Literature DB >> 21722905

Fluid-structure interaction based study on the physiological factors affecting the behaviors of stented and non-stented thoracic aortic aneurysms.

Xiaohong Wang1, Xiaoyang Li.   

Abstract

Endovascular aneurysm repair (EVAR) is considered as a promising alternative technique for the treatment of aortic aneurysm. However, complications often occur after EVAR. In this paper, the influence of the physiological factors on the biomechanical behaviors of stented and non-stented thoracic aortic aneurysm (TAA) were presented. Representative TAA models with different intraluminal thrombus (ILT) volume before and after stent-graft (SG) implantation were built. Fluid-structure interaction effect was taken into account. The relative sliding between the SG wall and the aortic wall was allowed. Results showed that the cardiac cycle and ILT volume should be given much more consideration than previously thought in future investigations on TAA compliance. The time-averaged longitudinal displacement of SG necks were not uniformly distributed along circumferential direction of the aortic wall. Drag force increased with the increase of the cardiac cycle and decreased with the decrease of ILT volume. Computational results of TAA wall stress, sac and lumen pressure indicated that patient with faster heart rate might be at great risk of aneurysm rupture. The stress absorption effect of the SG was influenced by both ILT and cardiac cycle, which was also found to have strong impact on flow pattern. We believe that this study will bring new insights into further researches on the relevant issues and provide mechanics-based implications for clinical management of EVAR for TAA patient.
Copyright © 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21722905     DOI: 10.1016/j.jbiomech.2011.06.020

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  4 in total

1.  Multilayer flow modulator enhances vital organ perfusion in patients with type B aortic dissection.

Authors:  Farhad Rikhtegar Nezami; Lambros S Athanasiou; Junedh M Amrute; Elazer R Edelman
Journal:  Am J Physiol Heart Circ Physiol       Date:  2018-08-10       Impact factor: 4.733

2.  Investigation of material modeling in fluid-structure interaction analysis of an idealized three-layered abdominal aorta: aneurysm initiation and fully developed aneurysms.

Authors:  Fatma Gulden Simsek; Young W Kwon
Journal:  J Biol Phys       Date:  2015-01-27       Impact factor: 1.365

3.  Patient-specific simulation of coronary artery pressure measurements: an in vivo three-dimensional validation study in humans.

Authors:  Panagiotis K Siogkas; Michail I Papafaklis; Antonis I Sakellarios; Kostas A Stefanou; Christos V Bourantas; Lambros S Athanasiou; Themis P Exarchos; Katerina K Naka; Lampros K Michalis; Oberdan Parodi; Dimitrios I Fotiadis
Journal:  Biomed Res Int       Date:  2015-03-01       Impact factor: 3.411

Review 4.  Structural modelling of the cardiovascular system.

Authors:  Benjamin Owen; Nicholas Bojdo; Andrey Jivkov; Bernard Keavney; Alistair Revell
Journal:  Biomech Model Mechanobiol       Date:  2018-06-18
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.