Literature DB >> 30095992

Multilayer flow modulator enhances vital organ perfusion in patients with type B aortic dissection.

Farhad Rikhtegar Nezami1, Lambros S Athanasiou1,2, Junedh M Amrute1,3, Elazer R Edelman1,2.   

Abstract

Management of aortic dissections (AD) is still challenging, with no universally approved guideline among possible surgical, endovascular, or medical therapies. Approximately 25% of patients with AD suffer postintervention malperfusion syndrome or hemodynamic instability, with the risk of sudden death if left untreated. Part of the issue is that vascular implants may themselves induce flow disturbances that critically impact vital organs. A multilayer mesh construct might obviate the induced flow disturbances, and it is this concept we investigated. We used preintervention and post-multilayer flow modulator implantation (PM) geometries from clinical cases of type B AD. In-house semiautomatic segmentation routines were applied to computed tomography images to reconstruct the lumen. The device was numerically reconstructed and adapted to the PM geometry concentrically fit to the true lumen centerline. We also numerically designed a pseudohealthy case, where the geometry of the aorta was extracted interpolating geometric features of preintervention, postimplantation, and published representative healthy volunteers. Computational fluid dynamics methods were used to study the time-dependent flow patterns, shear stress metrics, and perfusion to vital organs. A three-element Windkessel lumped parameter module was coupled to a finite-volume solver to assign dynamic outlet boundary conditions. Multilayer flow modulator not only significantly reduced false lumen blood flow, eliminated local flow disturbances, and globally regulated wall shear stress distribution but also maintained physiological perfusion to peripheral vital organs. We propose further investigation to focus the management of AD on both modulation of blood flow and restoration of physiologic end-organ perfusion rather than mere restoration of vascular lamina morphology. NEW & NOTEWORTHY The majority of aortic dissection modeling efforts have focused on the maintenance of physiological flow using minimally invasive placed grafts. The multilayer flow modulator is a complex mesh construct of wires, designed to eliminate flow disruptions in the lumen, regulate the physiological wall stresses, and enhance endothelial function and offering the promise of improved perfusion of vital organs. This has never been fully proved or modeled, and these issues we confirmed using a dynamic framework of time-varying arterial waveforms.

Entities:  

Keywords:  aortic dissection; flow rate; malperfusion; multilayer flow modulator

Mesh:

Year:  2018        PMID: 30095992      PMCID: PMC6461207          DOI: 10.1152/ajpheart.00199.2018

Source DB:  PubMed          Journal:  Am J Physiol Heart Circ Physiol        ISSN: 0363-6135            Impact factor:   4.733


  72 in total

1.  In vivo analysis of mechanical wall stress and abdominal aortic aneurysm rupture risk.

Authors:  Mark F Fillinger; M L Raghavan; Steven P Marra; Jack L Cronenwett; Francis E Kennedy
Journal:  J Vasc Surg       Date:  2002-09       Impact factor: 4.268

2.  Use of computational fluid dynamics studies in predicting aneurysmal degeneration of acute type B aortic dissections.

Authors:  Eric K Shang; Derek P Nathan; Ronald M Fairman; Joseph E Bavaria; Robert C Gorman; Joseph H Gorman; Benjamin M Jackson
Journal:  J Vasc Surg       Date:  2015-04-30       Impact factor: 4.268

3.  Fluid-structure interaction analysis of turbulent pulsatile flow within a layered aortic wall as related to aortic dissection.

Authors:  Khalil Khanafer; Ramon Berguer
Journal:  J Biomech       Date:  2009-09-17       Impact factor: 2.712

Review 4.  Computational evaluation of aortic aneurysm rupture risk: what have we learned so far?

Authors:  Efstratios Georgakarakos; Christos V Ioannou; Yannis Papaharilaou; Theodoros Kostas; Asterios N Katsamouris
Journal:  J Endovasc Ther       Date:  2011-04       Impact factor: 3.487

5.  Fluid-structure interaction based study on the physiological factors affecting the behaviors of stented and non-stented thoracic aortic aneurysms.

Authors:  Xiaohong Wang; Xiaoyang Li
Journal:  J Biomech       Date:  2011-06-30       Impact factor: 2.712

Review 6.  Acute type B aortic dissection: insights from the International Registry of Acute Aortic Dissection.

Authors:  Akshar Y Patel; Kim A Eagle; Prashant Vaishnava
Journal:  Ann Cardiothorac Surg       Date:  2014-07

7.  Endovascular repair of complicated chronic distal aortic dissections: intermediate outcomes and complications.

Authors:  Woong Chol Kang; Roy K Greenberg; Tara M Mastracci; Matthew J Eagleton; Adrian V Hernandez; Akshat C Pujara; Eric E Roselli
Journal:  J Thorac Cardiovasc Surg       Date:  2011-05-05       Impact factor: 5.209

8.  A propensity-matched comparison of outcomes for fenestrated endovascular aneurysm repair and open surgical repair of complex abdominal aortic aneurysms.

Authors:  Maxime Raux; Virendra I Patel; Frédéric Cochennec; Shankha Mukhopadhyay; Pascal Desgranges; Richard P Cambria; Jean-Pierre Becquemin; Glenn M LaMuraglia
Journal:  J Vasc Surg       Date:  2014-05-15       Impact factor: 4.268

9.  Early malperfusion, ischemia reperfusion injury, and respiratory failure in acute complicated type B aortic dissection after thoracic endovascular repair.

Authors:  Jiang Xiong; Minhong Zhang; Wei Guo; Xiaoping Liu; Tai Yin; Xin Jia; Hongpeng Zhang; Yongle Xu; Lijun Wang
Journal:  J Cardiothorac Surg       Date:  2013-01-23       Impact factor: 1.637

10.  Computational tools for clinical support: a multi-scale compliant model for haemodynamic simulations in an aortic dissection based on multi-modal imaging data.

Authors:  Mirko Bonfanti; Stavroula Balabani; John P Greenwood; Sapna Puppala; Shervanthi Homer-Vanniasinkam; Vanessa Díaz-Zuccarini
Journal:  J R Soc Interface       Date:  2017-11       Impact factor: 4.118

View more
  6 in total

1.  Position Paper Computational Cardiology.

Authors:  Lambros Athanasiou; Farhad Rikhtegar Nezami; Elazer R Edelman
Journal:  IEEE J Biomed Health Inform       Date:  2018-10-19       Impact factor: 5.772

2.  Simulation of Fluid-Structure Interaction in Extracorporeal Membrane Oxygenation Circulatory Support Systems.

Authors:  Farhad R Nezami; Mehdi Ramezanpour; Farhan Khodaee; Efrat Goffer; Elazer R Edelman; Steven P Keller
Journal:  J Cardiovasc Transl Res       Date:  2021-06-14       Impact factor: 3.216

3.  A Computational Fluid Dynamics Study of the Extracorporeal Membrane Oxygenation-Failing Heart Circulation.

Authors:  Farhad Rikhtegar Nezami; Farhan Khodaee; Elazer R Edelman; Steven P Keller
Journal:  ASAIO J       Date:  2021-03-01       Impact factor: 3.826

4.  Geometric Analysis of Type B Aortic Dissections Shows Aortic Remodeling After Intervention Using Multilayer Stents.

Authors:  Victor S Costache; Jorn P Meekel; Andreea Costache; Tatiana Melnic; Crina Solomon; Anca M Chitic; Cristian Bucurenciu; Horatiu Moldovan; Iulian Antoniac; Gabriela Candea; Kak K Yeung
Journal:  Materials (Basel)       Date:  2020-05-15       Impact factor: 3.623

5.  Endovascular repair during complex thoracic aortic dissection using a micropore stent graft: Midterm follow-up clinical outcomes.

Authors:  Zhe Wang; Cheng Wang; Fenghe Li; Yu Zhao
Journal:  Catheter Cardiovasc Interv       Date:  2019-08-13       Impact factor: 2.692

6.  The effect of beta-blockers on hemodynamic parameters in patient-specific blood flow simulations of type-B aortic dissection: a virtual study.

Authors:  Mohammad Amin Abazari; Deniz Rafieianzab; M Soltani; Mona Alimohammadi
Journal:  Sci Rep       Date:  2021-08-06       Impact factor: 4.379