bongjoong Kim; Heun Park; Baoxing Xu; Pete Kollbaum; Bryan W Boudouris; Chi Hwan Lee
Journal:  Nat Commun       Date:  2021-03-09       Impact factor: 14.919

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.